Comparative Study on the Quality of Robotic and Manual Dispensing in Intravenous Admixture Service
10.3870/j.issn.1004-0781.2025.04.026
- VernacularTitle:静脉用药调配中心配液机器人与传统人工配液质量对比探究
- Author:
Shoupeng WU
1
;
Zhendong NIU
;
Siting XIAO
;
Lin WANG
;
Yanbin SI
;
Zhigang ZHAO
Author Information
1. 首都医科大学附属北京天坛医院药学部,北京 100070
- Publication Type:Journal Article
- Keywords:
Intravenous drug dispensing;
Robotic liquid dispensing;
Manual mixing;
Quality analysis
- From:
Herald of Medicine
2025;44(4):668-672
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the quality of liquids dispensed by intelligent dispensing robot and traditional manual in PIVAS,to ensure the safety of clinical infusion.Methods Using omeprazole and ambroxol as the main drugs and 5%glucose injection and 0.9%sodium chloride solution as the solvent,a number of quality indexes including drug residues and the number of insoluble particles were evaluated in the two modes of manual and robotic dispensing,respectively.Results Under the robot dispensing mode and manual dispensing mode,the residual amount of drugs was less than 5%,the insoluble particles were far less than the limit,the pH value was in line with the human infusion range,and the endotoxin and aseptic culture were negative results,with no statistical significance(P>0.05).Conclusions The quality of liquid dispensed under the robotic dispensing mode is guaranteed,and there is no significant difference in the quality of liquid dispensed with the traditional manual dispensing mode,which provides a reliable guarantee for the large-scale application of robotic dispensing in intravenous admixture service.