MR Three-Dimensional Multi-Echo Ultrashort Echo Time Quantitative Technique in Differential Diagnosis in Benign and Malignant Pulmonary Nodules and Masses
10.3969/j.issn.1005-5185.2025.10.015
- VernacularTitle:磁共振三维多回波超短回波时间定量技术鉴别良恶性肺结节、肿块
- Author:
Heng LI
1
;
Wei WEI
;
Xiao YANG
;
Na ZHAO
;
Xiuzheng YUE
;
Yuedong HAN
Author Information
1. 西安高新医院放射科,陕西 西安 710075
- Publication Type:Journal Article
- Keywords:
Pulmonary nodules;
Pulmonary masses;
Magnetic resonance imaging;
Ultrashort echo time sequence;
Diagnosis,differential
- From:
Chinese Journal of Medical Imaging
2025;33(10):1115-1119
- CountryChina
- Language:Chinese
-
Abstract:
Purpose To explore the value of quantitative parameters(T2* value,R2* value)of three-dimensional multi-echo ultrashort echo time technique for the differential diagnosis of benign and malignant pulmonary nodules and masses(PNMs).Materials and Methods The MRI data of 68 patients with PNMs in Xi'an Gaoxin Hospital from July 2021 to October 2022 were retrospectively analyzed,and PNMs were grouped into benign(34 cases)and malignant(34 cases)categories using histopathology or clinical follow-up as the reference standard.Two observers respectively outlined the regions of interest on three-dimensional multi-echo ultrashort echo time-T2* and R2* maps,and quantitatively measured the T2* and R2* values.The intraclass correlation coefficient(ICC)was used to evaluate the consistency of the measured values.Differences in the above indicators between the two groups of PNMs were analyzed,and their diagnostic efficacy was assessed.The predictive probability of the combined two indicators was computed,the receiver operating characteristic curve was plotted,and the area under the curve(AUC)was calculated.Results The measurement results of each parameter of PNMs in the benign and malignant groups by the two observers were consistent(ICC>0.75).The T2* value of the malignant group was higher than that of the benign group(Z=-5.158,P<0.001),and the R2* value was lower than that of the benign group(Z=-4.845,P<0.001),and the differences were statistically significant.The AUC of the T2* value was 0.864(95%CI 0.775-0.953,P<0.001),with a maximum Youden index of 0.677,a threshold of 9.675 ms,a sensitivity of 76.5%,and a specificity of 91.2%.The AUC of the R2* value was 0.842(95%CI 0.746-0.937,P<0.001),with a maximum Youden index of 0.647,and a threshold of 109.15/s,with a sensitivity of 73.5%and a specificity of 91.2%.The AUC of the combined diagnosis of T2* and R2* values was 0.867(95%CI 0.779-0.955,P<0.001),with a maximum Youden index of 0.677,a sensitivity of 82.4%,and a specificity of 85.3%.There was no statistically significant difference in the pairwise comparison of T2* values,R2* values,and their combined AUC(all P>0.05).Conclusion The T2* value and R2* value of the three-dimensional multi-echo ultrashort echo time technique,as well as the combination of the two indicators,are all helpful in differentiating benign and malignant PNMs,providing imaging support for the preoperative non-invasive and precise differentiation of PNMs and optimizing clinical diagnosis and treatment decisions.