Develop an ICU nursing shift handover index based on ISBAR framework and create an intelligent platform for it
10.3969/j.issn.1671-8283.2025.09.009
- VernacularTitle:基于ISBAR理论的ICU护理交班指标构建及其智能化系统实现
- Author:
Lihui XU
1
;
Yan WU
;
Min CHI
;
Chunhua LUO
;
Fen CHEN
Author Information
1. 福建医科大学孟超肝胆医院重症医学科-外科,福建 福州,350007
- Publication Type:Journal Article
- Keywords:
ISBAR theory;
intensive care unit;
nursing shift handover;
index system;
intelligent system;
Delphi method
- From:
Modern Clinical Nursing
2025;24(9):66-75
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish an ICU nursing shift handover index based on the standardised communication framework of ISBAR(Identity,Situation,Background,Assessment,and Recommendation)and create an intelligent nursing shift handover system(hereinafter referred as"Smart ICU-ISBAR Nursing Shift Handover System"),thereby improving the standardisation,efficiency and quality of ICU nursing shift handovers with a standardised tool for planning ICU nursing shift handovers.Methods Literature was searched to identify the core elements of ISBAR and the key contents of ICU nursing shift handovers,then a preliminary draft of ICU nursing shift handover index was proposed.Delphi expert-consensus technique(20 experts)was used to screen and finalise the core dimensions and specific indicators of the index system,which were then integrated into the Smart ICU-ISBAR Nursing Handover System.Finally,the clinical effectiveness of the system was evaluated.Results Both Delphi rounds achieved 100.00%response rate.The expert authority coefficient was 0.83.The Kendall's W values of 2 rounds were 0.127 and 0.166(all P<0.001)respectively.The index importance scores ranged from 4.25-4.95 and 3.90-5.00,with coefficients of variation of 0.05-0.19 and 0.00-0.22,respectively.The final version of Smart ICU-ISBAR nursing shift handover system comprised 6 primary indicators and 60 secondary indicators.Over the clinical trials,the system achieved a 96.67%success rate in data-upload with an average response time of 1.80 sec.,the mean documentation time of shift handover at(1.97±0.58)min per patient,12 nurses'satisfaction with the shift handover quality of(4.47±0.25)and the rating of the system's usability of(4.75±0.08).The system was highly practical,convenient and intelligent.Conclusion The ICU nursing shift handover index system developed on the basis of ISBAR theory features a structural integrity,standardisation and ICU-specific characteristics and it is objective,scientific and rigorous.The Smart ICU-ISBAR Nursing Shift Handover System standardises the shift handover process,reduces information omissions,and improves efficiency and quality of nursing shift handover process.It serves as a standardised shift handover tool for ICU nursing shifts.