Construction and application of the user-centered design intelligent interactive insulin pump information management system
10.3760/cma.j.cn211501-20240201-00278
- VernacularTitle:以用户为中心的智能交互式胰岛素泵信息管理系统的构建及应用
- Author:
Yujiao SUN
1
;
Ning ZHANG
;
Hongmei ZHANG
;
Cheng JI
;
Yan JIN
;
Lili SHEN
;
Yi LU
Author Information
1. 南京大学医学院附属鼓楼医院内分泌科,南京 210008
- Publication Type:Journal Article
- Keywords:
Information system;
Insulin pump;
User-centered design
- From:
Chinese Journal of Practical Nursing
2024;40(36):2856-2863
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To construct a user-centered intelligent interactive insulin pump information management system and verify its clinical application effects, providing more efficient and convenient blood glucose management support for medical staff.Methods:This study was divided into a retrospective cohort study and a cross-sectional survey study. Using purposive sampling, 152 patients using insulin pumps in the non-endocrinology department of Drum Tower Hospital Affiliated to Nanjing University Medical School from September to December 2021 were set as the control group, and 209 patients using insulin pumps in the same department from September to December 2022 were set as the experimental group. The control group was given insulin pump management based on the mode of the blood glucose management in hospital, while the experimental group, in addition to the insulin pump management based on the mode of blood glucose management in hospital, used a user-centered intelligent interactive insulin pump information management system. The incidence of adverse events related to insulin pumps in non-endocrinology department and the standardization rate of insulin pump documentation records were compared between the control group and the experimental group. In December 2022, 119 system users were surveyed using convenience sampling to evaluate the effectiveness of the insulin pump information system.Results:In the control group, there were 89 males,63 females, aged (58.15 ± 7.89) years.In the experimental group,there were 113 males,96 females, aged (58.72 ± 8.93)years. The incidence of adverse events related to insulin pumps was 1.48% (13/879) in the control group and 0.34%(4/1 182) in the experimental group, the difference was statistically significant ( χ2=8.02, P<0.05). The standardization rate of insulin pump paperwork in the experimental group was 90.1% (190/209), which was higher than that 48.02% (73/152) in the control group, the difference was statistically significant ( χ2=81.82, P<0.05). The average scores of each item in the system effectiveness evaluation questionnaire were all higher than the median of 2.5. Conclusions:The application of the user-centered intelligent interactive insulin pump information management system can reduce the incidence of adverse events related to insulin pumps, improve the standardization rate of insulin pump nursing documentation, and users are satisfied with the effectiveness evaluation of the system.