Optimal b-Value Sets Based on Intravoxel Incoherent Motion in Pulmonary Solid Benign and Malignant Lesions
10.3969/j.issn.1005-5185.2025.08.007
- VernacularTitle:基于体素内不相干运动分析肺实性良恶性病变最佳b值
- Author:
Wei WEI
1
;
Heng LI
;
Na ZHAO
;
Chanjuan YU
;
Xiuzheng YUE
;
Zhiwei SHEN
;
Xiangfei CHEN
;
Sheng ZHANG
;
Xiao YANG
;
Yuedong HAN
Author Information
1. 西安高新医院放射科,陕西 西安 710075
- Publication Type:Journal Article
- Keywords:
Lung solid lesion;
Diffusion weighted imaging;
Mono diffusion-weighted imaging model;
Biexponential diffusion-weighted imaging model;
Best sets of b values;
Diagnosis,differential
- From:
Chinese Journal of Medical Imaging
2025;33(8):834-839
- CountryChina
- Language:Chinese
-
Abstract:
Purpose To quantitatively compare the diffusion parameters of mono-and biexponential diffusion-weighted imaging models,and to obtain optimal sets of b-values in diffusion-weighted MRI for obtaining monoexponential apparent diffusion coefficient(ADC)close to perfusion-insensitive intravoxel incoherent motion(IVIM)model ADC(ADCIVIM)in identifying of pulmonary solid benign and malignant lesions.Materials and Methods IVIM was performed in 40 patients with solid nodule and masse in Xi'an Gaoxin Hospital from July 2021 to August 2022 using a 3.0T MR imager.Two experienced diagnostic radiologists subjectively evaluated the IVIM images.A single index model was used to calculate ADC values(ADC0-1 000,ADC20-1 000,ADC50-1 000,ADC80-1 000,ADC150-1 000,ADC300-1 000,ADC500-1 000,ADC300,500,1 000,ADC300,800,1 000,ADC300,500,ADC300,800 and ADC300,1 000).The reference standard ADCIVIM value were calculated using a double-exponential model.The physician's measurements between two physicians were measured.The malignant and benign groups were compared and receiver operator characteristic curve for all parameters were analyzed.Results The measurement consistency of ADC values under b value sets and ADCIVIM was very good,and the intraclass correlation coefficient was more significant than 0.75.The differences between ADCIVIM and ADC values in each b group were statistically significant(t=-6.016--2.500,all P<0.05).The area under the curve(AUC)of ADCIVIM was the largest(0.906),with an optimal threshold of 1.271×10-3 mm2/s,a sensitivity of 80.0%and a specificity of 93.0%.The diagnostic efficacy close to ADCIVIM were ADC300,800(AUC=0.891),ADC50-1 000(AUC=0.827)and ADC300,800,1 000(AUC=0.795),respectively.The optimal threshold of ADC300,800 was 1.140×10-3 mm2/s,the sensitivity and specificity were 80.0%and 93.7%,respectively.Conclusion Combining b-values 300 s/mm2 and 800 s/mm2 is recommended as routine scanning parameters for identifying the insensitive monoexponential ADC between benign and malignant solid pulmonary lesions.