Clinical value of right-sided overlap and single-flap valvuloplasty in Da Vinci robotic proximal gastrectomy
10.3760/cma.j.cn115610-20250310-00094
- VernacularTitle:达芬奇机器人手术系统近端胃切除术中食管胃右开襟单肌瓣吻合的临床价值
- Author:
Haixiao FU
1
;
Wei FU
;
Xuan ZHANG
;
Tengteng LI
;
Hao LIU
;
Xu SUN
;
Wei LIU
;
Shuaiwei CHEN
;
Yongyou WU
;
Kai WANG
Author Information
1. 徐州医科大学附属医院胃肠外科,徐州 221006
- Publication Type:Journal Article
- Keywords:
Stomach neoplasms;
Gastroesophageal junction cancer;
Proximal gastrec-tomy;
Da Vinci robotic surgery;
Right-sided overlap and single-flap valvulo-plasty;
S
- From:
Chinese Journal of Digestive Surgery
2025;24(4):528-534
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the clinical value of right-sided overlap and single-flap valvuloplasty (ROSF) in Da Vinci robotic proximal gastrectomy.Methods:The retrospective and descriptive study was conducted. The clinicopathological data of 12 patients who underwent ROSF in Da Vinci robotic proximal gastrectomy at The Affiliated Hospital of Xuzhou Medical University from September 2023 to May 2024 were collected. There were 7 males and 5 females, aged 62(range, 35?75)years. Observation indicators: (1) surgical conditions; (2) postoperative pathological results; (3) follow-up. Measurement data with normal distribution were represented as Mean± SD, and mea-surement data with skewed distribution were represented as M(range). Count data were expressed as absolute numbers. Results:(1) Surgical conditions. All patients successfully completed the surgery, without conversion to laparotomy. The operation time of 12 patients was (236±24)minutes. The time of single-layer fabrication and anastomosis was (105±28)minutes. The volume of intra-operative blood loss was (36±19)mL. Time to postoperative first fluid food intake was (3.5±1.1)days. The amylase levels in the abdominal drainage fluid on postoperative days 1, 2, and 3 were (321±121)U/L, (225±97)U/L, and (85±22)U/L, respectively. Time to postoperative drainage tube removal was (5.3±1.5)days. Duration of postoperative hospital stay was (7.6±1.1)days. All 12 patients had no anasto-motic related complications such as anastomotic leakage, anastomotic bleeding, anastomotic stenosis, and had no functional complications such as gastric emptying disorders or gastroesophageal reflux after surgery. (2) Postoperative pathological results. The distance of the proximal tumor margin of the 12 patients was (1.8±1.1)cm. The distance of distal margin was (5.7±2.1)cm. Number of lymph node dissected was 31.0(range, 22.0?45.0). Number of positive lymph node dissected was 3.4±2.4. Number of lymph node dissected from the pancreatic superior margin was 14.7±4.3. Results of postoperative pathological examination in the 12 patients showed 8 cases of Ⅰ stage, 3 cases of Ⅱ stage, 1 case of Ⅲ stage of the TNM staging. (3) Follow-up. All 12 patients were followed up for 6 (range, 3?24)months. During the follow-up period, all 12 patients had no local tumor recurrence or distant metastasis. All 12 patients had no complications such as anastomotic leakage, anastomotic bleeding, or anastomotic stenosis, and did not experience symptoms of gastroesophageal reflux such as heartburn or vomiting.Conclusion:The ROSF in Da Vinic robotic proximal gastrectomy is safe and feasible.