The effect of different doses of butolphinol on levels of serum prolactin, serotonin and lipid hydrogen peroxide after cesarean section
10.3760/cma.j.cn115455-20240817-00715
- VernacularTitle:不同剂量布托啡诺对剖宫产术后产妇血清催乳素、5-羟色胺及脂质过氧化氢水平的影响
- Author:
Yongning ZHU
1
;
Danni XU
;
Shuang YANG
;
Ning XIE
;
Na XIAN
;
Zhi JIA
Author Information
1. 济宁医学院附属医院产科,济宁 272100
- Publication Type:Journal Article
- Keywords:
Cesarean section;
Analgesia, patient-controlled;
Butorphanol;
Prolactin;
Serotonin;
Lipid hydrogen peroxide
- From:
Chinese Journal of Postgraduates of Medicine
2025;48(6):510-515
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the effects of different doses of butorphanol on prolactin, serotonin and lipid hydrogen peroxide after cesarean section.Methods:A total of 124 women who underwent cesarean section in the Affiliated Hospital of Jining Medical University from January 2023 to January 2024 were prospectatively selected as study subjects, and divided into the study group 1 (41 cases), study group 2 (41 cases) and study group 3 (42 cases) according to random number table method. All three groups underwent patient-controlled analgesia after surgery, and 0.2 mg fentanyl was used as analgesic drug. However, the doses of butorphanol were 100 mg/L in the study group 1, 120 mg/L in the study group 2, and 140 mg/L in the study group 3. The level of PRL and first lactation time before and after surgery were compared among the three groups at different time points, serotonin and LHP levels were compared among the three groups at different time points after surgery, Ramsay and visual analog scale (VAS) scores were compared among the three groups at different time points after surgery, and the occurrence of adverse reactions and satisfaction with analgesic effect were compared among the three groups.Results:At 24, 48 and 72 h after operation, the level of PRL in the study group 3 was higher than that in the study group 2 and study group 1: (383.02 ± 47.57) μg/L vs. (376.39 ± 46.83), (302.88 ± 41.38) μg/L; (412.38 ± 40.22) μg/L vs. (394.82 ± 38.30), (315.09 ± 37.93) μg/L; (434.39 ± 39.39) μg/L vs. (427.48 ± 40.27), (344.39 ± 42.78) μg/L, there were statistical differences ( P<0.05). The first lactation time in the study group 2 and study group 3 was lower than that in the study group 1: (50.31 ± 6.52), (49.54 ± 6.27) h vs. (53.91 ± 8.42) h, there was statistical difference ( P<0.05). At 2 h (T 1), 12 h (T 2), 24 h (T 3) and 48 h (T 4) after surgery, the levels of serotonin in the study group 3, study group 2 and study group 1 were increased successively, and the levels of LHP were decreased successively, there were statistical differences ( P<0.05). At 30 min after surgery (T 0), T 1, T 2, T 3 and T 4, the Ramsay score in the study group 3, study group 2 and study group 1 were increased successively, and the VAS score were decreased successively, there were statistical differences ( P<0.05). There was no significant difference in the incidence of adverse reactions among the three groups ( P>0.05). The total satisfaction of study group 3 was higher than that of study group 2 and study group 1: 92.86%(39/42) vs. 73.17%(30/41), 68.29%(28/41), there was statistical difference ( Z = 2.52, P = 0.008). Conclusions:Butorphanol 140 mg/L has a more significant analgesic effect after cesarean section, and can improve the levels of serum PRL, serotonin and LHP, reduce the occurrence of adverse reactions, and improve the satisfaction of analgesia