Feasibility study of"four low"protocol based on body weight in coronary CT angiography
10.3969/j.issn.1002-1671.2025.04.030
- VernacularTitle:基于体质量的"四低"技术在冠状动脉CT血管成像中的可行性研究
- Author:
Hui ZHANG
1
;
Yongmeng ZHU
1
;
Jiahao CHEN
1
;
Jie XU
1
;
Qingshan CHENG
1
Author Information
1. 宁波大学附属第一医院放射科,浙江 宁波 315010
- Publication Type:Journal Article
- Keywords:
threshold;
dynamic volume;
coronary computed tomography angiography
- From:
Journal of Practical Radiology
2025;41(4):673-677
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the feasibility of protocol with low tube voltage,low contrast agent dose,low injection rate,and low trigger threshold based on body weight in coronary computed tomography angiography(CCTA).Methods Patients suspected with coronary heart disease who underwent 320 rows of CCTA were prospectively selected.They were divided into 4 groups:<60 kg,60-70 kg,71-80 kg,>80 kg based on different body weights,120 cases for each group,then were randomly divided into experimental group and control group using a random number table method,with 60 patients in each group.Each case in the control group had a tube voltage of 120 kV and a trigger threshold of 240 HU;each case in the experimental group had a tube voltage of 100 kV and a trigger threshold of 190 HU.According to the CCTA application guidelines,the iodine flow rate was used to determine the contrast agent injection rate in the control group,while the injection rate in the experimental group was reduced by 30%.Using an injection time of 12 s,the control group's contrast agent dose was obtained,and that of the experimental group decreased by 30%.Two radiologists evaluated the CT values,contrast-to-noise ratio(CNR),image quality score,and signal-to-noise ratio(SNR)of the middle segment of the right coronary artery,proximal segment of the left anterior descending branch,and proximal segment of the left circumflex branch,as well as compared the effective dose(ED)of volume scanning and threshold monitoring sequences.One-way ANOVA,independent sample t-test,and Mann-Whitney U-test were used to evaluate the differences in each parameter.Results There were no statistically significant differences in general information and subjective image scores between the experimental group and the control group(P>0.05).There were no statistically significant differences in CT values,CNR,and SNR between the experimental group and the control group at different body weights for the middle segment of the right coronary artery,the proximal segment of the left anterior descending branch,and the proximal segment of the left circumflex branch(P>0.05).In terms of radiation dose,the comparison between the control group and the experimental group at the same body weights showed statistically significant differences both in volume scanning and threshold monitoring sequences(P<0.001),and the ED of the experimental group was significantly lower than that of the control group.Conclusion The protocol with low tube voltage,low contrast agent dose,low injection rate,and low trigger threshold determined based on different body weights can achieve satisfactory image quality for CCTA,while significantly reducing the radiation dose of volume scanning and threshold monitoring sequences.