Clinical application of improved treatment of the free margin of the leaflet in aortic root remodeling procedure
10.3760/cma.j.cn112139-20240816-00377
- VernacularTitle:主动脉根部重塑术瓣叶游离缘处理方法的改进与临床应用效果分析
- Author:
Xinjin LUO
1
;
Shaoye WANG
1
;
Juntao QIU
1
;
Xuanshu LI
1
;
Peng ZHANG
1
;
Yuetang WANG
1
;
Cuntao YU
1
Author Information
1. 中国医学科学院 北京协和医学院 阜外医院心血管外科,北京 100037
- Publication Type:Journal Article
- Keywords:
Aortic diseases;
Aortic valve;
Aortic root aneurysm;
Valve preservation
- From:
Chinese Journal of Surgery
2025;63(7):618-623
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the feasibility and clinical outcome of estimating the target length of the free margin of the leaflet by diameter of the prosthesis graft used to reconstruct the aortic root during the modified root remodeling procedure.Methods:This is a retrospective case series study. The clinical data of 11 patients with aortic root aneurysm who underwent modified aortic root remodeling procedure with external sub-valvular ring from July 2021 to May 2024 at Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College were analyzed. The age of the patients was (42.3±14.4) years (range:23 to 61 years), including 9 males and 2 females. The aortic valve of all patients was tri-leaflet configuration. Marfan syndrome was diagnosed in 3 cases. The diameter of the prosthesis graft was determined according to the Lansac group′s criteria based on the diameter of the aortic annulus, and a graft ring of the same diameter was used as the external sub-valvular ring. The free margin of the leaflet was treated with central plication according to the standard of “target length of free margin of the leaflet=the diameter of the selected graft+3 to 5 mm”. The surgical results and postoperative aortic valve closure function were observed.Results:All 11 patients successfully completed the operation without in-hospital death or complications. The graft with a diameter of 28 mm were used in 7 cases, 26 mm in 3 cases, and 30 mm in 1 case. 4 patients required central plication of the free margin of 3 leaflets, 2 patients required treatment of 2 leaflets, 3 patients required treatment of 1 leaflet, and 2 patients did not need treatment of the free margin of the leaflets. The functional status of aortic valve closure was significantly improved in all patients after surgery, and the degree of residual aortic regurgitation was not more than mild. After reconstruction of the aortic root, the measured effective height was (8.8±1.3) mm (range:7 to 11 mm) and the measured coaptation length was (5.2±0.9) mm (range:4 to 7 mm). All patients were re-examined 3 months after surgery. Echocardiography showed that the degree of aortic regurgitation was mild or lower, and the left ventricular end-diastolic diameter was (49.4±6.1) mm (range: 36 to 56 mm), which was smaller than that before the operation ((58.5±7.0) mm (range: 47 to 72 mm)). Eight patients were followed up for more than 6 months, and 5 patients were followed up for more than 1 year. The degree of aortic regurgitation in these patients was mild or below.Conclusions:The method based on the diameter of the selected prosthesis graft to deal with the length of the free margin of the leaflet can be effectively used in the modified aortic root remodeling procedure with external sub-valvular ring. The early postoperative results are satisfactory .