Impact of the Micra AV Leadless Pacemaker on Cardiac Function:a Real-world Study
10.3969/j.issn.1000-3614.2025.07.003
- VernacularTitle:Micra AV无导线心脏起搏器对心功能影响的真实世界研究
- Author:
Yalan DENG
1
;
Wenqi PAN
1
;
Yue WEI
1
;
Yangyang BAO
1
;
Yun XIE
1
;
Changjian LIN
1
;
Ning ZHANG
1
;
Qi JIN
1
;
Tianyou LING
1
;
Liqun WU
1
Author Information
1. 上海交通大学医学院附属瑞金医院 心内科,上海 200025
- Publication Type:Journal Article
- Keywords:
leadless pacemaker;
Micra AV;
cardiac function;
left ventricular ejection fraction;
atrioventricular synchrony
- From:
Chinese Circulation Journal
2025;40(7):653-658
- CountryChina
- Language:Chinese
-
Abstract:
Objectives:To investigate the impact of the Micra AV leadless pacemaker on cardiac function.Methods:A total of 76 patients who received the implantation of Micra AV leadless pacemaker due to sick sinus syndrome or atrioventricular block at Ruijin Hospital,Shanghai Jiao Tong University School of Medicine from September 2022 to April 2023 were included in this study.Among them,26 patients(34.2%)had sick sinus syndrome,and 50 patients(65.8%)had atrioventricular block.The patients were followed up for 1 year postoperatively.Cardiac function was evaluated by echocardiography,and the parameters of the pacemaker were collected through the outpatient clinic programming system.Results:After a follow-up of 120(87,181)days,compared with the preoperative state,the left ventricular ejection fraction(LVEF)decreased postoperatively([66.6±5.6]%vs.[63.8±5.2]%,P<0.001),and the cardiac output increased[(4.3±1.2)L/min vs.(5.3±1.5)L/min,P<0.001].There were no statistically significant differences in various cardiac function indexes of patients with sick sinus syndrome between the postoperative and preoperative states(all P>0.05).Compared with the preoperative state,in patients with atrioventricular block,the LVEF decreased postoperatively([67.0±5.1]%vs.[63.4±4.4]%,P<0.001),the cardiac output increased([4.2±1.1]L/min vs.[5.2±1.2]L/min,P<0.001),and the left ventricular end-diastolic diameter decreased[(49.9±5.4)mm vs.(48.6±5.0)mm,P=0.044].Firth's logistic regression analysis indicated that the preoperative LVEF(for every 1%increase,OR=1.56,95%CI:1.12-2.17,P=0.001),stroke volume(for every 1 ml increase,OR=1.15,95%CI:1.04-1.28,P=0.001),body mass index(for every 1 kg/m2 increase,OR=1.49,95%CI:1.02-2.17,P=0.020),and hypertension(OR=12.71,95%CI:1.11-145.13,P=0.039)were independent risk factors for the decrease in LVEF after surgery in patients with atrioventricular block.After the implantation of the MciraTM AV leadless pacemaker,the overall atrioventricular synchrony rate was 81.2%(68.8%,89.0%).The atrioventricular synchrony rates of patients with sick sinus syndrome and those with atrioventricular block were 70.6%(59.5%,83.4%)and 82.4%(74.2%,89.3%)respectively(P<0.05).Firth's logistic regression analysis indicated that sick sinus syndrome(OR=0.26,95%CI:0.07-0.89,P=0.029)and preoperative LVEF(for every 1%increase,OR=1.18,95%CI:1.03-1.35,P=0.015)were independent predictive factors for the atrioventricular synchrony rate>80%.Conclusions:There are differences in the impacts of the Micra AV leadless pacemaker on the LVEF and atrioventricular synchrony rate between patients with sick sinus syndrome and those with atrioventricular block.The preoperative LVEF,stroke volume,body mass index,and hypertension have independent predictive effects on the decrease in postoperative LVEF in patients with atrioventricular block.Sick sinus syndrome and preoperative LVEF are independent predictive factors for the atrioventricular synchrony rate>80%after surgery.