Simulation of explosion damage of medical cabins in various ships
10.19745/j.1003-8868.2025005
- VernacularTitle:多种舰艇的医疗卫生舱室爆炸损伤模拟研究
- Author:
Yun-xia CHENG
1
;
Meng-lei JIA
;
Yan LI
;
Zun-feng DU
;
Chen-guang HAN
Author Information
1. 天津中医药大学管理学院,天津 301617
- Publication Type:Journal Article
- Keywords:
ship;
medical cabin;
explosion damage;
simulation;
explosion load
- From:
Chinese Medical Equipment Journal
2025;46(1):27-32
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the damage results and structural response laws of medical cabins in ships under explosion attack.Methods Firstly,the cabin structure was equivalently regarded as a T-shaped plate frame based on the explosion load theory,then four finite element models for the medical cabins were established with the dimensions(length ×width×height)of 2.8 m×2.6 m×2.3 m,3.2 m×3.2 m×2.4 m,4.2 m×3.2 m×2.5 m and 5.4 m×4.0 m×2.6 m.Secondly,an explosion damage model was constructed using ABAQUS simulation software,and explosion damage simulation was carried out with the explosion locating at the cabin center and the outside of the bulkhead and the explosion energy of 10 kg and 100 kg trinitrotoluene(TNT)equivalent.Finally,the 10 kg and 100 kg TNT explosion damage results were ananlyzed at the cabin center and the outside of the bulkhead.Results At the cabin center,10 kg TNT explosion resulted in local deformation and limited affected area of the large-sized cabin,while 100 kg TNT explosion lead to extensive affected ranges in the functional areas and severe deformation and damage in the small-sized cabin.At the outside of the bulkhead,10 kg TNT explosion gave rise to breaches in some areas of the small-sized cabin and local deformation of the large-sized cabin,while 100 kg TNT explosion caused large breaches in all the cabins.Conclusion The explosion load induces serious deformation and damage and complicated breaches in the cabin with small size and weak structural strength.The cabin with large size and thick bulkhead and stiffener behaves well in explosion resistance,while high equivalent explosions may bring about serious damage to its local structure.[Chinese Medical Equipment Journal,2025,46(1):27-32]