Results of physiological experiments using a home-made high performance human centrifuge
10.3760/cma.j.cn113854-20250121-00012
- VernacularTitle:某型国产高性能载人离心机生理试验结果分析与探讨
- Author:
Minghao YANG
1
;
Lihui ZHANG
1
;
Cong WANG
1
;
Ke JIANG
1
;
Haixia WANG
1
;
Xiaoyang WEI
1
;
Yi WANG
1
;
Xiaoxue ZHANG
1
;
Jie YU
1
;
Zhao JIN
1
Author Information
1. 空军军医大学空军特色医学中心加速度生理研究室,北京 100142
- Publication Type:Journal Article
- Keywords:
Acceleration;
Centrifuge;
Closed-loop mode;
Pre-programed mode
- From:
Chinese Journal of Aerospace Medicine
2025;36(3):182-187
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To find out whether the performance of a China-made high performance human centrifuge can satisfy the need of high G training by conducting physiological experiments.Methods:The dynamic physical performance of the anti-G equipment with the human centrifuge was tested before 5 subjects underwent the gradual-onset rate (GOR) run and rapid onset rate (ROR) run experiments. The G onset rate of GOR was 0.1 G/s. The relaxed G-tolerance under GOR (GOR tolerance 1) and the anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) were tested respectively. The G onset rate of ROR was 3 G/s, and the closed-loop mode and pre-programed mode were employed respectively. The closed-loop mode involved 5 G 10 s and 8 G 10 s, where the subjects were required to manipulate the joystick to ensure that the real-time curve of the load matched the target curve. In the pre-programmed mode, the subjects were exposed to 8 G 10 s passively, without any operation requirements. A subjective evaluation form was filled out by subjects after the experiments, in which the 14 indexes for evaluation were about the gondola facilities and environment, running processes, medical monitoring and overall assessment.Results:Both the oxygen mask and anti-G suit achieved full pressurization within 2.0 s. The GOR tolerance 1 was [4.0(3.8, 4.6)] G while the GOR tolerance 2 was (6.2±0.5) G, suggesting a statistically significant difference ( Z=-2.63, P=0.008). The HP anti-G straining maneuver effect was (2.0±0.6) G. All the 5 subjects finished the 5 G 10 s experiment in a closed-loop mode. Three of them attempted 8 G 10 s in the closed-loop mode (1 subject achieved only 7.6 G peak acceleration, and the other 2 achieved full 8 G 10 s exposure), while the remaining 2 completed the 8 G 10 s in the pre-programmed mode. In the closed-loop mode, it was found that the stick force was too strong, the guiding G and real time G curve were not easy to distinguish for some of the subjects because the curve colors were similar, and that the subjects could not see the G curves clearly in case of a grayout. Both seat comfort and the voice quality of communication got the highest subjective assessment score [5.0(4.0, 5.0)] while the sensation of tumble got the lowest score (2.8±0.8). The median or mean scores of other subjective evaluation indexes ranged from 3.0 to 4.6 points. The overall score of subjective assessment was [4.0(3.5, 4.0)] points. Conclusions:The China-made high performance human centrifuge can meet the requirements of 8.0 G high G training, which can be made more effective and comfortable if the strong stick force and feeling of tumble during stop running are overcome.