Diagnostic value of fat content measurement by magnetic resonance multi-echo Dixon technique combined with serological indicators for early liver fibrosis
10.11659/jjssx.03E024058
- VernacularTitle:磁共振多回波Dixon技术脂肪含量测量联合血清学指标对早期肝纤维化的诊断价值
- Author:
Qin-qin HU
1
;
Hua YANG
;
Jia-fei CHEN
;
Xiao-fei HU
;
Jie WANG
;
Hui-min LIU
Author Information
1. 重庆市中医院放射科,重庆 400021
- Publication Type:Journal Article
- Keywords:
ME-Dixon technique;
hepatic fat fraction;
serological indicators;
early liver fibrosis
- From:
Journal of Regional Anatomy and Operative Surgery
2025;34(3):245-249
- CountryChina
- Language:Chinese
-
Abstract:
Objective To analyze the diagnostic value of fat content measurement based on magnetic resonance multi-echo Dixon(ME-Dixon)technique combined with serological indicators for early liver fibrosis.Methods A total of 78 patients with early liver fibrosis who underwent liver biopsy at the First Affiliated Hospital of Army Medical University from August 2019 to October 2021 were included.According to the pathological results,the patients with early liver fibrosis were divided into the S0 group(n=21),the S1 group(n=32),and the S2 group(n=25).Meanwhile,the complete imaging examination results(including ME-Dixon sequence)and laboratory examination results[including hyaluronic acid(HA),procollagen Ⅲ(PCⅢ),collagen Ⅳ(CⅣ),laminin(LN),aspartate transaminase(AST),alanine amino-transferase(ALT),gamma-glutamyl transferase(GGT),alkaline phosphatase(ALP)]were collected.And the hepatic fat fraction(HFF)was measured by ME-Dixon technique.One-way ANOVA was used to analyze the differences in HFF and serological indicators among the three groups,and then factors with statistical differences in the univariate analysis were selected to draw receiver operating characteristic(ROC)curve,and the area under the curve(AUC)was calculated to evaluate their value in the diagnosis of liver fibrosis and the degree of early liver fibrosis.Results There was no statistically significant difference in the PCⅢ,LN,AST,or ALT among the S0,S1,and S2 groups(P>0.05),while there were statistically significant differences in the HFF,HA,CⅣ,GGT,and ALP(P<0.05),and the levels of HA,CⅣ,GGT,and ALP in the S2 group were significantly higher than those in the S0 and S1 groups(P<0.05).ROC curve analysis showed that the above indicators for diagnosing liver fibrosis and the degree of early liver fibrosis based on AUC values were in the following order:HFF+GGT(0.72)>HFF(0.68)>GGT(0.61)>CⅣ(0.54)>ALP(0.53)>HA(0.48)and HA+CⅣ(0.71)>CⅣ(0.68)>HA(0.66)>GGT(0.61)>ALP(0.59)>HFF(0.46).Conclusion The fat content measurement based on magnetic resonance ME-Dixon tech-nique combined with serological indicators has significant reference value for the diagnosis of early liver fibrosis,and it plays a certain guid-ing role in clinical diagnosis and treatment.