Efficacy of free medial sural artery perforator flap transplantation in repairing electrical burn wounds on hands and feet
10.3760/cma.j.cn501225-20240611-00226
- VernacularTitle:腓肠内侧动脉穿支皮瓣游离移植修复手足电烧伤创面的效果
- Author:
Weidong ZHANG
1
;
Wei ZHANG
1
;
Gang YU
1
;
Lan CHEN
1
;
Xiang GONG
1
;
Weiguo XIE
1
;
Tianfeng RU
1
Author Information
1. 武汉大学同仁医院暨武汉市第三医院烧伤科,武汉 430060
- Publication Type:Journal Article
- Keywords:
Burns, electric;
Microsurgery;
Surgical flaps;
Medial sural artery perforator flap;
Wounds on hands and feet;
Free flap;
Wound repair
- From:
Chinese Journal of Burns
2025;41(4):386-393
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the efficacy of free medial sural artery perforator flap transplantation in repairing electrical burn wounds on hands and feet.Methods:This study was a retrospective observational study. From November 2017 to September 2023, 21 male patients aged 28-51 years with electrical burns on hands and feet who met the inclusion criteria were admitted to Tongren Hospital of Wuhan University & Wuhan Third Hospital. There were 23 wounds, of which 14 were on the hand and 9 on the foot; 9 were associated with exposed tendon injury, 6 were associated with bone exposure or necrosis, and 8 were associated with joint injury. The wound area after debridement was 4.0 cm×2.5 cm-14.0 cm×10.0 cm. For 2 relatively wide wounds and 2 adjacent fingers/toes wounds, the lobulated flaps centered on 2 medial sural artery perforators were designed and incised for repair. For other wounds, medial sural artery perforator flaps were designed and incised. The flap area was 5.0 cm×3.0 cm-16.0 cm×11.0 cm. The arteriovenous vessels of flap were anastomosed end-to-end with the arteriovenous vessels of the recipient area; the cutaneous nerves of 10 flaps were anastomosed with the nerves in hand wound, and the sural nerve bundle was cut to repair one digital nerve defect. The donor site wound was closed with tension-relieving sutures. Postoperative flap survival and wound healing at donor site were recorded. During follow-up, subsequent flap revision was recorded, the texture and appearance of the flap, as well as the scarring and functional recovery of the donor area of the lower leg, were observed. At the last follow-up, the recovery of hand flap sensation was observed, the satisfaction of patients with the treatment effect of each operation was investigated by using Likert scale, the hand function of the affected hand in patients with hand wounds was evaluated by using the trial standards for evaluation of partial function of upper extremity by the Hand Surgery Society of Chinese Medical Association, and the weight-bearing walking ability of the affected foot in patients with foot wounds was evaluated by Holden walking ability grading.Results:There was a slight necrosis at the distal end of one flap after surgery, which healed after dressing change. All 23 flaps survived. The sutures of the two donor areas were poorly healed due to high local tension, and the second sutures were performed after debridement and drainage, and the healing was good. The wounds of the remaining 21 donor sites healed well. Follow-up of 6-26 months after surgery showed that 3 flaps were slightly bloated, and the appearance was improved after flap reconstruction; the other flaps did not undergo subsequent revision. All flaps were soft and similar to the surrounding tissue morphology. Linear scar remained in the donor site of the lower leg, and walking function was normal. At the last follow-up, the protective sensation of the hand flap was restored; the patients were very satisfied with the results of 21 surgeries and were relatively satisfied with the results of 2 surgeries. Among the 14 patients with hand wounds, the affected hand function was rated as excellent in 10 cases, very good in 3 cases, and acceptable in one case, and the weight-bearing walking ability of the affected foot in 7 patients with foot wounds was all rated as grade Ⅴ.Conclusions:The medial sural artery perforator flap has the advantages of reliable blood supply, appropriate thickness and smoothness, and can be lobulated or cut according to the shape of the wound. The flap demonstrates superior aesthetic and functional restoration in repairing electrical burn wounds on hands and feet, achieving high patient satisfaction with the surgical treatment effect.