Multimodal ultrasound of the testis in differentiating subtypes of spermatogenic dysfunction:a preliminary study
10.3760/cma.j.cn131148-20250517-00279
- VernacularTitle:睾丸多模态超声鉴别精子发生障碍亚型的初步探讨
- Author:
Tingting LEI
1
;
Gaoxiang FAN
;
Penglin ZOU
;
Chao JIA
;
Hongmei LIANG
;
Jun LIN
;
Rong WU
;
Lianfang DU
;
Zheng LI
;
Qiusheng SHI
Author Information
1. 南京医科大学附属上海一院超声科,上海 200080
- Publication Type:Journal Article
- Keywords:
Spermatogenesis dysfunction;
Multimodal ultrasound;
Shear wave elastography;
Contrast-enhanced ultrasound;
Microdissection testicular sperm extraction
- From:
Chinese Journal of Ultrasonography
2025;34(8):678-685
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To analyze the imaging features of testicular conventional ultrasonography(US),shear wave elastography(SWE),and contrast-enhanced ultrasonography(CEUS)in subtypes of spermatogenic dysfunction(focal,arrest,and exhausted),and to evaluate the diagnostic efficacy of testicular multimodal ultrasound.Methods:A prospective study enrolled 310 spermatogenic dysfunction patients(focal type group: n=77,arrest type group: n=20,exhaustive type group: n=213)and 30 healthy volunteers(control group)at Shanghai General Hospital between October 2023 and December 2024. All patients underwent preoperative testicular US,SWE,and CEUS examinations,followed by microdissection testicular sperm extraction. Ultrasound parameters were compared among groups,and receiver operating characteristic(ROC)curves were plotted to assess the diagnostic efficacy of multimodal ultrasound for different subtypes. Results:①Testicular volume:The arrest group exhibited significantly greater volume compared to the focal group and the exhausted group(all P<0.05). No statistically significant difference was observed between the arrest group and the normal group( P>0.05). ②Mean Young's modulus(Emean):The arrest group exhibited significantly lower Emean compared with both the focal and exhausted groups(all P<0.05),but showed no significant difference versus the normal group( P>0.05). ③CEUS quantitative parameters:The arrival time(AT)and time to peak(TTP)in the exhausted group were higher than those in the normal group,while the peak intensity(PI)and area under the time-intensity curve(AUC)were lower(all P<0.05). No significant differences were found in AT,TTP,or AUC among the three spermatogenic dysfunction subgroups(all P>0.05). ④CEUS perfusion patterns:The focal group predominantly exhibited a mottled pattern(70.13%,54/77). Both the arrest group(90.00%,18/20)and the normal group(93.33%,28/30)predominantly exhibited an rich pattern. The exhausted group predominantly exhibited a sparse pattern(56.34%,120/213). ⑤ROC curve analysis showed that for differentiating the arrest group from the focal type group and the exhaustive type group,the combination of Emean,testicular volume,and CEUS perfusion pattern yielded an AUC of 0.931,with a sensitivity of 95.00% and specificity of 85.86%. For differentiating the focal type group from the exhaustive type group,the combination of testicular echogenicity,CEUS perfusion pattern,and Emean yielded an AUC of 0.833,with a sensitivity of 81.82% and specificity of 75.12%. Conclusions:Multimodal ultrasonography can comprehensively characterize the imaging features of different subtypes of spermatogenic dysfunction,holding promise as a noninvasive predictive tool.