Current status of water management for terminal rinsing of digestive endoscope in 104 medical institutions in Fujian Province
10.11816/cn.ni.2025-258044
- VernacularTitle:福建省104所医疗机构消化内镜终末漂洗用水管理现状
- Author:
Lijun QIU
1
;
Xianbin GUO
;
Yanyi GUO
;
Xuan LIN
;
Yanqing ZHANG
;
Yufang CHEN
;
Qiaomei WANG
;
Yudai CHEN
Author Information
1. 福州大学附属省立医院医院感染管理与疾病预防控制处,福建 福州 350001
- Publication Type:Journal Article
- Keywords:
Digestive endoscopy;
Terminal Rinsing water;
Purified water;
Quality control;
Current situation investigation
- From:
Chinese Journal of Nosocomiology
2025;35(20):3162-3167
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE To investigate the current status of water management for terminal rinsing of digestive en-doscope in medical institutions in Fujian Province,and to provide reference for improving regional quality control standards.METHODS An electronic questionnaire survey was conducted from Jul.2024 to Aug.2024 through convenient sampling in secondary and above hospitals of 9 prefecture-level cities in Fujian Province.The survey covered topics such as water treatment system configuration,maintenance and water quality monitoring.RESULTS A total of 108 questionnaires were distributed and 104 valid questionnaires were collected,with an effec-tive response rate of 96.30%.The survey revealed that 78.85%(82/104)of the hospitals adopted separate water supply for each department,and 82.69%used purified water for terminal rinsing.Only 19.23%installed the final filter membrane at the water outlet.In addition,66.35%of the hospitals did not specify the service life of the wa-ter supply pipeline,and the pipeline disinfection implementation rate was 60.58%,but 31.75%of them had ir-regular disinfection frequencies,with chlorine-based disinfectants(50.79%)and peracetic acid(34.92%)being the main disinfectants.The regular conductivity monitoring rate was 47.12%,and the microbial monitoring cov-erage rate reached 90.38%,with the monitoring frequency mainly being once every quarter(60.64%),but only 20.21%used R2A medium,and 12.77%adopted the membrane filtration method for inoculation.Tertiary hospi-tals were superior to secondary hospitals in terms of film membrane pore size pass rate(87.50%vs.56.86%),pipeline disinfection implementation rate(71.43%vs.50.91%)and advanced detection method application(P<0.05).CONCLUSIONS There are issues in the management of water used for terminal rinsing of digestive endo-scopes in Fujian Province,including non-standard equipment maintenance,inconsistent monitoring methods and insufficient awareness among management personnel.It is recommended to enhance management quality by optimizing the water treatment system setup,establishing standardized monitoring procedures and strengthening professional training for personnel.