Radiation dose in interventional radiodiagnosis and radiotherapy and diagnostic reference level in Beijing
10.3760/cma.j.cn112271-20240514-00174
- VernacularTitle:北京地区介入放射诊疗辐射剂量调查及诊断参考水平探讨
- Author:
Jing JING
1
;
Peng YU
;
Xi WANG
;
Dongkai SHAN
;
Xinyan WU
;
Yantao NIU
Author Information
1. 解放军总医院第六医学中心心血管病医学部,北京 100048
- Publication Type:Journal Article
- Keywords:
Radiation dose;
Digital subtraction angiography (DSA);
Diagnostic reference level (DRL);
Radiation dose optimization
- From:
Chinese Journal of Radiological Medicine and Protection
2025;45(9):898-903
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the relevant data on radiation dose in interventional radiodiagnosis and radiology of adults in Beijing and to provide a basis for establishing relevant diagnostic reference levels (DRLs) in this region.Methods:A total of 30 medical institutions in Beijing were surveyed, covering interventional radiodiagnosis and radiology surgeries for coronary artery, structural heart diseases, permanent cardiac pacemaker implantation, electrophysiological study and radiofrequency ablation, nervous systems, abdominal systems, and the blood vessels of the lower limbs. The primary parameters investigated included the air kerma area product ( PKA) and incident air kerma ( Ka, r). The 75 th percentiles of radiation dose were considered DRLs, which were analyzed at both the overall and individual medical institution levels. Results:A total of 3 331 cases of the abovementioned radiodiagnosis and radiology surgeries were collected. The DRLs (i.e., PKA and Ka, r) of various diagnostic examinations were 37.87 Gy·cm 2 and 509.00 mGy for coronary artery, 9.34 Gy·cm 2 and 48.00 mGy for electrophysiological study and radiofrequency ablation, 218.50 Gy·cm 2 and 901.70 mGy for nervous systems, 81.00 Gy·cm 2 and 302.20 mGy for the abdominal system, and 83.37 Gy·cm 2 and 214.69 mGy for the blood vessels of the lower limbs. In contrast, the DRLs (i.e., PKA and Ka, r) for interventional radiodiagnosis and radiology were determined at 135.00 Gy·cm 2 and 1 897.58 mGy for coronary artery, 26.91 Gy·cm 2 and 172.30 mGy for structural heart diseases, 27.77 Gy·cm 2 and 87.75 mGy for permanent cardiac pacemaker implantation, 34.46 Gy·cm 2 and 247.00 mGy for electrophysiological study and radiofrequency ablation, 214.36 Gy·cm 2 and 1 282.80 mGy for the nervous system, 196.64 Gy·cm 2 and 875.71 mGy for abdominal system, and 108.25 Gy·cm 2 and 523.25 mGy for the blood vessels of the lower limbs. Conclusions:The DRLs of radiation dose in interventional radiodiagnosis and radiology in Beijing were determined through a survey and statistic analysis. These findings suggest that for certain interventional procedures, the optimized radiation protection should be enhanced.