Application of holographic imaging digital localization technology in robotic partial nephrectomy for completely endophytic renal tumor
10.3760/cma.j.cn112330-20250321-00112
- VernacularTitle:全息影像数字定位技术在完全内生型肾肿瘤机器人肾部分切除术中的应用
- Author:
Zhengsheng LIU
1
;
Shuaishuai SONG
1
;
Xuegang WANG
1
;
Kaiyan ZHANG
1
;
Wei LI
1
;
Zhun WU
1
;
Bin CHEN
1
;
Tao WANG
1
;
Jinchun XING
1
Author Information
1. 厦门大学附属第一医院泌尿外科,厦门 361003
- Publication Type:Journal Article
- Keywords:
Kidney neoplasms;
Completely endophytic;
Holographic imaging;
Robot-assisted partial nephrectomy
- From:
Chinese Journal of Urology
2025;46(5):376-382
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the clinical value of holographic imaging-based digital localization technology in robot-assisted partial nephrectomy(RAPN)for the treatment of completely endophytic renal tumors.Methods:A retrospective analysis was conducted on the clinical data of 23 patients with completely endophytic renal tumors who underwent RAPN at the First Affiliated Hospital of Xiamen University between December 2022 and December 2024. Patients were divided into two groups based on the use of holographic imaging:the holographic imaging group(16 cases)and the conventional group(7 cases). There was no statistically significant difference between the holographic imaging group and the conventional group in terms of age[(41.9 ± 13.4)years vs.(46.9 ± 13.4)years],body mass index[(25.6 ± 4.8)kg/m2 vs.(24.7 ± 3.1)kg/m2],maximum tumor diameter[(3.1 ± 0.9)cm vs.(3.0 ± 9.0)cm],tumor volume[(13.2 ± 9.0)cm3 vs.(34.9 ± 9.9)cm3],R.E.N.A.L. score[(9.4 ± 1.2)points vs.(9.9 ± 0.7)points],PADUA score[(10.4 ± 0.7)points vs.(9.4 ± 0.7)points],proportion of T 1a stage patients[12 cases(75.0%)vs. 6 cases(85.7%)]and preoperative serum creatinine[(67.4 ± 9.5)μmol/L vs.(78.0 ± 16.0)μmol/L]. In the holographic group,holographic models were reconstructed based on preoperative enhanced CT or MRI images and used for preoperative planning and intraoperative localization. In the conventional group,surgeons relied on preoperative CT or MRI images for cognitive fusion during RAPN. Perioperative parameters such as warm ischemia time,operative time,tumor localization time,positive surgical margin rate,and renal function were compared between the two groups. Results:The operative time in the holographic group was significantly shorter than that in the conventional group[(152.8 ± 12.9)min vs.(218.4 ± 105.5)min, P = 0.001]. Warm ischemia time[(26.9 ± 3.4)min vs.(30.7 ± 3.8)min, P < 0.001],localization time[(4.2 ± 0.9)min vs.(8.9 ± 1.7)min, P < 0.001],and estimated blood loss[(47.0 ± 17.7)ml vs.(128.6 ± 87.8)ml, P < 0.001]were also significantly lower in the holographic group. In the conventional group,one patient underwent radical nephrectomy,while no patient in the holographic imaging group required conversion to radical nephrectomy. No cases of positive surgical margins were identified in either group. Serum creatinine levels measured one month after surgery showed no statistically significant differences between the two groups[(79.5 ± 15.7)μmol /L vs.(104.9 ± 22.5)μmol /L]. Conclusions:The application of holographic imaging-based digital localization technology in RAPN for completely endophytic renal tumors significantly reduces operative time,localization time,warm ischemia time,and intraoperative blood loss. This technology improves surgical efficiency and success rates,offering distinct clinical advantages.