Influence of quality sensitive indicator optimization process management combined with information traceability system on management quality for external medical apparatuses in central sterile supply department
10.3969/j.issn.1672-8270.2025.09.023
- VernacularTitle:质量敏感指标优化流程管理联合信息追溯系统对消毒供应中心外来医疗器械管理质量的影响
- Author:
Jing GAO
1
;
Yuanyuan XU
1
;
Yue XIA
1
;
Xiujuan LIANG
1
Author Information
1. 首都医科大学附属北京友谊医院消毒供应中心 北京 101100
- Publication Type:Journal Article
- Keywords:
Quality sensitive indicator;
Optimization process;
Information traceability system;
Central sterile supply department(CSSD);
Management quality
- From:
China Medical Equipment
2025;22(9):114-120
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the influence of quality sensitive indicator optimization process management combined with information traceability system on management quality for external medical apparatuses in central sterile supply department(CSSD),so as to realize comprehensive,accurate and efficient management for external medical apparatuses.Methods:The quality sensitive indicators of management for external medical apparatuses were determined,and information traceability system was applied to record the information of apparatuses,and the management measures were optimized from retrieving,cleaning,packaging,sterilization and distribution one by one to manage apparatuses.A total of 400 external apparatuses that were cleaned and sterilized at CSSD of Beijing Friendship Hospital,Capital Medical University from January 2022 to January 2024 were selected.The 200 external medical apparatuses from January 2022 to January 2023 were managed by conventional management mode,and other 200 external medical apparatuses from February 2023 to January 2024 were managed by quality sensitive indicator optimization process management combined with information traceability system(combined management mode).The two management modes were compared in terms of management quality scores,management effects,incidence rates of adverse events and incidence rates of nosocomial infection for external medical apparatuses,as well as the theoretical and operational achievement results of CSSD staffs in each link.Results:The management quality scores of combined management mode for external medical apparatuses in the links of cleaning,sterilization,packaging,storage and distribution were respectively(18.05±1.05)points,(18.23±0.62)points,(17.13±1.01)points,(16.30±1.15)points and(17.08±1.02)points,which were higher than those of conventional management mode(t=11.454,3.738,5.517,4.094,7.375,P<0.05).The qualified rates of cleaning,disassembly,assembly,and the time of delivering apparatuses were higher than those of conventional management mode,while the error rate of packaging was lower than that of conventional management mode(x2=11.308,21.711,23.236,18.254,8.688,P<0.05).Both of theoretical and operational achievement results of CSSD staffs were higher than those of conventional management mode,and the differences were significant(t=4.132,4.363,P<0.05).The total incidence rate of adverse events and incidence rate of nosocomial infection were lower than those of conventional management mode,and the differences were significant(x2=13.474,4.230,P<0.05).Conclusion:The quality sensitive indicator optimization process management combined with information traceability system can significantly improve the management quality and management efficiency of CSSD for external medical apparatuses,and reduce the risk of occurring adverse events,and enhance business knowledge level and operational skills of CSSD staff.