Subchondral bone intravoxel incoherent motion diffusion weighted imaging for quantitatively evaluating knee joint cartilage degeneration
10.13929/j.issn.1003-3289.2025.07.020
- VernacularTitle:软骨下骨体素内不相干运动弥散加权成像定量评估膝关节软骨退行性变
- Author:
Kai GAO
1
;
Jiming CHEN
1
;
Xianfei WEI
1
;
Yongkang SONG
1
;
Jian ZHAI
1
Author Information
1. 皖南医学院第一附属医院影像中心,安徽芜湖 241001
- Publication Type:Journal Article
- Keywords:
knee joint;
subchondral bone;
magnetic resonance imaging;
intravoxel incoherent motion;
prospective studies
- From:
Chinese Journal of Medical Imaging Technology
2025;41(7):1129-1133
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the value of subchondral bone(SB)intravoxel incoherent motion diffusion weighted imaging(IVIM-DWI)for quantitatively evaluating knee joint cartilage degeneration.Methods Totally 125 patients with knee cartilage degeneration were prospectively enrolled and divided into mild group(n=65,Outerbridge grades Ⅰ-Ⅱ)and moderate-severe group(n=60,Outerbridge grades Ⅲ-Ⅳ)based on arthroscopic findings.Additionally,30 healthy young subjects were recruited as control group.The apparent diffusion coefficient(ADC),true diffusion coefficient(D),pseudo diffusion coefficient(D*)and perfusion fraction(f)values of medial condyle of SB of femur,lateral condyle of femur,medial tibial plateau and lateral tibial plateau,as well as the mean values of each parameter of the above 4 regions were obtained based on knee joint IVIM-DWI and compared within and among groups.Spearman correlation analysis was used to observe the correlations between quantitative parameters and Outerbridge grading.The area under the receiver operating characteristic curve(AUC)was calculated to evaluate the efficacy of each quantitative parameter alone and their combination for assessing knee cartilage degeneration.Results Significant differences of D*values were found among different parts of knee joint SB in moderate-severe group,also of D value,D* value and f value among different parts of knee joint SB in mild group(all P<0.05).Significant differences of IVIM-DWI parameter were found among different parts of knee joint SB in control group(all P<0.05).ADC value of knee joint SB in moderate-severe group,mild group and control group decreased successively,while D value increased successively(all P<0.001).D* values of knee joint SB in moderate-severe group was higher than that in mild group and control group(both P<0.05).No significant difference of f value of knee joint SB was found between moderate-severe group and mild group(P>0.05),while both the latter two were higher than that in control group(both P<0.05).ADC value,D value and f value of knee joint SB were positively correlated(rs=0.671,0.634,0.416,all P<0.01),while D* value of knee joint SB was negatively correlated with Outerbridge grading(rs=-0.729,P<0.01).AUC of combination of parameters for distinguishing mild group from control group,and mild group from moderate-severe group was 0.859 and 0.808,respectively.Conclusion SB IVIM-DWI could be used for quantitatively evaluation of knee cartilage degeneration.