Safety and efficacy of the reamer-irrigator-aspirator technique in adult lower extremity long bone nonunion
10.3760/cma.j.cn121113-20250604-00520
- VernacularTitle:扩髓-灌注-吸引技术取骨用于下肢长骨非感染性骨不连翻修的疗效及安全性
- Author:
Hui DONG
1
;
Wenxiang LI
1
;
Liangyu ZHU
1
;
Wei YUAN
1
;
Aiguo WANG
1
;
Xinghua LI
1
Author Information
1. 郑州市骨科医院下肢骨科一病区,郑州 450052
- Publication Type:Journal Article
- Keywords:
Femur;
Tibia;
Fractures, ununited;
Bone transplantation;
Ilium;
Reamer-irrigator-aspirator
- From:
Chinese Journal of Orthopaedics
2025;45(20):1327-1334
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the clinical efficacy of the reamer-irrigator-aspirator (RIA) technique and iliac crest bone grafting (ICBG) in the treatment of adult noninfectious long bone nonunion of the lower extremity, and to evaluate the safety and effectiveness of the RIA technique.Methods:A retrospective review was conducted of 42 adult patients with noninfectious long bone nonunion of the lower extremity treated surgically at Zhengzhou Orthopaedic Hospital from January 2021 to June 2024. The cohort included 33 men and 9 women with a mean age of 47.0±14.4 years (range, 18-62 years). Twenty-three patients had nonunion on the left side and 19 on the right. Initial surgical fixation methods included plate fixation (19 cases), intramedullary nail (16 cases), external fixator (5 cases), and combined plate-and-nail fixation (2 cases). Revision procedures included debridement and freshening of the nonunion ends, revision or adjustment of internal fixation, and autologous bone grafting. Nineteen patients underwent graft harvesting with the RIA technique (RIA group), and 23 received autograft harvested from the iliac crest (iliac group). Baseline and perioperative variables compared between the two groups included sex, age, body-mass index, preoperative comorbidities, anatomical site of the nonunion (tibial or femoral), duration from the index fracture operation to the current revision, operative time, intraoperative blood loss, volume of blood transfusion and rate of perioperative complications, nonunion fracture sites, visual analogue scale (VAS) pain score at the fracture site, donor-site morphology and functional appearance scores, and radiographic union score for tibial fractures (RUST).Results:There was no significant difference in age between the RIA and ICBG groups (45.1±14.1 vs. 48.5±14.7 years, t=0.746, P=0.449). However, intraoperative blood loss was higher in the RIA group [300 (150, 720) ml, Z=-3.072, P=0.002] and the transfusion rate was higher (14/19 vs. 8/23, χ 2=6.313, P=0.012). The harvested bone volume was very similar [40(35, 60) cm 2vs. 40(35, 40) cm 2, Z=-1.077, P=0.281]. All patients were followed for a mean of 16.5±2.8 months (range, 7-40 months). VAS scores at the surgical site showed no significant difference between groups at 3 months (3.2±1.0 vs. 3.3±1.4, t= 4.754, P=0.720) and 6 months (1.6±0.8 vs. 1.8±1.2, t=6.841, P=0.542). Donor-site morphology and functional scores were significantly better in the RIA group at 3 months [14.5(13.0, 15.5) vs. 9.0(7.0, 10.0), Z=-3.748, P<0.001] and 6 months [15.5(15.0, 16.0) vs. 11.0(10.0, 13.0), Z=-3.782, P<0.001]. At 12 months postoperatively, RUST scores did not differ significantly between groups (10.6±1.2 vs. 10.4±1.5, t=0.483, P=0.632). The incidence of perioperative complications was comparable [42%(8/19) vs. 30%(7/23), χ 2=0.617, P=0.432]. Conclusions:Both RIA and ICBG achieved favorable clinical outcomes in the treatment of adult noninfectious lower-extremity long bone nonunion. Although RIA was associated with greater intraoperative blood loss, it resulted in less donor-site morbidity and better cosmetic and functional outcomes. Bone healing capacity and overall complication rates did not differ significantly between the two groups. These findings suggest that the RIA technique is safe and effective for use in the Chinese patient population.