Abstract:
Objective:To analyze the selection of internal fixation methods, surgical outcomes, and complications in patients with Neurofibromatosis Type 1 (NF1) accompanied by dystrophic lumbosacral deformities, and to evaluate the indications for pelvic fixation.Methods:A retrospective analysis was conducted on 21 patients with NF1 and associated dystrophic lumbosacral malformations (L 4 to sacrum) who underwent spinal deformity correction surgery at Nanjing Drum Tower Hospital from January 2009 to November 2022. The cohort included 11 males and 10 females, with a mean surgical age of 15.4±4.7 years (range, 7-24 years). Patients were divided into two groups based on whether pelvic fixation was performed: 10 patients in the non-pelvic fixation group (NP group) and 11 in the pelvic fixation group (P group), where fixation involved second sacral alar-iliac (S 2AI) screws or iliac screws. Radiographic parameters, including the Cobb angle of the lumbosacral fractional curve, main curve, and focal kyphosis, were compared preoperatively, postoperatively, and at the last follow-up. Results:The NP group had a significantly lower mean age (13.2±4.9 years) compared to the P group (17.5±3.5 years; t=2.287, P=0.034). Spinal instability (rotational subluxation or spondylolisthesis) due to dystrophic changes was observed in 2 patients in the NP group and 8 in the P group, a statistically significant difference (χ 2=5.838, P=0.030). In the P group, five patients underwent unilateral fixation and six underwent bilateral fixation. Implant types included 2 cases with iliac screws, 1 case with iliac screws plus S 2AI, and 8 cases with S 2AI screws alone. The utilization rate of hooks was significantly higher in the NP group (12.6%±11.5%) compared to the P group (3.5%±6.9%; t=2.230, P=0.038). The preoperative Cobb angle of the lumbosacral fractional curve was significantly smaller in the NP group (13.8°±9.0°) than in the P group (25.5°±13.9°; t=2.228, P=0.039). Postoperatively, the angles were corrected to 6.3°±6.1° and 6.4°±5.3°, respectively ( t=0.901, P=0.969), with correction rates of 57.3%±13.6% and 74.1%±17.8% ( t=2.369, P=0.029). At final follow-up, the angles remained stable (6.6°±6.6° vs. 6.3°±4.8°; t=0.116, P=0.909). For the main curve, preoperative Cobb angles were 52.5°±15.1° (NP) and 61.1°±16.9° (P; t=1.200, P=0.246), corrected to 31.3°±13.8° and 28.0°±8.4°, respectively ( t=0.646, P=0.526). Correction rates were 41.3%±13.0% in the NP group and 53.2%±11.6% in the P group ( t=2.206, P=0.037). At the final follow-up, these values were 32.4°±14.2° and 31.7°±10.3° ( t=0.133, P=0.896). Focal kyphosis, seen in 9 patients, was corrected from 19.7°±10.9° preoperatively to -13.6°±9.5° postoperatively, and remained at -14.1°±9.6° at the final follow-up ( F=33.547, P<0.001). Multi-rod systems were used in 6 cases (NP group) and 7 cases (P group), with no significant difference (χ 2=0.153, P=0.926). Two patients in the NP group developed coronal decompensation three years postoperatively, and one required revision surgery. In the P group, rod breakage occurred in 3 patients, two of whom underwent revision. Conclusions:Dystrophic rotational subluxation or spondylolisthesis of the lumbosacral spine is a primary indication for pelvic fixation in patients with NF1-associated deformities. However, complications related to internal fixation remain common. The combined use of a multi-rod screw-hook hybrid system, particularly when extending across the lumbosacral region, may reduce the risk of instrumentation failure.