Three-dimensional CT study on the position and length of anchor placement during anterior talofibular ligament repair in adolescents with unclosed epiphyseal plates
10.3760/cma.j.cn121113-20240913-00504
- VernacularTitle:骺板未闭的青少年距腓前韧带修复术中锚钉置入位置及长度的三维CT研究
- Author:
Jie WANG
1
;
Mingliang CHEN
1
;
Chengyi GU
1
;
Zhipeng TIAN
1
;
You ZHOU
1
Author Information
1. 三峡大学附属仁和医院骨科,三峡大学运动医学研究所,宜昌市运动损伤与修复临床医学研究中心,宜昌 443001
- Publication Type:Journal Article
- Keywords:
Adolescent;
Ankle injuries;
Ligaments;
Fibula;
Growth plate;
Tomography, X-ray computed
- From:
Chinese Journal of Orthopaedics
2025;45(5):288-293
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the position and length of anchor placement during the repair of anterior talofibular ligament (ATFL) in adolescents with unclosed epiphyseal plates by measuring the relevant data in three-dimensional CT.Methods:A total of 100 three-dimensional CT images of adolescent patients with unclosed epiphyseal plates were collected from the database of the Radiology Center of Renhe Hospital Affiliated to China Three Gorges University from January 1, 2017 to January 1, 2024. There were 69 males and 31 females, aged 12.38±0.90 years (range, 11-14 years), 47 on the left side and 53 on the right side, with a height of 155.72±5.84 cm (range, 145-175 cm), a weight of 48.02±5.93 kg (range, 40-72 kg), and a body mass index (BMI) of 19.77±1.61 kg/m 2 (range, 17.69-24.91 kg/m 2). The built-in measurement tool of the picture archiving and communication system (PACS) was used to measure the angle (α) between the direction of the nail placement and the longitudinal axis of the fibula, the distance between the nail placement point and the posterior edge of the fibula ( d), and the height from the nail placement point to the level of the fibula tip ( h) to evaluate the position and length of the anchor placement. Results:In adolescent patients, α was 47.50°±3.28° (range, 40.00°-56.00°), d was 17.12±1.80 mm (range, 11.70-21.90 mm), and h was 5.21±1.17 mm (range, 3.40-7.90 mm). The α, d and h of male patients were 47.48°±3.13° (range, 42.00°-56.00°), 17.49±1.54 mm (range, 14.45-21.90 mm) and 5.25±1.07 mm (range, 3.70-7.90 mm), respectively. Those of female patients were 47.55°±3.66° (range, 40.00°-53.00°), 16.30±2.07 mm (range, 11.65-20.30 mm) and 5.07±1.56 mm (range, 3.40-7.00 mm), respectively. There was a significant difference in d between male and female patients ( t=3.193, P=0.002), but there was no significant difference in α and h ( t=0.098, P=0.922; t=0.296, P=0.770). Conclusions:The safe range of anchor placement during ATFL anatomical repair in adolescents with unclosed epiphyseal plates is about 3.40-7.90 mm above the tip of fibula and 56°-90° with the longitudinal axis of fibula. Male patients with unclosed epiphyseal plates should choose anchors with a length of 14 mm and shorter, while females should choose anchors with a length of 10.8 mm.