Reliability and validity of the repeatable battery for assessment of neuropsychological status scale in maintenance hemodialysis patients
10.3969/j.issn.1006-7795.2025.05.017
- VernacularTitle:可重复的成套心理状态测量表在维持性血液透析患者中的信效度分析
- Author:
Xiaoqi WANG
1
;
Conghui LIU
1
;
Feng SHAO
1
;
Jingjing ZHOU
1
;
Fan YANG
1
;
Zhongxin LI
1
Author Information
1. 首都医科大学附属北京潞河医院肾病中心,北京 101149
- Publication Type:Journal Article
- Keywords:
neuropsychological assessment;
cognitive impairment;
maintenance hemodialysis;
reliability;
validity;
Repeatable Battery for the Assessment of Neuropsychological Status
- From:
Journal of Capital Medical University
2025;46(5):877-884
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the reliability and validity of the Chinese version of the Repeatable Battery for the Assessment of Neuropsychological Status(RBANS)in patients with maintenance hemodialysis(MHD).Methods The general information and medical history of 84 MHD patients were collected,and the Mini-Mental State Exam(MMSE),Montreal Cognitive Assessment Scale(MoCA),and RBANS were conducted.The reliability of the scale was assessed by Cronbach α and split-half reliability.The structure and convergent validity of the scale were assessed by confirmatory factor analysis,and the RBANS scores'correlation to MoCA and MMSE scores was analyzed by Spearman correlation analysis.The predictive value of the RBANS total score on cognitive impairment(CI)was analyzed by receiver operating characteristic(ROC)curve.Results The Cronbach's alpha coefficient of the RBANS total scale was 0.896,split-half reliability was 0.911,and reliability for the five dimensions of the RBANS ranged from 0.618 to 0.791.Confirmatory factor analysis indicated that the overall fit of the five-dimensional model of the RBANS scale was acceptable(χ2/df=1.587,root mean square error of approximation=0.084,comparative fit index=0.967,incremental fit index=0.968,Tucker-Lewis index=0.947,goodness of fit index=0.891).The average variance extracted(AVE)for the five dimensions of the RBANS ranged from 0.525 to 0.863,while the composite reliability(CR)ranged from 0.733 to 0.926,indicating good convergent validity of the scale.Furthermore,Spearman correlation analysis revealed that the total RBANS score was negatively correlated to the age of MHD patients and positively correlated to years of education,as well as the total scores of MMSE and MoCA(all P<0.01).The ROC curve analysis indicated that the area under the curve(AUC)for the total RBANS score in predicting CI was 0.891(P<0.01),suggesting a high predictive value.Conclusion The Chinese version of RBANS has good reliability and validity in MHD patients,and can be used as a measure of cognitive function in MHD patients.