Clinical efficacy of urokinase along the pipeline under offline status to dissolve dialyzer microthrombus in patients undergoing continuous renal replacement therapy
10.3760/cma.j.cn115455-20230925-00302
- VernacularTitle:连续肾脏替代疗法患者尿激酶脱机循管溶解透析器微血栓的疗效研究
- Author:
Hua AO
1
;
Senlin QIAN
1
;
Ming LI
1
;
Aihong HE
1
;
Jun DOU
1
;
Xuebing WU
1
;
Yongqiang LIU
1
;
Qiuling ZHANG
1
Author Information
1. 三峡大学第三临床医学院 国药葛洲坝中心医院肾内科,宜昌 443002
- Publication Type:Journal Article
- Keywords:
Renal replacement therapy;
Thrombosis;
Urokinase;
Dialyzer
- From:
Chinese Journal of Postgraduates of Medicine
2025;48(1):49-54
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To observe the clinical effect of urokinase along the pipeline under offline status to dissolve dialyzer microthrombus in patients undergoing continuous renal replacement therapy (CRRT).Methods:A prospective research method was adopted. A total of 248 CRRT patients with dialyzer microthrombus in Sinopharm-Gezhouba Central Hospital from January 2017 to December 2021 were selected. The patients were divided into experimental group (continued CRRT treatment after urokinase along the pipeline under offline status to dissolve dialyzer microthrombus) and control group (continued CRRT treatment after dialyzer replacement) by random number table method with 124 cases in each group. The baseline data were recorded, including gender, age, primary disease, hemoglobin, platelet count, hematocrit, plasma albumin, D-dimer, fibrinogen, anticoagulant method and symptoms associated with dialyzer microthrombus. The blood indexes were detected before and after treatment of microthrombus, and the symptom scores were performed. The blood indexes included creatinine, urea nitrogen, β 2 microglobulin (β 2-MG), international normalized ratio (INR), hypersensitive C-reactive protein (hs-CRP), interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α); and the symptom scores included acute physiology and chronic health status score Ⅱ (APACHE Ⅱ) and (APACHE Ⅱ) and sequential organ failure score. The initial transmembrane pressure, transmembrane pressure before disembarkation, CRRT treatment extension time and coagulation classification were recorded. In experimental group, the blood coagulation function indexes before and after treatment were detected, including prothrombin time (PT), activated partial prothrombin time (APTT), thrombin time (TT) and fibrinogen (Fib). The adverse reactions were recorded, including black stools, arrhythmias and wound bleeding. Results:There were no statistical differences in baseline data, initial transmembrane pressure, transmembrane pressure before disembarkation, CRRT treatment extension time and coagulation classification between two groups ( P>0.05). There were no statistical differences in creatinine, urea nitrogen, β 2-MG, INR, hs-CRP, IL-6, TNF-α, APACHE Ⅱ and SOFA before treatment between two groups ( P>0.05); after treatment, the indexes in both groups were significantly lower than before treatment, and the indexes in experimental group were significantly lower than those in control group: (179.1 ± 41.2) μmol/L vs. (187.1 ± 53.9) μmol/L, (7.3 ± 2.8) mmol/L vs. (9.3 ± 2.5) mmol/L, (2.5 ± 0.6) mg/L vs. (4.2 ± 0.7) mg/L, 1.0 ± 0.3 vs. 1.8 ± 0.5, (8.7 ± 1.1) mg/L vs. (10.6 ± 2.4) mg/L, (21.5 ± 12.7) ng/L vs. (29.5 ± 10.3) ng/L, (20.2 ± 6.1) ng/L vs. (26.6 ± 7.2) ng/L, (12.1 ± 6.9) scores vs. (17.2 ± 5.2) scores and (5.9 ± 1.8) scores vs. (6.8 ± 1.9) scores, and there were statistical differences ( P<0.05). In experimental group, there were no statistical differences in PT, APTT, TT and Fib between before treatment and after treatment ( P>0.05). The incidence of adverse reactions in experimental group was significantly lower than that in control group: 4.03%(5/124) vs. 12.90%(16/124), and there was statistical difference ( χ2 = 6.30, P<0.05). Conclusions:The urokinase along the pipeline under offline status to dissolve dialyzer microthrombus in patients undergoing CRRT is safer, cheaper and more efficient. It can improve the biocompatibility of tissue with dialyzer and pipe, prolong the use time of the dialyzer, and complete renal replacement therapy.