Study of combining different deep learning strategies for denoising low-dose brain 18F-FDG PET images
10.3760/cma.j.cn321828-20241204-00419
- VernacularTitle:结合不同深度学习策略的低剂量脑部 18F-FDG PET图像降噪研究
- Author:
Runxiang HUANG
1
;
Fanwei ZHANG
;
Yanqi WU
;
Yu DU
;
Zhengyu PENG
;
Zhanli HU
;
Ying WANG
Author Information
1. 澳门大学科技学院电机及电脑工程系生物医学影像实验室,中国澳门 999078
- Collective Name:Mok Greta S. P.
- Publication Type:Journal Article
- Keywords:
Deep learning;
Image processing, computer-assisted;
Generative adversarial networks;
Brain;
Positron-emission tomography;
Fluorodeoxyglucose F18
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2025;45(12):744-750
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the denoising performance of different deep learning (DL) strategies on low-dose brain 18F-FDG PET images. Methods:This retrospective methodological study was conducted on brain PET/CT images of 50 patients (35 males, 15 females, age 20-87 years) who received 3.7MBq/kg 18F-FDG at the Fifth Affiliated Hospital of Sun Yat-sen University between May 2023 and January 2024. Full-dose PET data were acquired with 2min scan. CT scans were acquired before PET scanning. Low-dose PET sinograms were generated by down-sampling the full-dose list mode data to 1/2, 1/4, and 1/20 of full-dose count level. Both full-dose and low-dose sinograms were reconstructed with random, CT-based attenuation and scatter corrections using the three-dimensional (3D) ordered-subsets expectation maximization (OSEM) algorithm (2 iterations, 20 subsets). A total of 4 DL denoising methods were established: (1) 3D conditional generative adversarial networks (GAN) using only low-dose PET as input (GAN-1); (2) 3D attention-based GAN (AttGAN) with low-dose PET input (AttGAN-1); (3) 3D AttGAN with low-dose PET and CT inputs (AttGAN-2); (4) 3D AttGAN with frequency-separation using low-dose PET and CT inputs (AttGAN-FS-2). For AttGAN-FS-2, during the frequency division process, high- and low-frequency components were extracted from the PET reconstructed images via Fourier transform, then inversed Fourier transform, denoised separately, and finally combined to produce the final denoised images. The dataset was separated into training (70%), validation (10%) and testing (20%) sets using simple random sampling without replacement with a fixed random seed. A 5-fold cross-validation scheme was then applied to test all 50 patients. Performance was evaluated against full-dose PET using normalized mean square error (NMSE), structural similarity (SSIM), peak signal-to-noise ratio (PSNR), contrast-to-noise ratio (CNR), SUV mean and SUV max bias of selected brain ROIs. Wilcoxon signed rank test was used to analyze the differences between the denoising methods. Results:AttGAN-FS-2 showed the best performance among all dose levels, with statistical difference as compared by low-dose PET and GAN-1 denoised images for NMSE, SSIM, PSNR, and CNR ( Z values: 2.92-6.15, all P<0.005). NMSE, SSIM quantitative evaluation results (median) of each model at 1/20 dose were: GAN-1: 0.08, 0.87, AttGAN-1: 0.08, 0.88, AttGAN-2: 0.07, 0.89, AttGAN-FS-2: 0.06, 0.91, respectively ( Z values: 3.24-5.77, all P<0.005). Conclusion:The DL-based method combined with multiple strategies AttGAN-FS-2 shows improved denoising performance for low-dose brain PET images.