Diagnosis and radiation dosimetry of 64Cu-PSMA-Q PET/CT imaging in patients with advanced prostate cancer
10.3760/cma.j.cn321828-20241116-00403
- VernacularTitle:64Cu-PSMA-Q PET/CT显像在晚期前列腺癌患者中的诊断与辐射剂量学研究
- Author:
Fei CHEN
1
;
Hao ZHANG
;
Tielong TANG
;
Yousheng ZHAN
;
Fei LUO
;
Fanhui YANG
;
Xiaohong HUANG
;
Zongxi HE
;
Huajian GU
;
Suping LI
Author Information
1. 川北医学院附属医院核医学科,南充 637000
- Publication Type:Journal Article
- Keywords:
Prostate-specific membrane antigen;
Copper radioisotopes;
Radiation dosage;
Positron-emission tomography;
Tomography, X-ray computed
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2025;45(11):641-647
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the diagnostic performance of 64Cu-prostate specific membrane antigen (PSMA)-Q compared with 18F-FDG in patients with advanced prostate cancer and to analyze the radiation dosimetry of 64Cu-PSMA-Q. Methods:This study was an open-label, single-arm, self-controlled diagnostic evaluation trial. A total of 29 patients (age 58-87 years) with pathologically confirmed advanced prostate cancer in the Affiliated Hospital of North Sichuan Medical College from September 2023 to December 2023 were included. All patients underwent both 64Cu-PSMA-Q PET/CT and 18F-FDG PET/CT examinations. McNemar test was used to compare the detection rates of 64Cu-PSMA-Q PET/CT and 18F-FDG PET/CT for primary lesions, lymph node metastases, and bone metastases. Mann-Whitney U test was applied to compare differences in SUV max and tumor-to-background ratio (TBR) between 64Cu-PSMA-Q PET/CT and 18F-FDG PET/CT. Radiation dosimetry of 64Cu-PSMA-Q PET/CT imaging was performed using OLINDA/EXM 2.1 (adult male model) in 9 patients. Results:Primary lesions were detected in 21 patients. 64Cu-PSMA-Q PET/CT demonstrated a detection rate of 95.2%(20/21) for primary lesions, which was significantly higher than that of 18F-FDG PET/CT (66.7%(14/21); χ2=6.00, P=0.031). Detection rates of lymph node metastases were 65.5%(19/29) for 64Cu-PSMA-Q and 55.2%(16/29) for 18F-FDG, with no significant difference ( χ2=3.00, P=0.250). Similarly, detection rates of bone metastases were 72.4%(21/29) for 64Cu-PSMA-Q and 65.5%(19/29) for 18F-FDG respectively ( χ2=2.00, P=0.500). TBRs on 64Cu-PSMA-Q PET/CT were significantly higher than those on 18F-FDG PET/CT across primary lesions (8.3(2.2, 13.3) vs 2.3(1.0, 5.5); Z=7.16, P=0.002), regional lymph node metastases (4.9(1.4, 8.3) vs 1.7(0.9, 4.0), Z=189.34, P=0.001), and bone metastases (18.7(4.5, 26.9) vs 5.1(2.1, 9.7); Z=24.83, P=0.003). No significant difference in TBR was observed for distant lymph node metastases ( Z=1.49, P=0.135) or benign lesions ( Z=0.91, P=0.558). The whole-body effective dose of 64Cu-PSMA-Q was (28.200±1.590)μSv/MBq among the 9 patients analyzed, with no adverse events related to the tracer observed. Conclusion:64Cu-PSMA-Q is a promising novel PET imaging agent with potential clinical utility for diagnosing prostate cancer and supporting clinical decision-making.