Efficacy of cannulated screw internal fixation combined with quadratus femoris bone flap with preservation of the posterior superior retinaculum for femoral neck fracture in young and middle-aged patients
10.3760/cma.j.cn501098-20240910-00552
- VernacularTitle:空心螺钉内固定联合保留后上支持带股方肌骨瓣治疗青壮年股骨颈骨折的疗效
- Author:
Huan LUO
1
;
Tianhua ZHOU
1
;
Chuan LI
1
;
Luqiao PU
1
;
Xingbo CAI
1
;
Teng WANG
1
;
Chen MENG
1
;
Yaolin ZHANG
1
;
Yongqing XU
1
Author Information
1. 中国人民解放军联勤保障部队第九二〇医院骨科,昆明 650100
- Publication Type:Journal Article
- Keywords:
Femoral neck fractures;
Fracture fixation, internal;
Bone flap;
Bone screws
- From:
Chinese Journal of Trauma
2025;41(1):65-71
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the efficacy of cannulated screw internal fixation combined with quadratus femoris bone flap with preservation of the posterior superior retinaculum and cannulated screw internal fixation alone in the treatment of femoral neck fracture in young and middle-aged patients.Methods:A retrospective cohort study was conducted to analyze the clinical data of 83 young and middle-aged patients with femoral neck fracture admitted to the 920th Hospital of Joint Logistic Support Force of PLA from January 2018 to January 2023, including 56 males and 27 females, aged 28-55 years [(42.7±3.2)years]. According to Garden classification, the fractures were classified as type III in 22 patients and type IV in 61. Based on Pauwels classification, the fractures were classified as type I in 15 patients, type II in 38 and type III in 30. Forty patients were treated with cannulated screw internal fixation combined with modified quadratus femoris bone flap (cannulated screw combined with bone flap group) and 43 with cannulated screw internal fixation alone (cannulated screw group). The two groups were compared in terms of the operation time, intraoperative blood loss, time to weight-bearing, length of hospital stay, and wound healing. The visual analogue scale (VAS) scores and Harris hip function scores at 1, 3, 6, 12 months after surgery and at the last follow-up. The postoperative complication rate was detected.Results:All the patients were followed up for 20-70 months [(40.0±1.2)months]. The operation time and intraoperative blood loss were (105.2±2.7)minutes and (100.6±16.3)ml in the cannulated screw combined with bone flap group, which were longer or more than (92.4±4.7)minutes and (92.5±14.6)ml in the cannulated screw group ( P<0.01). The time to weight-bearing was (12.1±1.4)weeks in the cannulated screw combined with bone flap group, shorter than (23.6±1.2)weeks in the cannulated screw group ( P<0.01). There was no statistically significant difference in the length of hospital stay between the two groups (P>0.05). The incisions in both groups were healed by first intention. At 1 month after surgery, no statistically significant difference was observed in VAS scores between the two groups ( P>0.05); at 3, 6, 12 months after surgery and at the last follow-up, the VAS scores were (6.6±0.2)points, (4.5±0.3)points, (3.2±0.5)points, and (2.6±0.4)points in the cannulated screw combined with bone flap group, lower than (7.0±0.1)points, (5.2±0.2)points, (3.9±0.4)points, and (3.3±0.1)points in the cannulated screw group ( P<0.05 or 0.01). At 1 and 3 months after surgery, no statistically significant difference was observed in the Harris hip function scores between the two groups ( P>0.05); at 6, 12 months after surgery and at the last follow-up, the Harris hip function scores were (82.2±1.7)points, (90.0±1.4)points, and (91.6±1.0)points in the cannulated screw combined with bone flap group, higher than (75.2±1.7)points, (83.4±1.9)points, and (85.2±0.7)points in the cannulated screw group ( P<0.01). At the last follow-up, in the cannulated screw combined with bone flap group, the Harris hip function was rated excellent in 32 patients, good in 5, and fair in 3, with an excellent and good rate of 92.5%, while in the cannulated screw group, the Harris hip function was rated excellent in 20 patients, good in 13, and fair in 10, with an excellent and good rate of 76.7% ( P<0.05). The postoperative complication rate was 5.0% (2/40) in the cannulated screw combined with bone flap group, significantly lower than 23.2% (10/43) in the cannulated screw group ( P<0.05). Conclusion:Compared with cannulated screw internal fixation alone, cannulated screw internal fixation combined with quadratus femoris bone flap with preservation of the posterior superior retinaculum has the advantages of earlier weight-bearing, less pain, better recovery of hip joint function, and lower incidence of postoperative complications in the treatment of femoral neck fracture in young and middle-aged patients, despite longer operation time and more intraoperative blood loss.