Comparative efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures
10.3760/cma.j.cn501098-20250329-00173
- VernacularTitle:O形臂导航辅助与C形臂引导前路内固定治疗Anderson-D′Alonzo Ⅱ型齿状突骨折的疗效比较
- Author:
Wentao JIANG
1
;
Zhe SHAO
1
;
Kai SU
1
;
Long WANG
1
;
Peilin LIU
1
;
Liangbing GUO
1
;
Qiangqiang PAN
1
;
Qingde WANG
1
Author Information
1. 郑州市骨科医院脊柱骨科Ⅰ,郑州 450052
- Publication Type:Journal Article
- Keywords:
Cervical vertebrae;
Spinal fractures;
Fracture fixation, internal;
Navigation system
- From:
Chinese Journal of Trauma
2025;41(6):557-564
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures.Methods:A retrospective cohort study was conducted to analyze the clinical data of 58 patients with Anderson-D′Alonzo type II odontoid fractures admitted to Zhengzhou Orthopedic Hospital between January 2017 and September 2024, including 35 males and 23 females, aged 18-57 years [(39.3±9.0)years]. Anderson-D′Alonzo type II fractures were further classified as type IIA in 25 patients and type IIB in 33. Twenty-seven patients underwent O-arm assisted anterior internal fixation (O-arm navigation group), while 31 received C-arm guided anterior internal fixation (C-arm guidance group). The two groups were compared in terms of the operative duration, intraoperative blood loss, success rate for one-time guidewire placement, and intraoperative radiation exposure (anteroposterior and lateral views). At 3 days postoperatively, screw placement accuracy was evaluated via CT in both groups. Additionally, neck disability index (NDI) and visual analogue scale (VAS) scores were assessed preoperatively, at 1 week, 3 months postoperatively, and at the last follow-up. Bone union time and complication rate were also analyzed.Results:All the patients were followed up for 6-20 months [(13.1±3.4)months]. The O-arm navigation group exhibited significantly shorter operative duration [(91.1± 8.9)minutes] and less intraoperative blood loss [(38.9±8.2)ml], compared with (103.3±14.5)minutes and (47.3±9.1)ml in the C-arm guidance group ( P<0.01). The success rate for one-time guidewire placement was 100% (27/27) in the O-arm navigation group, significantly higher than 52% (16/31) in the C-arm guidance group ( P<0.01). Intraoperative radiation exposure for patients in the O-arm navigation group was lower in both anteroposterior view [(11 612.6±1 603.6)μSv] and lateral views [(29 738.2±6 602.5)μSv], compared with (40 638.0±9 431.9)μSv and (47 152.0±11 759.3)μSv in the C-arm guidance group ( P<0.01). CT scans at 3 days postoperatively revealed a 100% (27/27) screw placement accuracy in the O-arm navigation group, compared with 65% (20/31) in the C-arm guidance group ( P<0.01). Before operation, at 1 weeks and 3 months postoperatively, and at the last follow-up, NDI scores were (48.4±7.8)%, (21.0±3.1)%, (14.4±2.4)%, and (13.9±2.3)% in the O-arm navigation group, while they were (47.4±7.6)%, (20.9±3.2)%, (14.1±2.0)%, and (13.8±1.4)% in the C-arm guidance group ( P>0.05); VAS scores were 6.0(6.0, 7.0)points, 4.0(3.0, 4.0)points, 2.0(1.0, 2.0)points, and 2.0(1.0, 2.0)points in the O-arm navigation group, while they were 7.0(6.0, 7.0)points, 4.0(3.0, 5.0)points, 2.0(1.0, 3.0)points, and 2.0(2.0, 2.0)points in the C-arm guidance group ( P>0.05). The NDI and VAS scores in both groups were significantly improved at 1 weeks and 3 months postoperatively, and at the last follow-up compared to those preoperatively ( P<0.05), and were furtherly improved at 3 months postoperatively and at the last follow-up compared to those at 1 weeks postoperatively ( P<0.05), with no significant differences between those at 3 months postoperatively and at the last follow-up ( P>0.05). No significant difference was found in bone union time between the two groups ( P>0.05). The complication rate in the O-arm navigation group was 4% (1/27), lower than 29% (9/31) in the C-arm guidance group ( P<0.05). Conclusions:Compared with C-arm guidance, O-arm assisted anterior internal fixation for Anderson-D′Alonzo type II odontoid fractures can reduce operative duration and intraoperative blood loss, improve the success rate for one-time guidewire placement and screw accuracy, and decrease radiation exposure and complication rate.