Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
10.3760/cma.j.cn112149-20250101-00001
- VernacularTitle:测量位置对冠状动脉CT血流储备分数诊断效能的影响
- Author:
Yutao ZHOU
1
;
Na ZHAO
;
Yunqiang AN
;
Lei SONG
;
Chaowei MU
;
Jingang CUI
;
Tao JIANG
;
Li XU
;
Hongjie HU
;
Lin LI
;
Dumin LI
;
Wenqiang CHEN
;
Lijuan FAN
;
Feng ZHANG
;
Yang GAO
;
Bin LYU
Author Information
1. 中国医学科学院 北京协和医学院 国家心血管病中心 阜外医院放射影像科,北京 100037
- Publication Type:Journal Article
- Keywords:
Coronary artery disease;
Myocardial ischemia;
Fractional flow reserve, myocardial;
Coronary computed tomography angiography;
Computational fluid dynamics
- From:
Chinese Journal of Radiology
2025;59(6):704-711
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.