Endovascular Treatment for Pseudoaneurysm at the Distal Anastomosis after the Surgical Repair of Aortic Coarctation
- VernacularTitle:大動脈縮窄症術後の遠位吻合部仮性動脈瘤に対するステントグラフト内挿術の1例
- Author:
Naoki TATEISHI
1
;
Ryo IMADA
1
;
Fumiya ONO
1
;
Yushi YAMASHITA
1
;
Koji TAO
1
;
Tamahiro KINJO
1
Author Information
- Keywords: coarctation of aorta; pseudoaneurysm; TEVAR
- From:Japanese Journal of Cardiovascular Surgery 2025;54(3):127-129
- CountryJapan
- Language:Japanese
- Abstract: A 70-year-old woman with a history of bypass surgery for coarctation of the aorta (CoA) at approximately 10 years of age was referred to our hospital after a descending thoracic aortic aneurysm was discovered during a preoperative examination for uterine cancer. Contrast-enhanced CT revealed a 62×47 mm aneurysm in the descending thoracic aorta, connected to the bypass vessel, leading to the diagnosis of an anastomotic pseudoaneurysm following CoA surgery. Due to the large diameter of the aortic aneurysm and the high risk of rupture, we performed a left axillary artery to left femoral artery bypass in addition to thoracic endovascular aortic repair (TEVAR). Postoperative CT indicated no endoleak, and the patient was discharged after uterine cancer surgery with an uneventful recovery.