Application of ultrasound multimodal diagnostic mode combined with ultrasonic precision interventional technology in differentiating the benign from malignant solid breast masses
10.3969/j.issn.1008-794X.2025.01.011
- VernacularTitle:超声多模态诊断模式联合超声精准介入技术在乳腺实性肿物良恶性性质鉴别中的应用
- Author:
Shipeng WANG
1
;
Weihong NIE
;
Junde LIU
;
Yunfeng CHEN
;
Caixia GUO
;
Xiang LI
;
Yihe ZHANG
Author Information
1. 733000 甘肃武威 武威肿瘤医院超声医学科
- Keywords:
breast mass;
diagnosis;
multimodal ultrasound;
contrast-enhanced ultrasound;
intervention
- From:
Journal of Interventional Radiology
2025;34(1):70-74
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the application of ultrasound multimodal diagnostic mode combined with ultrasonic precision interventional technology in differentiating the benign from malignant solid breast masses.Methods A total of 396 patients who underwent breast surgery at the Wuwei Cancer Hospital of China from May 2021 to July 2023 were enrolled in this study.Within 2 weeks before surgery,multimodal ultrasound examination(including two-dimensional ultrasound,color Doppler ultrasound,elastic ultrasound,breast three-dimensional ultrasound,and contrast-enhanced ultrasound)and ultrasound-guided needle biopsy were performed in all patients.The consistency between the results of multimodal ultrasound examination,ultrasound-guided needle biopsy,combination diagnosis and the postoperative pathological diagnoses was analyzed.Results Of the 396 patients with solid breast mass,malignant lesion was seen in 237(59.85%)and benign lesion was seen in 159(40.15%).The sensitivity of multimodal ultrasound in diagnosing benign and malignant solid breast masses was 77.64%(184/237),the specificity was 90.57%(144/159),the positive predictive value was 92.46%(184/199),the negative predictive value was 73.10%(144/197),the accuracy was 82.83%(328/396),and the consistency with the postoperative pathological diagnosis was 0.656.The sensitivity of ultrasound-guided needle puncture in diagnosing benign and malignant solid breast masses was 94.51%(224/237),the specificity was 100.00%(159/159),the positive predictive value was 100.00%(224/224),the negative predictive value was 92.44%(159/172),the accuracy was 96.72%(383/396),and the consistency with the postoperative pathological diagnosis was 0.933.The sensitivity of multimodal ultrasound combined with ultrasound-guided needle puncture in diagnosing benign and malignant solid breast masses was 100.00%(228/228),the specificity was 94.64%(159/168),the positive predictive value was 96.20%(228/237),the negative predictive value was 100.00%(159/159),the accuracy was 97.73%(387/396),and the consistency with the postoperative pathological diagnosis was 0.937.Conclusion The ultrasound multimodal diagnostic mode and ultrasonic precision interventional technology can be used in differentiating the benign from malignant solid breast masses with high diagnostic accuracy.