Development and verification of an ELISA method for antigen detection of recombinant rotavirus VP8 proteins
10.13200/j.cnki.cjb.004637
- VernacularTitle:冀颖,孙艳艳,纪国存,龙静,苏桂民,杜琳
- Author:
Ying JI
1
Author Information
1. Beijing Bacterial Vaccine Engineering Research Center, Vaccine Research and Development Center, Beijing Zhifei Lvzhu Biopharmaceutical Co., Ltd., Beijing 100176, China
- Publication Type:Journal Article
- Keywords:
Rotavirus(RV);
Monoclonal antibody(McAb);
Rabbit-derived polyclonal antibody;
Double-antibody sandwich ELISA
- From:
Chinese Journal of Biologicals
2026;39(01):67-77
- CountryChina
- Language:Chinese
-
Abstract:
Objective To prepare specific antibodies against VP8 proteins of rotavirus(RV) genotypes P[8], P[6], and P[4], and to initially establish and verify an ELISA method for the detection of recombinant RV VP8 protein antigens.Methods Female BALB/c mice were immunized with recombinant P[8], P[6], and P[4]type VP8 proteins at a dose of60 μg per mouse with three mice for each type, and booster immunizations were administered via intramuscular injection in the leg at the same dose for 4 times at intervals of 2 to 4 days. Splenocytes from the immunized mice were fused with SP2/0 cells to screen for monoclonal antibodies(McAbs) against P[8], P[6], and P[4]type VP8 proteins. Polyclonal antibodies were obtained by immunizing rabbits. A double-antibody sandwich ELISA method for detecting recombinant RV VP8 protein antigens was initially established by optimizing the pairing combinations of capture and detection antibodies as well as their working concentration. The linearity and range of the standard curve were determined, and the precision, accuracy, and specificity of the method were verified. The established method was applied to detect intermediate samples(bacterial cell lysate, crude extract, purified solutionⅠ, and purified solutionⅡ) from the preparation and purification processes of three batches of P[8], P[6], and P[4]type VP8 proteins.Results One hybridoma cell line secreting anti-P[8]McAb was screened and named P[8]-19E7; two anti-P[6]McAb-secreting cell lines were obtained, designated as P[6]-4B8 and P[6]-8F11; and one anti-P[4]McAb-secreting cell line was identified, named P[4]-11E3. Additionally, rabbit polyclonal antibodies against P[8], P[6]and P[4]were prepared. For the P[6]antigen detection, both the capture antibody(30 μg/mL)and the detection antibody(1. 0 μg/mL) were mouse McAbs, with a standard curve range of 10. 00 to 640. 00 ng/mL. For the P[8]and P[4]antigen detection, the capture antibodies were McAbs, with the concentration of 5 μg/mL and 2. 5 μg/mL respectively, the detection antibodies were rabbit polyclonal antibodies, both at the concentration of 1. 5 μg/mL, and their standard curve ranges were 0. 63-20. 00 ng/mL and 0. 31-10. 00 ng/mL respectively. The coefficients of variation(CVs) of the six test results for the antigen content of P[8], P[6]and P[4]proteins were all less than 10%, the recovery rates ranged from 80% to 120%, and the specificity was good. The CVs of antigen recovery yield for the in-process products from three batches of purification processes were all less than 30%.Conclusion The screened monoclonal cell lines secrete antibodies that specifically target the P[8], P[6]and P[4]subtypes of VP8 protein without cross-reactivity, and exhibit high antibody titers. The recombinant RV VP8 protein antigen detection method established based on these antibodies demonstrates strong specificity, high sensitivity, and excellent precision.