Correlation between electronic cross-matching and the detection rate of unexpected antibodies in red blood cells
10.13303/j.cjbt.issn.1004-549x.2025.10.011
- VernacularTitle:电子交叉配血与红细胞意外抗体检出率的相关性分析研究
- Author:
Can LOU
1
;
Hang LEI
2
;
Yuqing WANG
2
;
Songsong GONG
2
;
Xuefeng WANG
3
;
Wei ZOU
2
;
Xiaohong CAI
1
;
Shikai CHEN
4
Author Information
1. Laboratory Diagnostic Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Blood Transfusion, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Laboratory Medicine, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025China
2. Laboratory Diagnostic Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Blood Transfusion, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
3. Laboratory Diagnostic Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Blood Transfusion, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Laboratory Medicine, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025China; Department of Laboratory Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
4. Laboratory Diagnostic Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China; Department of Laboratory Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
- Publication Type:Journal Article
- Keywords:
electronic cross-matching;
Rh antibody;
antibody screening;
clinical blood transfusion;
statistical analysis
- From:
Chinese Journal of Blood Transfusion
2025;38(10):1370-1376
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To analyze changes in Rh system antibodies among antibody-positive patients and evaluate the efficacy of Rh phenotype-matched electronic cross-matching (hereinafter referred to as Rh-ECM). Methods: A retrospective analysis was performed on antibody screening data of 48 254 patients in our hospital from December 2023 to March 2025. The antibody screening results were compared between the pre-application phase (n=46 346, control group) and post-application phase (n=48 254, experimental group) of Rh-ECM technology, focusing on the changes in the proportion of Rh system antibodies, with statistical analysis conducted using SPSS 26.0 software. Meanwhile, the initial and re-examination situations of Rh antibody in the antibody screening of approximately 20 000 person-times each before (June 2019 to June 2020, n=21 048) and after (July 2020 to April 2021, n=20 965) of Rh-ECM were evaluated to explore the influence of Rh-ECM on the detection rate of Rh antibody. Results: After Rh-ECM implementation, 345 positive cases (0.7%) (345/48 254) were detected among 48 254 patients, primarily consisting of mns system antibodies (128 cases, 37.1%) (128/345) and rh system antibodies (95 cases, 27.5%) (95/345). Before Rh-ECM implementation, 199 positive cases (0.4%) (199/46 346) were detected among 46 346 patients, with rh system antibodies accounting for 97 cases (48.7%) (97/199). The difference in the composition ratio of Rh antibodies between the two phases was statistically significant (P<0.001), and the relative risk ratio of Rh antibody detection after Rh-ECM implementation was 56.5% compared to before. Another set of data analysis showed that before Rh-ECM, there were 37 cases with initial positive results and 8 cases with re-examination positive results; after Rh-ECM, these numbers were 44 and 2 respectively There was a statistically significant difference in the re-examination positive rate of Rh antibodies between the two stages (P<0.05). Conclusion: The implementation of Rh-ECM technology significantly reduced the proportion of Rh system antibodies among patients with positive antibody screening results. This suggests that Rh-ECM can effectively reduce the detection rate of Rh antibodies, which may be related to the reduced risk of antibody production due to Rh-matched transfusion, thus improving transfusion safety. Therefore, Rh-ECM is worthy of broader promotion in clinical transfusion testing.