Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
10.12200/j.issn.1003-0034.20250514
- Author:
Xiang ZHAO
1
;
Xiang-Hua WANG
1
;
Rong-Xin HE
1
;
Xun-Zi CAI
1
;
Li-Dong WU
1
;
Hao-Bo WU
1
;
Shi-Gui YAN
1
Author Information
1. The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang, China.
- Publication Type:English Abstract
- Keywords:
Enhanced workflows;
Express workflows;
Robotic-assisted;
Total hip arthroplasty
- MeSH:
Humans;
Arthroplasty, Replacement, Hip/methods*;
Male;
Female;
Aged;
Middle Aged;
Robotic Surgical Procedures/methods*;
Retrospective Studies;
Aged, 80 and over;
Workflow;
Treatment Outcome
- From:
China Journal of Orthopaedics and Traumatology
2025;38(10):987-993
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION:The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.