Comparative study on non inferiority of MRI knee joint 8 channel hard coil and 16 channel flexible coil
10.3969/j.issn.1002-1671.2024.06.031
- VernacularTitle:MRI膝关节8通道硬质线圈与16通道柔性线圈的使用非劣效性对比研究
- Author:
Lei ZHENG
1
;
Tingting ZHOU
;
Hao YUAN
;
Li CHEN
;
Hongyan WU
;
Nan ZHU
Author Information
1. 蚌埠市中医医院影像科,安徽 蚌埠 233000
- Keywords:
knee joint;
magnetic resonance imaging;
hard coil;
flexible coil;
image quality
- From:
Journal of Practical Radiology
2024;40(6):994-997
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the imaging quality and use convenience between hard and flexible coils,and to analyze the applicability of the two coils in clinical work.Methods Patients who underwent MRI examination of the knee joint were divided into 2 groups,group A using a hard coil and group B using a flexible coil.Differences in image signal-to-noise ratio(SNR),subjective scores,exami-nation times,and uniformity were compared between the two groups.Independent samples t-test was used and P<0.05 was consid-ered significant.Results There were no significant statistical differences in image SNR and subjective scores between the two groups.The examination time was shorter in group A,the difference was statistically significant(P<0.05).Image uniformity was better in group B.Conclusion The imaging effect of hard coil and flexible coil in MRI examination of the knee joint is consistent,and the examination time is shorter,which is more conducive to clinical use.