Value of ultrasound gray ratio analysis in monitoring intracranial basal ganglia of neonates with hyperbilirubinemia
10.3760/cma.j.cn131148-20231117-00231
- VernacularTitle:超声灰度比值分析对新生儿高胆红素血症颅内基底神经核监测价值初探
- Author:
Wei FENG
1
;
Jin YAN
;
Xiaoli YI
;
Ya MA
Author Information
1. 首都儿科研究所附属儿童医院超声科,北京 100020
- Keywords:
Ultrasonography, cranial;
Magnetic resonance imaging;
Hyperbilirubinemia;
Neonate
- From:
Chinese Journal of Ultrasonography
2024;33(3):247-251
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the value of cranial ultrasound (CUS) globus pallidus to putamen gray ratio(G/P) in monitoring basal ganglia of neonatal hyperbilirubinemia.Methods:A retrospective analysis was performed on the CUS, magnetic resonance imaging (MRI, 46 cases) and clinical data of 69 neonates hospitalized in the Department of Neonatology of Children′s Hospital Affiliated to Capital Institute of Pediatrics from June 2022 to June 2023. UpToDate calculator was used to calculate the reference thresholds of phototherapy for each child, combined with the 342 μmol/L node value, the children were divided into control group, mild to moderate hyperbilirubinemia group and severe hyperbilirubinemia group; RadiAnt DICOM Viewer software was used to measure the ultrasound gray values of bilateral globus pallidus and putamen, and the ratio CUS (G/P) was calculated; MRI post-processing workstation was used to read T1 signal values of bilateral globus pallidus and putamen, and the ratio MRI (G/P) was calculated. The correlations between CUS (G/P) and total serum bilirubin (TSB)/ phototherapy threshold and TSB/ albumin ratio were analyzed; the consistency of CUS (G/P) and MRI (G/P) was analyzed; the difference of CUS (G/P) among control group, light-moderate hyperbilirubinemia group and severe hyperbilirubinemia group was compared.Results:①CUS (G/P) was positively correlated with TSB/ phototherapy threshold and TSB/albumin ( rs=0.721, 0.600, all P<0.001). ②CUS (G/P) value was consistent with MRI (G/P) value (τ=0.743, P<0.05). ③CUS(G/P) value increased sequentially in the control group, mild-moderate hyperbilirubinemia group, and severe hyperbilirubinemia group, and the differences between each two groups were statistically significant (all P<0.05). Conclusions:CUS (G/P) has dose-response relationship with TSB, diagnostic agreement with MRI (G/P) value, and shows differences in different levels of bilirubin, and can be used to monitor intracranial basal ganglia in neonatal hyperbilirubinemia.