Influence of cavity design on quality of margin and marginal adaptation and microleakage of all-ceramic CAD/CAM inlays.
- Author:
Si Ming ZHAO
1
;
Xiao Yan WANG
1
Author Information
1. Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
- Publication Type:Journal Article
- Keywords:
CAD/CAM;
Cavity design;
Marginal Gap;
Marginal integrity;
Microleakage
- MeSH:
Humans;
Aged;
Molar;
Ceramics;
Computer-Aided Design;
Dental Porcelain;
Materials Testing
- From:
Journal of Peking University(Health Sciences)
2023;55(6):1105-1110
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To investigate the influence of 135° and 90° cavity design on quality of margin and marginal adaptation and microleakage of all-ceramic computer aided design/computer aided manufacturing (CAD/CAM) inlays.
METHODS:One hundred extracted human molars were prepared by criteria of buccal occlusal (BO) inlay. On the buccal, the mesial margin was prepared as 135° bevel while the distal margin was prepared as butt-joint. All-ceramic restorations were made in the Sirona CEREC AC CAD/CAM system with VitaBlocs Mark Ⅱ, Upcera UP.CAD, IPS e.max CAD, Upcera Hyramic and Lava Ultimate. The gaps between each inlay's mesial margin-abutment and distal margin-abutment were recorded under an optical microscope. Each inlay was adhered to the abutment and aged by thermal cycling for 10 000 times. Each specimen was cut into 3 slices after staining. Dye penetration was evaluated under an optical microscope for mesial and distal margins.
RESULTS:Mean marginal integrity rate, mean marginal gap value and mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group VitaBlocs Mark Ⅱ, Upcera UP.CAD and IPS e.max CAD(P < 0.05). Mean marginal gap value, mean depth of microleakage and scale of mean depth of microleakage of 90° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group Upcera UP.CAD and IPS e.max CAD (P < 0.05) while mean marginal integrity rate was not significantly different (P>0.05). Mean marginal integrity rate of 90° margin was significantly better than that of 135° margin in each group (P < 0.05) while mean depth of microleakage between different margins was not significantly different in each group (P>0.05). Mean marginal gap value of 90° margin of Group VitaBlocs Mark Ⅱ and IPS e.max CAD was significantly better than that of 135° margin (P < 0.05) while there was not significant difference in other 3 groups between 90° and 135° margin (P>0.05). Scale of mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate was significant better than that of 90° margin (P < 0.05) while there was not significantly different in other 3 groups between 90° and 135° margin (P>0.05).
CONCLUSION:The mesial and distal margins of abutement of all-ceramic inlay should be prepared as butt-joint.