1.Chemical Risk Assessment Screening Tool of a Global Chemical Company.
Evelyn TJOE-NIJ ; Christophe ROCHIN ; Nathalie BERNE ; Alessandro SASSI ; Antoine LEPLAY
Safety and Health at Work 2018;9(1):84-94
BACKGROUND: This paper describes a simple-to-use and reliable screening tool called Critical Task Exposure Screening (CTES), developed by a chemical company. The tool assesses if the exposure to a chemical for a task is likely to be within acceptable levels. METHODS: CTES is a Microsoft Excel tool, where the inhalation risk score is calculated by relating the exposure estimate to the corresponding occupational exposure limit (OEL) or occupational exposure band (OEB). The inhalation exposure is estimated for tasks by preassigned ART1.5 activity classes and modifying factors. RESULTS: CTES requires few inputs. The toxicological data, including OELs, OEBs, and vapor pressure are read from a database. Once the substance is selected, the user specifies its concentration and then chooses the task description and its duration. CTES has three outputs that may trigger follow-up: (1) inhalation risk score; (2) identification of the skin hazard with the skin warnings for local and systemic adverse effects; and (3) status for carcinogenic, mutagenic, or reprotoxic effects. CONCLUSION: The tool provides an effective way to rapidly screen low-concern tasks, and quickly identifies certain tasks involving substances that will need further review with, nevertheless, the appropriate conservatism. This tool shows that the higher-tier ART1.5 inhalation exposure assessment model can be included effectively in a screening tool. After 2 years of worldwide extensive use within the company, CTES is well perceived by the users, including the shop floor management, and it fulfills its target of screening tool.
Follow-Up Studies
;
Inhalation
;
Inhalation Exposure
;
Mass Screening*
;
Occupational Exposure
;
Politics
;
Risk Assessment*
;
Risk Management
;
Skin
;
Vapor Pressure
2.Comparative Study with Flow Regulated Valve and Differential Pressure Valve in Ventriculo-Peritoneal Shunt.
Sang Woo KIM ; Oh Lyong KIM ; Seong Ho KIM ; Jang Ho BAE ; Byung Yon CHOI ; Soo Ho CHO
Journal of Korean Neurosurgical Society 1996;25(7):1383-1388
In the management of hydrocephalus by shunts, two valve types are currently available:1) differential pressure valves(DPV) which provide a constant resistance and allow CSF flow when the proximal hydrostatic pressure exceeds the valve's present closing pressure, and 2) the newer variable resistance flow regulated valve(FRV). Eighty one cases of hydrocephalus were reviewed in this study to compare the two devices. Forty two patients were operated with FRV and 39 patients were operated with DPV. This study compared the preoperative and postoperative KPS score, ventricular size, periventricular low densities, and the frequency of complications. We have conclude that 1) In group 1(KPS score 50-70), FRV is useful and in group 2(KPS score 20-40), DPV is useful, 2) FRV is useful in dealing with excessively reduced ICP caused by over-drainage of a ventricular shunt;it can prevent postshunt subdural hygroma and symptomatic slit ventricles. 3) For evaluation of the effectiveness of FRV, the decrease of periventricular low densities is a more valuable index than the change of ventricle size(Hydrocephalus index).
Humans
;
Hydrocephalus
;
Hydrostatic Pressure
;
Subdural Effusion
;
Ventriculoperitoneal Shunt*
3.Comparison of Epidural Pressure in Pregnant Group with That of Non pregnant Group.
Jin Kyoung KIM ; Yun CHOI ; Hong KO
Korean Journal of Anesthesiology 1996;30(4):466-469
BACKGROUND: An entry of needle into the epidural space has been identified by the development of negative pressure to the advancing needle; hanging drop, loss of resistance, or use of Macintosh balloon. But it is suspicious that epidural space is a true negative pressure space. METHODS: We measured the epidural pressures of pregnant patients in right lateral decubitus (RLD) and sitting position and compared with the values of non-pregnant patients of respective position. 17G Tuohy needle with closed system was used, the pressure of which was zeroed to the puncture level at third lumbar intervertebral space. RESULTS: Epidural pressures were positive in all subjects. Values of measurement were 13+/-4mmHg, 15+/-7mmHg, 16+/-6mmHg and 25+/-7mmHg for pregnant-RLD, pregnant-sitting, non-pregnant-RLD, and non-pregnant-sitting group, respectively. CONCLUSIONS: There was a significant difference between RLD and sitting position in non-pregnant patient only (p<0.05). It is suggested that the hydrostatic pressure of CSF above puncture level and the hydrostatic pressure of valveless epidural venous plexus blood influenced the epidural pressure of non-pregnant group in sitting position. But in pregnant group, abdominal mass may have elicited a draining effect on epidural venous plexus during lumbar flexion in sitting position and partially nullified the hydrostatic pressure of CSF and blood.
Epidural Space
;
Humans
;
Hydrostatic Pressure
;
Needles
;
Pregnancy
;
Punctures
4.The effect of hydrodynamic pressure on renal cells.
Journal of Biomedical Engineering 2009;26(3):697-700
Mechanics plays an important role in regulating cell function. Hydrodynamics has become a hot topic of research in recent years. As an important factor, hydrodynamic pressure has significant influence on the form, cytoskeleton, proliferation, apoptosis and secretion function of cells. Many researches indicated that there are close relationships between kidney diseases and hydrodynamics which should be studied deeply.
Apoptosis
;
physiology
;
Cell Proliferation
;
Cytoskeleton
;
physiology
;
Humans
;
Hydrodynamics
;
Hydrostatic Pressure
;
Kidney
;
cytology
;
Pressure
5.Uncoventional Views on Certain Aspects of Toxin-Induced Metabolic Acidosis.
Electrolytes & Blood Pressure 2010;8(1):32-37
This discussion will highlight the following 9 specific points that related to metabolic acidosis caused by various toxins. The current recommendation suggests that alcohol dehydrogenase inhibitor fomepizole is preferred to ethanol in treatment of methanol and ethylene glycol poisoning, but analysis of the enzyme kinetics indicates that ethanol is a better alternative. In the presence of a modest increase in serum osmolal gap (<30 mOsm/L), the starting dose of ethanol should be far less than the usual recommended dose. One can take advantage of the high vapor pressure of methanol in the treatment of methanol poisoning when hemodialysis is not readily available. Profuse sweating with increased water ingestion can be highly effective in reducing methanol levels. Impaired production of ammonia by the proximal tubule of the kidney plays a major role in the development of metabolic acidosis in pyroglutamic acidosis. Glycine, not oxalate, is the main final end product of ethylene glycol metabolism. Metabolism of ethylene glycol to oxalate, albeit important clinically, represents less than 1% of ethylene glycol disposal. Urine osmolal gap would be useful in the diagnosis of ethylene glycol poisoning, but not in methanol poisoning. Hemodialysis is important in the treatment of methanol poisoning and ethylene glycol poisoning with renal impairment, with or without fomepizole or ethanol treatment. Severe leucocytosis is a highly sensitive indicator of ethylene glycol poisoning. Uncoupling of oxidative phosphorylation by salicylate can explain most of the manifestations of salicylate poisoning.
Acidosis
;
Alcohol Dehydrogenase
;
Ammonia
;
Eating
;
Ethanol
;
Ethylene Glycol
;
Ethylenes
;
Glycine
;
Imidazoles
;
Kidney
;
Kinetics
;
Methanol
;
Nitro Compounds
;
Oxidative Phosphorylation
;
Pyrazoles
;
Renal Dialysis
;
Sweat
;
Sweating
;
Vapor Pressure
;
Water
6.BP Values Difference Depending on the Height of Hand Position in Oscillometric Electronic Digital BP Monitor and Its Comparison with Mercury Sphygmomanometer.
Jae Min KIM ; Ju Won KWON ; Joung Min SUN ; Ja Yo JEONG ; Bong Hwa KIM ; Du Yong LEE ; Sug Joo YOON ; Chong Suhl KIM ; Young Sook KIM
Korean Circulation Journal 1992;22(6):1017-1023
BACKGROUND: There is pressure difference depending on the height of hand position when blood pressure is taken, applying the oscillometric electronic digital BP(blood pressure) monitor. Authors have calculated the degree of BP differences, and evaluated the accuracy and effectiveness of the digital BP monitor comparing with the conventional Mercury Sphygmomanometer. METHOD: Randomized sixty cases consisting of in-patients and hospital workers were subjected for this study. BPs were taken at three different levels-nose level, heart level and knee level-on conventional sitting position applying OMRON Digital Automatic Blood Pressure Monitor and conventional Mercury Sphygmomanometer, and statistical analysis was made. RESULTS: At the nose level, systolic BP and diastolic BP were lower with 23.5mmHg and 18.9mmHg respectively, than at the heart level, while at the knee level, they were higher with 21mmHg and 17.5mmHg respectively, than at the heart level. No actual statistical difference of systolic and diastolic values between OMRON Digital Automatic Blood Pressure Monitoring method at the heart level and conventional Mercury Sphygmomanometeric method. CONCLUSION: Present study demonstrated significant discrepancy of BP values, in systolic and diastolic values, depending on the height of measured finger, when OMRON Digital Automatic Blood Pressure Monitor is applied in taking BP on conventional sitting position. However, no actual discrepancy of BP values was noted between two methods when BP is taken at heart level by OMRON Digital Automatic Blood Pressure Monitor and on brachial artery BP by conventional Mercury Sphygmomanometer. Thus OMRON Digital Automatic Blood Pressure Monitor could take the place of Mercury Sphygmomanometer in taking peripheral BP, which subsequently enable us to estimate central artery BP, which is believed to be better clinical index, through this much more handy electrical oscillometric device in the future.
Arteries
;
Blood Pressure
;
Blood Pressure Monitors
;
Brachial Artery
;
Electric Impedance
;
Fingers
;
Hand*
;
Heart
;
Hydrostatic Pressure
;
Knee
;
Nose
;
Sphygmomanometers*
7.Carboxyhemoblobin Dissociation at the Various Partial Pressures of Oxygen.
Korean Journal of Preventive Medicine 1982;15(1):145-152
No abstract available.
Oxygen*
;
Partial Pressure*
8.Effects of Mechanical Stimulation and Scaffolds for Nucleus Pulposus Replacement of Intervertebral Disc.
Sang Hoon HA ; Dong Hwa KIM ; Jung Woog SHIN ; Heui Chul GWAK ; Jang Seok CHOI
Journal of Korean Orthopaedic Research Society 2009;12(2):45-52
PURPOSE: In this study, we investigated the potential of injectable hydrogel scaffolds for the regeneration of nucleus pulposus. MATERIALS AND METHODS: We prepared injectable hydrogels [Chitosan-Pluronic (CP), CP/Osteogenic Protein-1 (CP/OP-1), CP/Gly-Arg-Gly-Asp-Ser (CP/GRGDS), CP/GRGDS/OP-1] for this study. One of the four potential materials was selected through the cell viability tests. For each material, primary cultured nucleus pulposus (NP) cells from New Zealand rabbits were seeded onto each material. For the investigation of the effects of mechanical stimulation, the commercially available bioreactor was used. 0.2 MPa of intermittent hydrostatic pressure was imposed for 3 days after 7th day of seeding with the pattern of 2 min and 15 min for stimulating and resting, respectively. The specimens were harvested at 1, 10, 14 day after seeding for analyses. RESULTS: The MTT assay for 5 days revealed that CP/OP-1 group showed significant increase. The other two groups (CP/GRGDS and CP/GRGDS/OP-1) showed that the proliferation rate increased until 3 days after culture, while it decreased on day 5. The mechanical stimuli induced higher amounts of DNA measured in CP/OP- 1 on day 5 after culture. However, no significant difference was observed between two groups. CONCLUSION: We came to the conclusions that the biochemical environment as well as mechanical stimulation may play an important role in regenerating nucleus pulposus matrix, especially in CP/OP-1 in this study. However, further study are recommended in relation to mechanical effects as well as biochemical conditions.
Bioreactors
;
Cell Survival
;
DNA
;
Hydrogel
;
Hydrogels
;
Hydrostatic Pressure
;
Intervertebral Disc
;
Porphyrins
;
Rabbits
;
Regeneration
;
Seeds
9.Real-time measurement of dentinal tubular fluid flow during and after amalgam and composite restorations.
Sun Young KIM ; Byeong Hoon CHO ; Seung Ho BAEK ; Bum Sun LIM ; In Bog LEE
Journal of Korean Academy of Conservative Dentistry 2009;34(6):467-476
The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 cmH2O. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation. In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min, 3 and 7 days after restoration (P > 0.05).
Adhesives
;
Bisphenol A-Glycidyl Methacrylate
;
Dentin
;
Hydrostatic Pressure
;
Molar, Third
;
Paint
;
Resin Cements
;
Tooth
;
Tooth Cervix
10.Effects of programmed cell death on human dental follicle cells and changes of programmed cell death under different hydrostatic pressures.
Zuo-lin JIN ; Song-jiao LUO ; Zhu LIN ; Guang-hai JIAO ; Hai-xue WANG
West China Journal of Stomatology 2006;24(5):466-468
OBJECTIVETooth eruption requires the presence of the dental follicle (DF) around the unerupted tooth. This study is to investigate programmed cell death on human dental follicle cells and changes of programmed cell death under different hydrostatic pressures: 0, 50 and 100 kPa.
METHODSHuman dental follicles from third mandibular molars were surgically removed from adolescents who need for orthodontics treatment after informed content, then trypsinized and cultured. Human dental follicle cells were divided into three groups according to different hydrostatic pressures: 0, 50 and 100 kPa and their programmed cell death were labeled by using TdT-medi-ated-dUTP nick and labeling (TUNEL).
RESULTSDental follicle cells cultured were elongate shape and exhibited fibroblastic characteristics. Compared with 0 kPa, programmed cell death cells on human dental follicle cells were increased 0.23% and 31.65% under 50 kPa and 100 kPa hydrostatic pressures respectively. 100 kPa group increased significantly (P < 0.01).
CONCLUSIONIt suggested that programmed cell death occured in human dental follicle cells cultured in vitro and was influenced by different hydrostatic pressures. Hydrostatic pressure may improve tooth erup-tion through dental follicle.
Adolescent ; Apoptosis ; Dental Sac ; Fibroblasts ; Humans ; Hydrostatic Pressure ; Molar ; Tooth Eruption