2.Relationship between Anemia,Iron Deficiency and Helicobacter Pylori Infection in Children
hai-feng, DONG ; xing-xian, YANG ; yan, DING ; yuan, QIN
Journal of Applied Clinical Pediatrics 2006;0(15):-
Objective To investigate the prevalence features of helicobacter pylori (Hp) infection,anemia and iron deficiency in a po-pulation of Wuhan children with 2 to 6 years old,and the relationship between Hp infection and anemia,iron deficiency in the children.Methods Randomly taking 95 children who had taken tests in our hospital's check-up centre in 2008 as the study objects,2 kinds of exa-mination were employed to detect Hp infection.Serum levels of Hp-IgG were measured by enzyme linked immunosorbent assay (ELISA) methods to evaluate past infection.The 14C urea breath test (14C-UBT) was conducted to obtain information of the presence of current/active Hp infection.In the morning 3 mL fasting venous blood was collected to determine the serum levels of Hp-IgG antibodies and ferritin.Hemoglobin values were determined with a hemoglobinometer.Serum levels of C-reactive protein (CRP) were tested in order to determine whether the children had evidence of current inflammation or infection.In addition,demographic information such as age and gender of the children and information about their use of antibiotics within the prior month were recorded.All cases were divided into 2 groups including the Hp infection group and non-Hp infection group according to laboratory examinations,then the Logistic regression was applied to analyze the relationship between Hp infection and anemia,iron deficiency.The Kappa identity test was taked to compare the 2 measures.Results Of the 95 children,18.9% were anemic and 36.8% were iron deficient.Forty percent of the cohort had Hp-IgG antibodies,74.4% tested positive by the UBT.Presence of Hp-IgG emerged as a significant risk factor for anemia,iron deficiency in adjusted analysis controlling for demographic factors,current inflammation,and antibiotic use.Conclusions Findings from different measure of Hp may reflect different stages of infection,with UBT results reflecting an earlier stage of infection,and presence of Hp-IgG reflecting established Hp infection associated with anemia,iron deficiency.
3.Relationship between expression of follicle-stimulating hormone receptor in granulose cells and ovarian response in in vitro fertilization cycles
hai-qin, YU ; zhi-hong, NIU ; yun, FENG ; yan, LI
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(12):-
Objective To investigate relationship between levels of follicle-sitimulating horomone receptor(FSHR) and ovarian response induced by gonadotropin hormone,and whether the FSHR expression is correlated with in vitro fertilization(IVF) outcome.Methods Granulose cells were collected from 43 women receiving IVF-embryo transplantation(IVF-ET).According to the number of oocyte,the women were divided into three groups: low response(15).The expression intensity of FSHR was measured by immunohistochemistry technique.The expression intensity of FSHR on the granular cell,the embryological and clinical outcomes were compared and analyzed. Results The expression of FSHR was significantly different in three groups with the highest in high response group(P0.05).The FSHR level was positively correlated either with the number of oocyte (r=0.719) or with the serum E2 levels(r=0.516,P0.05). Conclusion Ovarian response to gonadotropin hormone stimulation is correlated with the level of FSHR in the granulose cells.The development of follicles may be influenced by it.
4.Study on Refolding Ways of Recombinant pro-Carboxypeptidase B
Xiao-Yan ZHANG ; Hai-Feng LIU ; Qin-Sheng YUAN ;
Microbiology 1992;0(02):-
dialysis.
5.Neonatal behavioral neurological assessment and developmental screening test for newborns with hypoxic ischemic encephalopathy
Xiu-qin NING ; Xiao-bing WANG ; Hai-yan MA
Chinese Journal of Rehabilitation Theory and Practice 2002;8(12):750-750
ObjectiveTo discuss the effect of neonatal behavioral neurological assessment (NBNA) and developmental screening test (DST) on newborns with hypoxic ischemic encephalopathy (HIE). MethodsNBNA was performed for 60 newborns with HIE within 12-14 days and DST was also performed at 6th month after birth.ResultsMild and severe degree HIE newborns with low NBNA scores had unfavorable prognosis. Conclusions NBNA and DST can provide evidence for early interference for newborn's HIE.
6.The mechanism of tenuigenin for eliminating waste product accumulation in cerebral neurons of Alzheimer's disease rats via ubiquitin-proteasome pathway.
Qin CHEN ; Yi-Qing CHEN ; Hai-Yan YE ; Jain-Qi YU ; Qi-Quan SHI ; Yan HUANG
Chinese Journal of Integrated Traditional and Western Medicine 2015;35(3):327-332
OBJECTIVETo explore the scavenging action of tenuigenin (TEN) on intracerebral amyloid β protein (Aβ) aggregation and the abnormal phosphorylated tau protein and its mechanism in Alzheimer's disease (AD) rats' brain.
METHODSAβ1-40 was injected into the right CA1 region hippocampus to establish the AD model. Successfully modeled rats were divided into the model group, the low, middle, high TEN group. Rats were administered with TEN (18.5, 37.0, 74.0 mg/kg) by gastrogavage. Besides, a sham-operation group was set up. Expression levels of Aβ1-40 and Tau p-Ser262 were detected by immunohistochemistry. Expression levels of ubiquitin (Ub) and Ub-protein ligase E3 were measured by Western blotting.The content of 26S proteasome was detected by ELISA.
RESULTSImmunohistochemical results showed that the number of Aβ and Tau p-Ser262 positively reacted neurons significantly increased in model group, when compared with the sham-operation group (P < 0.01). Results of Western blot showed expression levels of ubiquitinated protein were up-regulated and those of Ub-protein ligase E3 were down-regulated in the model group (P < 0.01). ELISA results showed that the content of 26S proteasome significantly decreased in AD rats' brain (P < 0.01). Compared with the model group, expression levels of Aβ1-40, Tau p-Ser262, and Ub significantly decreased; expression levels of Ub-protein ligase E3 apparently increased; the content of 26S proteasome significantly increased in each TEN treatment group (P < 0.05, P < 0.01). Best effect was shown in 37.0 mg/kg and 74.0 mg/kg TEN groups.
CONCLUSIONSUb proteasome pathway (UPP) participated in the occurrence of AD. TEN could obviously reduce intracere- bral Aβ1-40 accumulation and abnormal tau phosphorylation.
Alzheimer Disease ; metabolism ; Amyloid beta-Peptides ; Animals ; Drugs, Chinese Herbal ; pharmacology ; Hippocampus ; metabolism ; Neurons ; metabolism ; Phosphorylation ; Proteasome Endopeptidase Complex ; metabolism ; Rats ; Ubiquitin-Protein Ligases ; metabolism ; Ubiquitins
7.Application of contrast-enhanced ultrasound in preoperative diagnosis of anal fistula
Dazhong ZOU ; Yifeng YU ; Danping YAN ; Li LIU ; Qin XUE ; Yufang XU ; Yuying TANG ; Hai GONG
Chinese Journal of Ultrasonography 2010;19(12):1051-1053
Objective To evaluate the clinical value of contrast-enhanced ultrasound (CEUS) in preoperative diagnosis of anal fistula. Methods Forty-five patients with fistula in ano were evaluated by physical examination, then CEUS were peformed by injecting SonoVue through the external opening to enhance the detection of the fistulous track and the internal opening. The results of CEUS were matched with surgical features to establish their accuracy in preoperative assessment of anal fistula. Results Simple typing fistula was found in 19 of 45 patients and 26 patients had complex fistulas. The accurate diagnostic rates by conventional ultrasound of simple typing fistula and complex fistulas were 89. 5% and 61.5%,respectively,the accurate diagnostic rates by CEUS of simple typing fistula and complex fistulas were 94. 7% and 92.3%, respectively, there was no significant difference between conventional ultrasound and CEUS about simple typing fistula( P >0.05), and there was significant difference about complex fistulas ( P <0. 05). Conclusions CEUS has a good visibility and accurate rate for diagnosis of anal fistula,It plays an important role for operation.
8.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
9.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
10.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.