1.Hypolipidemic effect and mechanism of Arisaema Cum Bile based on gut microbiota and metabolomics.
Peng ZHANG ; Fa-Zhi SU ; En-Lin ZHU ; Chen-Xi BAI ; Bao-Wu ZHANG ; Yan-Ping SUN ; Hai-Xue KUANG ; Qiu-Hong WANG
China Journal of Chinese Materia Medica 2025;50(6):1544-1557
Based on the high-fat diet-induced hyperlipidemia rat model, this study aimed to evaluate the lipid-lowering effect of Arisaema Cum Bile and explore its mechanisms, providing experimental evidence for its clinical application. Biochemical analysis was used to detect serum levels of alanine aminotransferase(ALT), aspartate aminotransferase(AST), high-density lipoprotein cholesterol(HDL-C), low-density lipoprotein cholesterol(LDL-C), triglycerides(TG), and total cholesterol(TC) to assess the lipid-lowering activity of Arisaema Cum Bile. Additionally, 16S rDNA sequencing and metabolomics techniques were employed to jointly elucidate the lipid-lowering mechanisms of Arisaema Cum Bile. The experimental results showed that high-dose Arisaema Cum Bile(PBA-H) significantly reduced serum ALT, AST, LDL-C, TG, and TC levels(P<0.01), and significantly increased HDL-C levels(P<0.01). The effect was similar to that of fenofibrate, with no significant difference. Furthermore, Arisaema Cum Bile significantly alleviated hepatocyte ballooning and mitigated fatty degeneration in liver tissues. As indicated by 16S rDNA sequencing results, PBA-H significantly enhanced both alpha and beta diversity of the gut microbiota in the model rats, notably increasing the relative abundance of Akkermansia and Subdoligranulum species(P<0.01). Liver metabolomics analysis revealed that PBA-H primarily regulated pathways involved in arachidonic acid metabolism, vitamin B_6 metabolism, and steroid biosynthesis. In summary, Arisaema Cum Bile significantly improved abnormal blood lipid levels and liver pathology induced by a high-fat diet, regulated hepatic metabolic disorders, and improved the abundance and structural composition of gut microbiota, thereby exerting its lipid-lowering effect. The findings of this study provide experimental evidence for the clinical application of Arisaema Cum Bile and the treatment of hyperlipidemia.
Animals
;
Gastrointestinal Microbiome/drug effects*
;
Rats
;
Male
;
Metabolomics
;
Hyperlipidemias/microbiology*
;
Drugs, Chinese Herbal/administration & dosage*
;
Rats, Sprague-Dawley
;
Hypolipidemic Agents/pharmacology*
;
Liver/metabolism*
;
Humans
;
Alanine Transaminase/metabolism*
;
Triglycerides/metabolism*
;
Aspartate Aminotransferases/metabolism*
2.Exploring Mechanism of Electroacupuncture in Modulating Neuroinflammation Based on Intestinal Flora and Its Metabolites.
Hai-Min YE ; Zhuo-Yan LI ; Peng ZHANG ; Zhen KANG ; De-Sheng ZHOU
Chinese journal of integrative medicine 2025;31(2):183-192
Neuroinflammatory responses play an important role in the pathogenesis of various diseases, particularly those affecting the central nervous system. Inhibition of neuroinflammation is a crucial therapeutic strategy for the management of central nervous system disorders. The intestinal microbial-gut-brain axis serves as a key regulatory pathway that modulates neuroinflammatory processes. Intestinal flora metabolites such as short-chain fatty acids, indoles and their derivatives, lipopolysaccharides, trimethylamine oxide, and secondary bile acids exert direct or indirect effects on neuroinflammation. Studies have shown that electroacupuncture (EA) modulates the composition of the intestinal microbiota and its metabolites, while also suppressing neuroinflammation by targeting the TLR4/NF- κ B, NLRP3/caspase-1, and microglial cell M2-type transformation pathways. This review discusses the mechanisms by which EA regulates neuroinflammation via intestinal microbiota and its metabolites, providing information and a foundation for further investigation of the precise therapeutic mechanisms of EA in neurological disorders.
Humans
;
Gastrointestinal Microbiome
;
Electroacupuncture
;
Neuroinflammatory Diseases/metabolism*
;
Animals
3.Electrophysiological Signatures of Visual Sensations Elicited by Direct Electrical Stimulation.
Yan-Yan LI ; Bo ZHANG ; Jing WANG ; Yuri B SAALMANN ; Mohsen AFRASIABI ; Peng-Cheng LV ; Hai-Xiang WANG ; Huan-Huan XIANG ; Meng-Yang WANG ; Guo-Ming LUAN ; Robert T KNIGHT ; Liang WANG
Neuroscience Bulletin 2025;41(9):1617-1629
Direct electrical stimulation of the human cortex can produce subjective visual sensations, yet these sensations are unstable. The underlying mechanisms may stem from differences in electrophysiological activity within the distributed network outside the stimulated site. To address this problem, we recruited 69 patients who experienced visual sensations during invasive electrical stimulation while intracranial electroencephalography (iEEG) data were recorded. We found significantly flattened power spectral slopes in distributed regions involving different brain networks and decreased integrated information during elicited visual sensations compared with the non-sensation condition. Further analysis based on minimum information partitions revealed that the reconfigured network interactions primarily involved the inferior frontal cortex, posterior superior temporal sulcus, and temporoparietal junction. The flattened power spectral slope in the inferior frontal gyrus was also correlated with integrated information. Taken together, this study indicates that the altered electrophysiological signatures provide insights into the neural mechanisms underlying subjective visual sensations.
Humans
;
Male
;
Female
;
Adult
;
Visual Perception/physiology*
;
Electric Stimulation
;
Middle Aged
;
Young Adult
;
Electrocorticography
;
Electroencephalography
;
Brain Mapping
4.Generalized Functional Linear Models: Efficient Modeling for High-dimensional Correlated Mixture Exposures.
Bing Song ZHANG ; Hai Bin YU ; Xin PENG ; Hai Yi YAN ; Si Ran LI ; Shutong LUO ; Hui Zi WEIREN ; Zhu Jiang ZHOU ; Ya Lin KUANG ; Yi Huan ZHENG ; Chu Lan OU ; Lin Hua LIU ; Yuehua HU ; Jin Dong NI
Biomedical and Environmental Sciences 2025;38(8):961-976
OBJECTIVE:
Humans are exposed to complex mixtures of environmental chemicals and other factors that can affect their health. Analysis of these mixture exposures presents several key challenges for environmental epidemiology and risk assessment, including high dimensionality, correlated exposure, and subtle individual effects.
METHODS:
We proposed a novel statistical approach, the generalized functional linear model (GFLM), to analyze the health effects of exposure mixtures. GFLM treats the effect of mixture exposures as a smooth function by reordering exposures based on specific mechanisms and capturing internal correlations to provide a meaningful estimation and interpretation. The robustness and efficiency was evaluated under various scenarios through extensive simulation studies.
RESULTS:
We applied the GFLM to two datasets from the National Health and Nutrition Examination Survey (NHANES). In the first application, we examined the effects of 37 nutrients on BMI (2011-2016 cycles). The GFLM identified a significant mixture effect, with fiber and fat emerging as the nutrients with the greatest negative and positive effects on BMI, respectively. For the second application, we investigated the association between four pre- and perfluoroalkyl substances (PFAS) and gout risk (2007-2018 cycles). Unlike traditional methods, the GFLM indicated no significant association, demonstrating its robustness to multicollinearity.
CONCLUSION
GFLM framework is a powerful tool for mixture exposure analysis, offering improved handling of correlated exposures and interpretable results. It demonstrates robust performance across various scenarios and real-world applications, advancing our understanding of complex environmental exposures and their health impacts on environmental epidemiology and toxicology.
Humans
;
Environmental Exposure/analysis*
;
Linear Models
;
Nutrition Surveys
;
Environmental Pollutants
;
Body Mass Index
5.Development of biological safety protection third-level laboratory based on folding-modular shelters
Si-Qing ZHAO ; Jian-Qiao XIA ; Zhong-Jie SUN ; Kang OUYANG ; Xiao-Jun JIN ; Kang-Li ZHOU ; Wei XIE ; Hai-Yang LI ; Da-Peng JIANG ; Yan-Yan GAO ; Bei SUN
Chinese Medical Equipment Journal 2024;45(3):41-46
Objective To develop a biological safety protection third-level(BSL-3)laboratory based on folding-modular shelters to solve the problems of the existing laboratories in space and function expansion,large-scale deployment and low-cost transportation.Methods The BSL-3 laboratory was composed of a folding combined shelter module,a ventilation and purification module,a power supply and distribution module,a monitoring and communication module,a control system module and an equipment module.The folding combined shelter module used a leveling base frame as the foundation and a lightweight panel as the enclosure mechanism,and was divided into an auxiliary area and a protection protected area;the ventilation and purification module was made up of an air supply unit and an air exhaust unit,the air supply unit was integrated with a fresh-air air conditioner and the exhaust unit was equipped with a main fan,a standby fan and a bag in/bag out filter;the control system module adopted a supervision mode of decentralized control and centralized management,which executed communication with the data server as the center and Profinet protocol and MODBUS-TCP.Results The BSL-3 laboratory proved to meet the requirements of relevant standards in internal microenvironment,airflow direction,airtightness,working condition and disinfection effect.Conclusion The BSL-3 laboratory is compatible with large-scale transport and deployment and facilitates reliable and safe experiments for epidemic prevention and control and cross-regional support.[Chinese Medical Equipment Journal,2024,45(3):41-46]
6.Design of portable collection device for exhaled breath condensate
An XIANG ; Lei ZHOU ; Qi-Feng JI ; Yuan-Zhe LI ; Qin WANG ; Shi-Man ZHU ; Jie PENG ; Xiao-Ying LEI ; Wei-Na LI ; Li WANG ; Yan-Hai GUO ; Zi-Fan LU
Chinese Medical Equipment Journal 2024;45(8):32-37
Objective To develop a portable collection device of human exhaled breath condensate(EBC)based on natural breathing to meet the needs for rapid screening of human respiratory tract(especially lower respiratory tract)infections.Methods The device consisted of a refrigeration unit,a heat dissipation unit and a condensation unit.The refrigeration unit adopted a TES1-7102 thermoelectric Peltier cooler semiconductor as the refrigeration element;the heat dissipation unit was composed of a high thermal conductivity aluminum heat sink and a high-speed brushless cooling fan;the condensation unit was made up of a cold guide plate and a condenser,in which the cold guide plate was made of thin sheet of aluminum alloy,and the condenser was prepared by 3D printing technology and made of hydrophobic polylactic acid,with primary and secondary 2-stage guide grooves and an ultra-thin condensing surface.The performance of the device was verified in terms of cooling,thermal conductivity,condensation and human EBC collection and content analysis.Results Performance analysis showed that after refrigeration began the temperature difference between the condenser surface and the exhaled gas met the requirements of the condenser,and no obvious thermal resistance was found on the condensing surface so that large droplets could be formed rapidly and then be collected after the gas-liquid phase change of the exhaled gas on the condensing surface.Human EBC collection and content analysis indicated the device realized home self-collection of EBCs from people of all ages,and the concentrations of interleukins,C-reactive protein and other inflammation-related indexes and the pH value of the collected EBC samples were all correlated with respiratory infections in the subjects.Conclusion The device developed with easy operation avoids the discomfort of blowing collection and the risk of saliva contamination,and is worthy promoting for rapid diagnosis and dynamic monitoring of respiratory tract infection and other related diseases.[Chinese Medical Equipment Journal,2024,45(8):32-37]
7.Comparative study of total knee arthroplasty assisted by robot and remote sensing navigation system
Hai TANG ; Hong-Mei ZHANG ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Yuan-Yuan LI ; Xin-Yue WANG ; Si-Ye LIU ; Ming-Jiang HE
China Journal of Orthopaedics and Traumatology 2024;37(9):862-869
Objective To compare clinical efficacy of robot-assisted(RA)and remote sensing navigation alignment(RSNA)system-assisted total knee arthroplasty(TKA).Methods From March 2023 to June 2023,60 patients who underwent the first unilateral TKA due to severe knee osteoarthritis(KOA)were admitted and divided into RSNA group and RA group according to different treatment methods,with 30 patients in each group.There were 5 males and 25 females in RSNA group,aged from 56 to 81 years old with an average of(66.33±7.16)years old;body mass index(BM1)ranged from 19.87 to 38.54 kg·m-2 with an average of(28.40±6.18)kg·m-2;the courses of disease ranged from 5 to 36 months with an average of(18.20±8.98)months;RSNA system was used to assist the positioning of osteotomy.There were 7 males and 23 females in RA group,aged from 55 to 82 years old with an average of(67.83±8.61)years old;BMI ranged from 19.67 to 37.25 kg·m-2 with an aver-age of(28.01±4.89)kg·m-2;the courses of disease ranged from 3 to 33 months with an average of(17.93±9.20)months;RA was performed.Operation time,incision length,latent blood loss at 2 weeks after operation and incidence of lower extremity thrombosis were compared between two groups.Hip-knee ankle angle(HKAA),HKAA deviation,lateral distal femoral angle(LDFA),medial proximal tibial angle(MPTA)and posterior tibial slope(PTS)were compared between two groups;Western Ontario McMaster Universities Osteoarthritis Index(WOMAC)and Knee Society score(KSS)were used to evaluate functional recovery before operation,3 and 6 months after operation.Results The operation was performed successfully in both groups,and there were no serious complications such as vascular and nerve injury during operation.The wound healed well at stage Ⅰafter operation,and the follow-up time was 6 months.The operation time,latent blood loss at 2 weeks after operation and inci-sion length in RSNA group were(94.35±5.75)min,(130.54±17.53)mland(14.73±2.14)cm,respectively;while(102.57±6.88)min,(146.33±19.47)ml and(16.78±2.32)cm in RA group,respectively.RSNA group was better than RA group(P<0.05).No deep vein thrombosis occurred in both groups at 2 weeks after operation,5 patients occurred intermuscular vein throm-bosisin in RSNA group and 8 patients in RA group,the difference was not statistically significant(P>0.05).In RSNA group,HKAA,LDFA and MPTA were(173.00±5.54)°,(86.96±3.45)°,(82.79±3.35)° before operation,and(178.34±1.85)°,(89.92±0.42)°,(89.84±0.73)° at 1 week after operation,respectively.In RA group,HKAA,LDFA and MPTA were(173.31±6.48)°,(87.15±3.40)° and(82.99±3.05)° before operation,and(178.52±1.79)°,(90.03±0.39)° and(90.15±0.47)° at 1 week after operation,respectively.HKAA,LDFA and MPTA were significantly improved in both groups at 1 week after oper-ation(P<0.05).There were no significant difference in HKAA,LDFA,MPTA and PTS between two groups before operation and 1 week after operation(P>0.05).There was no significant difference in deviation distribution of HKAA at 1 week after op-eration(x2=2.61 1,P=0.456).There were no significant difference in WOMAC and KSS between two groups before operation,3 and 6 months after operation(P>0.05),and postoperative WOMAC and KSS at 3 and 6 months between two groups were im-proved compared with those before operation(P<0.05).Conclusion Both RA and RSNA system assisted TKA could obtain ac-curate osteotomy,RA has higher surgical accuracy,RSNA system assisted operation has less trauma,and operation is simpler.
8.Application of remote sensing navigation system in total knee arthroplasty
Yuan-Yuan LI ; Ming-Jiang HE ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Hai TANG ; Xin-Yue WANG ; Si-Ye LIU ; Hong-Mei ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):878-885
Objective To explore clinical accuracy of remote sensing navigation alignment(RSNA)system in total knee arthroplasty(TKA)and its influence on postoperative clinical efficacy.Methods From May 2021 to May 2022,60 knee os-teoarthritis(KOA)patients with Kellgren-Lawrence(K-L)grade Ⅲ to Ⅳ treated by unilateral primary TKA were selected and divided into RSNA group and traditional operation group according to treatment methods,and 30 patients in each group.There were 6 males and 24 females in RSNA group,aged from 55 to 86 years old with an average of(68.06±8.23)years old;body mass index(BMI)ranged from 22.15 to 34.58 kg·m-2 with an average of(28.20±3.01)kg·m-2;the courses of disease ranged from 2 to 60 months with an average of(18.80±14.80)months;13 patients with grade Ⅲ and 17 patients with grade Ⅳaccording to K-L grading.In traditional operation group,there were 8 males and 22 females,aged from 57 to 85 years old with an average of(67.26±6.32)years old;BMI ranged from 23.94 to 34.55 kg·m-2 with an average of(27.49±2.32)kg·m-2;the courses of disease ranged from 3 to 60 months with an average of(21.30±16.44)months;14 patients with grade Ⅲ and 16 pa-tients with grade Ⅳ according to K-L grading.Western Ontario and McMaster Universities(WOMAC)osteoarthritis index and Knee Society score(KSS)were used to evaluate functional recovery of patients.Hip-knee-ankle angle(HKAA),distal femoral valgus angle(FVA)and distal fermoral flexion angle(DFFA)were measured before operation.HKAA and HKAA deviation angle were measured at 1 week after operation,and defective rate of lower limb force line,femur prosthesis valgus angle(FP-VA)and femoral prosthesis flexion angle(FPFA),respectively,were calculated.Results There were no serious complications such as vascular and nerve injury during operation,and wound healed at stage Ⅰ.Both groups were followed up for 6 months.There were no significant difference in WOMAC index,KSS,HKAA,FVA and DFFA between two groups before operation(P>0.05).The force line defect rate,HKAA,HKAA deviation angle,FPVA deviation angle and FPFA of RSNA group were 6.7%,(178.74±1.56)°,(1.25±1.56)°,(1.84±0.16)° and(4.85±2.46)°,respectively;while in traditional operation group were 20%,(176.73±3.46)°,(3.27±3.46)°,(2.44±0.26)°,(6.60±1.86)°;the difference between two groups were statistically sig-nificant(P<0.05).There were no significant difference in WOMAC index and KSS between two groups at 3 and 6 months after operation(P>0.05).Conclusion RSNA system could reduce defective rate of lower limb force line,FPVA deviation angle and FPFA after TKA,which is more accurate and easy to operate than traditional intramedullary localization surgery while ensuring postoperative efficacy.
9.Predictive value of balanced steady-state free precession MRI combined with IVIM-DWI and Gd-DTPA enhancement for extramural vascular status in rectal cancer
Jun ZHANG ; Hai-Qing ZHANG ; Yan-Jun LIU ; Peng XIA ; Bing YU ; Hui-Jie ZHA
Chinese Journal of Current Advances in General Surgery 2024;27(5):369-372
Objective:To investigate the predictive value of MRI balanced steady-state free precession(b SSFP)synergistic voxel incoherent motion diffusion weighted imaging(IVIM-DWI)and Gd-DTPA enhanced scanning for the status of extramural vascular invasion(EMVI)in rectal cancer before surgery.Methods:A total of 105 rectal cancer patients from the People's Hospital of Lujiang County,Anhui Province,were retrospectively selected and included.All patients were confirmed by postoperative pathology and underwent preoperative b SSFP sequences,IVIM-DWI functional imaging,and Gd-DTPA-enhanced multiparameter MRI scans.Three seven-point schemes based on individual b SSFP sequences,IVIM-DWI functional imaging,and Gd-DTPA en-hancement,two-by-two synergy,and multi-sequence combined diagnosis were utilized in con-junction with conventional MRI sequences for preoperative prediction of EMVI status.The diag-nostic efficacy of T2WI and b SSFP sequences was compared with that of postoperative patho-logic results.ROC curves were plotted to obtain the corresponding area under the ROC curve(AUC),specificity,and sensitivity.Results:The AUC for predicting the preoperative vascular status outside the rectal wall was 0.572(95%CI:0.408~0.737)for the conventional T2 lipid sup-pression sequence,with a specificity of 0.811 and a sensitivity of 0.667.The AUC for the b SSPF sequence was 0.817(95%CI:0.680~0.954),with a specificity of 0.900 and a sensitivity of 0.733.All of the statistical parameters were higher than the diagnostic efficacy of conventional T2 lipid suppression sequences.The multi-sequence MRI co-diagnosis had an AUC of 0.961(95%CI:0.886~1.000),with a specificity of 0.988 and a sensitivity of 0.875(P<0.05).Conclusion:Mag-netic resonance b SSFP sequence synergized with IVIM-DWI and Gd-DTPA-enhanced multipa-rameter scanning has high clinical application value for the preoperative prediction of EMVI inva-sion in rectal cancer.
10.Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fracture with kyphotic deformity in the elderly (version 2024)
Jian CHEN ; Qingqing LI ; Jun GU ; Zhiyi HU ; Shujie ZHAO ; Zhenfei HUANG ; Tao JIANG ; Wei ZHOU ; Xiaojian CAO ; Yongxin REN ; Weihua CAI ; Lipeng YU ; Tao SUI ; Qian WANG ; Pengyu TANG ; Mengyuan WU ; Weihu MA ; Xuhua LU ; Hongjian LIU ; Zhongmin ZHANG ; Xiaozhong ZHOU ; Baorong HE ; Kainan LI ; Tengbo YU ; Xiaodong GUO ; Yongxiang WANG ; Yong HAI ; Jiangang SHI ; Baoshan XU ; Weishi LI ; Jinglong YAN ; Guangzhi NING ; Yongfei GUO ; Zhijun QIAO ; Feng ZHANG ; Fubing WANG ; Fuyang CHEN ; Yan JIA ; Xiaohua ZHOU ; Yuhui PENG ; Jin FAN ; Guoyong YIN
Chinese Journal of Trauma 2024;40(11):961-973
The incidence of osteoporotic thoracolumbar vertebral fracture (OTLVF) in the elderly is gradually increasing. The kyphotic deformity caused by various factors has become an important characteristic of OTLVF and has received increasing attention. Its clinical manifestations include pain, delayed nerve damage, sagittal imbalance, etc. Currently, the definition and diagnosis of OTLVF with kyphotic deformity in the elderly are still unclear. Although there are many treatment options, they are controversial. Existing guidelines or consensuses pay little attention to this type of fracture with kyphotic deformity. To this end, the Lumbar Education Working Group of the Spine Branch of the Chinese Medicine Education Association and Editorial Committee of Chinese Journal of Trauma organized the experts in the relevant fields to jointly develop Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fractures with kyphotic deformity in the elderly ( version 2024), based on evidence-based medical advancements and the principles of scientificity, practicality, and advanced nature, which provided 18 recommendations to standardize the clinical diagnosis and treatment.

Result Analysis
Print
Save
E-mail