1.Effects of propranolol on femoral fracture healing in mice via miR-92a-3p
Jin ZHANG ; Zhi-Wei CHEN ; Sheng-Zhong XUE ; Wen-Jie ZHOU ; Jiu-Xia WANG ; Jian-Jun SHEN
The Chinese Journal of Clinical Pharmacology 2024;40(20):3028-3032
Objective To explore the effect of propranolol on femoral fracture healing in mice through regulation of microRNA-92a-3p(miR-92a-3p)and its mechanism.Methods C57BL/6J male mice were randomly divided into sham group(equal amount of 0.9%NaCl),model group(equal amount of 0.9%NaCl),experimental group(50 mg·kg-1 propranolol administration),inhibitor group(mice were injected with 100 mg·kg-1 miR-92a-3p inhibitor via tail vein on the basis of the experimental group).Femur was severed and molded in all mice except sham operation group.X-ray was used to observe bone healing.Quantitative real time polymerase chain reaction was used to detect the expression of miR-92a-3p in femur tissues.The expression level of bone formation and bone metabolism markers was detected by enzyme linked immunosorbent assay.Western blot was used to detect the expression of pathway-related proteins.Results The X-ray scores of femur in sham group,model group and experimental group were 11.20±2.60,4.70±1.50 and 9.60±2.40,respectively;the relative expression levels of miR-92a-3p in sham operation group,model group,experimental group and inhibitor group were 1.00±0.09,0.73±0.06,0.90±0.07 and 0.78±0.06;alkaline phosphatase levels were(35.21±2.63),(43.16±3.29),(67.58±5.37)and(49.62±4.05)U·L-1,respectively;crosslaps levels were(4.57±0.52),(8.41±0.91),(4.26±0.67)and(5.73±0.84)ng·mL-1,respectively;the relative expression levels of brain derived neurotrophic factor were 1.00±0.14,0.58±0.05,0.83±0.09 and 0.71±0.06,respectively;the relative expression levels of phospho-tyrosine kinase receptor B were 1.00±0.12,0.62±0.05,0.89±0.08 and 0.76±0.07,respectively;the relative expression levels of phospho-extracellular regulated protein kinases were 1.00±0.11,0.54±0.04,0.78±0.07 and 0.65±0.05,respectively.The above indexes in the model group were compared with those in the sham group,those in the experimental group were compared with those in the model group,and those in the inhibitor group were compared with those in the experimental group,and the differences were statistically significant(P<0.05,P<0.001).Conclusion Propranolol can promote femoral fracture healing in mice,which may be achieved by up-regulating miR-92a-3p activation of brain derived neurotrophic factor/tyrosine kinase receptor B/extracellular regulated protein kinases signaling pathway.
2.Human infective endocarditis caused by Bartonella vinsonii subsp.berk-hoffii:one case report and literature review
Jun-Yan YAN ; Rui-Yan MA ; Ying-Bin XIAO ; Jia HAO ; Ming-Wen LI ; Jian LI ; Lin CHEN ; Ying-Jiu JIANG
Chinese Journal of Infection Control 2024;23(10):1295-1301
Objective To explore the clinical characteristics and treatment strategies of infective endocarditis caused by Bartonella vinsonii subsp.berkhoffii(Bvb).Methods Clinical diagnosis and treatment of a 25-year-old male patient with infective endocarditis caused by Bvb in China was reported,combined with literatures about three similar cases reported abroad were summarized and analyzed.Results All 4 patients were young and middle-aged males with a history of close contact with canines in the past one year.The main symptoms were chest pain,fa-tigue,and dyspnea,accompanied by cerebrovascular accidents and severe anemia,as well as the formation of heart valve vegetations and valve function impairment.Multiple blood cultures were negative,2 and 3 cases were con-firmed to be infected with Bvb through metagenomic next-generation sequencing(mNGS)of pathogenic microorga-nisms and polymerase chain reaction respectively.All patients underwent surgical treatment due to heart failure,and all survived after surgery and targeted anti-infective treatment.Conclusion This case report is the first case of Bvb infective endocarditis in China.Patient's diagnosis is confirmed by serum indirect immunofluorescence assay and mNGS,combination of surgery and anti-infective treatment has achieved ideal effect.
3.Therapeutic Effect of Canagliflozin on Nephrotic Syndrome and Its Ultrasonic Evaluation
Wen-juan HONG ; Hong-jun LI ; Jiu-lin ZOU ; Wei HUAN ; Xiao LI ; Jia-mao CHENG ; Hai-yan CHEN
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(1):71-77
ObjectiveTo investigate the therapeutic effect of antidiabetic drug canagliflozin (CGLZ) on adriamycin-induced nephrotic syndrome (NS) in rats, and the evaluation of contrast-enhanced ultrasound (CEUS) combined with color Doppler flow imaging (CDFI) during the treatment. MethodsA total of 56 male SD rats were randomly divided into normal group (NG), model group (MG), prednisone (PAT) group (PG), low-dose single CGLZ group (LSCG), high-dose single CGLZ group (HSCG), low-dose CGLZ + PAT group (LUCG) and high-dose CGLZ + PAT group (HUCG), with 8 rats in each group. The NS model in rats was induced by injecting adriamycin twice into the tail vein, and then the NS rats were treated by intragastric administration daily for 6 weeks with reference of PAT. Twenty-four hour urine total protein (24 h-UTP) was assessed one day before the start of oral administration and at the end of 2, 4 and 6 weeks after oral administration, respectively. CDFI and CEUS were performed on the right renal artery at the end of 6 weeks after oral administration, and the blood of abdominal aorta was taken for serological test the next day. ResultsCompared with those detection index of NG rats, the 24-hour UTP of MG rats increased (P<0.01), the serum ALB decreased and TG, TC, LDL increased (P<0.01), and CDFI shows that RRCT was thinner (P<0.01) and the renal artery blood flow indicators RA-PI, RA-RI, RA-S/D all increased (P<0.05), and CEUS image shows that the TIC curve parameters TTP, AT, AUC all increased and DPI decrease in MG rats (P<0.01). After drug treatment, compared with those detection index of MG rats, 24 h-UTP decrease in LSCG after 2 weeks (P<0.01), and decrease significantly in all drug groups after 6 weeks (P<0.01); the serological test results show that the serum ALB in all CGLZ groups increased (P<0.05), TG decrease in LSCG (P<0.01), TC and LDL also decrease in LUCG after 6 weeks (P<0.05); CDFI shows that the RRCT thinning degree in all CGLZ is reduced (P<0.01), and the RA-PI in LSCG, RA-RI in PG, and RA-S/D in PG, LSCG, HSCG and LUCG rats all decreased (P<0.05); CEUS shows that the TTP, AT and AUC of renal TIC curve in drug treatment groups all decreased (P<0.01), and the DPI in PG, HSCG, LUCG and HUCG rats increased (P<0.01). ConclusionsCGLZ has the effect of treating NS, and the small dose is the best. CEUS combined with CDFI can be used to evaluate the renal morphology and hemodynamic changes of NS model rats before and after drug treatment, which is helpful to guide clinical application.
4.Clinical application of ArcScan Insight 100 very high-frequency digital ultrasound scanner in ophthalmology
Wen-Fang LIU ; Hao WANG ; Peng SONG ; Chen-Jiu PANG
International Eye Science 2023;23(3):425-429
ArcScan Insight 100 very high-frequency(VHF)digital ultrasound scanner is a new ocular ultrasonic measuring instrument, which can detect and measure the anterior segment. It can be used for screening before corneal refractive surgery and follow-up after corneal refractive surgery, measuring anterior segment parameters before implantable collamer lens(ICL)implantation, predicting preoperative vault, measuring postoperative vault, early screening keratoconus, and diagnosing glaucoma, cataract and eye injuries, etc. Taking the advantages of a wide range examination of ultrasound biomicroscope(UBM)and simple operation of optical coherence tomography(OCT), it has a broad prospect for clinical application. In this paper, the measurement principle, application method, parameters and clinical application progress of ArcScan Insight 100 VHF digital ultrasound scanner are reviewed in detail.
5.Delivery room resuscitation and short-term outcomes of extremely preterm and extremely low birth weight infants: a multicenter survey in North China.
Shuai-Jun LI ; Qi FENG ; Xiu-Ying TIAN ; Ying ZHOU ; Yong JI ; Yue-Mei LI ; Shu-Fen ZHAI ; Wei GUO ; Fang ZHANG ; Rong-Xiu ZHENG ; Hai-Ying HE ; Xia LIU ; Jun-Yi WANG ; Hua MEI ; Hong-Yun WANG ; Hua XIE ; Chao-Mei ZENG ; Li MA ; Ping-Ping ZHANG ; Jin-Yu LI ; Xiao-Ying WANG ; Li-Hua LI ; Hong CUI ; Shu-Lan YANG ; Lu CHEN ; Xiao-Hong GU ; Yan-Ju HU ; Sheng-Shun QUE ; Li-Xia SUN ; Ming YANG ; Wen-Li ZHAO ; Qiu-Yan MA ; Hai-Juan WANG ; Jiu-Ye GUO
Chinese Medical Journal 2021;134(13):1561-1568
BACKGROUND:
Delivery room resuscitation assists preterm infants, especially extremely preterm infants (EPI) and extremely low birth weight infants (ELBWI), in breathing support, while it potentially exerts a negative impact on the lungs and outcomes of preterm infants. This study aimed to assess delivery room resuscitation and discharge outcomes of EPI and ELBWI in China.
METHODS:
The clinical data of EPI (gestational age [GA] <28 weeks) and ELBWI (birth weight [BW] <1000 g), admitted within 72 h of birth in 33 neonatal intensive care units from five provinces and cities in North China between 2017 and 2018, were analyzed. The primary outcomes were delivery room resuscitation and risk factors for delivery room intubation (DRI). The secondary outcomes were survival rates, incidence of bronchopulmonary dysplasia (BPD), and risk factors for BPD.
RESULTS:
A cohort of 952 preterm infants were enrolled. The incidence of DRI, chest compressions, and administration of epinephrine was 55.9% (532/952), 12.5% (119/952), and 7.0% (67/952), respectively. Multivariate analysis revealed that the risk factors for DRI were GA <28 weeks (odds ratio [OR], 3.147; 95% confidence interval [CI], 2.082-4.755), BW <1000 g (OR, 2.240; 95% CI, 1.606-3.125), and antepartum infection (OR, 1.429; 95% CI, 1.044-1.956). The survival rate was 65.9% (627/952) and was dependent on GA. The rate of BPD was 29.3% (181/627). Multivariate analysis showed that the risk factors for BPD were male (OR, 1.603; 95% CI, 1.061-2.424), DRI (OR, 2.094; 95% CI, 1.328-3.303), respiratory distress syndrome exposed to ≥2 doses of pulmonary surfactants (PS; OR, 2.700; 95% CI, 1.679-4.343), and mechanical ventilation ≥7 days (OR, 4.358; 95% CI, 2.777-6.837). However, a larger BW (OR, 0.998; 95% CI, 0.996-0.999), antenatal steroid (OR, 0.577; 95% CI, 0.379-0.880), and PS use in the delivery room (OR, 0.273; 95% CI, 0.160-0.467) were preventive factors for BPD (all P < 0.05).
CONCLUSION
Improving delivery room resuscitation and management of respiratory complications are imperative during early management of the health of EPI and ELBWI.
Birth Weight
;
Bronchopulmonary Dysplasia
;
China/epidemiology*
;
Delivery Rooms
;
Female
;
Gestational Age
;
Humans
;
Infant
;
Infant, Extremely Low Birth Weight
;
Infant, Extremely Premature
;
Infant, Newborn
;
Male
;
Pregnancy
7.Arthritis, Dyspnea and Hemoptysis on Exertion
Zi1 WANG ; Bing-Bin2 ZHAO ; Jiu-Liang3 ZHAO ; Hua3 CHEN ; Guo-Tao4 MA ; Jian-Zhou4 LIU ; Wen-Qian5 CHEN ; Chi6 SHAO ; Jin-Zhi7 LAI ; Wei8 CHENG ; Qi4 MIAO ; Xiao-Feng3 ZENG ; Feng-Chun3 ZHANG ; Jin-Jing3 LIU
Medical Journal of Peking Union Medical College Hospital 2020;11(3):347-353
Intracardiac thrombus is a rare complication of Antiphospholipid syndrome secondary to systemic lupus erythematosus (SLE). Its treatment is extremely tough and requires a multidisciplinary approach. We reported a case of SLE with intracardiac thrombus and pulmonary embolism. The patient was complicated with hemoptysis and kidney injury,and had a high risk of sudden death from incidental thrombus shedding off. In the state of thrombosis and hemorrhage,the management of anticoagulation and the evaluation and treatment of the primary disease complicated with infection are challenging. The multidisciplinary collaboration helped us to create a more favorable surgical condition while controlling SLE aggressively. After surgical treatment at the proper time,the outcome of the patient was satisfying.
8.Exploring of the Mechanism of Rib Fracture Caused by Landing on Different Parts of the Trunk after Falls from Height Using Finite Element Method.
Wen Hu HU ; Yu SHAO ; Zheng Dong LI ; Dong Hua ZOU ; Jian Hua ZHANG ; Yi Jiu CHEN ; Hui Jun WANG
Journal of Forensic Medicine 2020;36(2):181-186
Objective To study the mechanism of rib fracture caused by landing on different parts of the trunk using finite element method, and to provide some new techniques and new ideas for the reconstruction of the whole process of falls from height. Methods The finite element method was used to study the rib fracture of human security model THUMS4.0 caused by landing on different parts of the trunk. Then the model was compared with actual cases and the mechanism of rib fracture caused by falls from height was analyzed from a biomechanical point of view. Results There were some differences in the stress and strain distribution as well as the rib fracture sites when different parts touched the ground. Ribs on both sides of the body were fractured when the front of the trunk touched the ground, and the fractures were mainly located in the junction of the ribs and costal cartilage and the midaxillary line area. When the right anterior part of the trunk touched the ground, rib fracture occurred first on the side that touched the ground, and rib fractures were mainly located in the area from the right midaxillary line to the posterior axillary line, and junction of ribs on both sides and costal cartilage. When the back of the trunk touched the ground, the fracture sites were mainly located on the back of the ribs on both sides. When the right posterior part of the trunk touched the ground, multiple rib fractures were likely to occur in the parts that touched the ground. The plastic strains were mainly concentrated at the fracture sites, while the von Mises stresses were not only concentrated at the fracture sites, but also at other sites. Conclusion There are some differences in rib fracture location sites and injury mechanisms when different parts of the trunk touch the ground.
Accidental Falls
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Humans
;
Rib Fractures/etiology*
;
Ribs
;
Torso
9.Evaluation of 3D Measuring Methods for Body Surface Damage and Scars.
Jin Ming WANG ; Jing Ya MI ; Wen Hu HU ; Zheng Dong LI ; Dong Hua ZOU ; Yi Jiu CHEN
Journal of Forensic Medicine 2020;36(2):204-209
Objective To assess the accuracy and reliability of the two 3D measuring methods, structured-light scanning and single-camera photogrammetry in forensic body surface damage and scar measurement. Methods The measuring results of 86 injuries by the ruler method, structured-light scanning and single-camera photogrammetry were compared and evaluated. The area measuring results of 13 simulated scars by the structured-light scanning, single-camera photogrammetry, Photoshop lasso pixel method and PDF reading software were compared and evaluated. The time consumed was recorded. The known specification information of the stickers was used as the standard value to compare the measuring accuracy of the ruler method, structural-light scanning and single-camera photogrammetry, and to calculate the root mean square error (RMSE). The consistency evaluation of intraclass correlation coefficient (ICC) for the repeatability of 3 measuring results obtained by different operators and the same operator. Results The differences in results of the two 3D measuring methods and the ruler method had no statistical significance; the differences between measuring results made by the structured-light scanning, single-camera photogrammetry and PDF reading software and that of the Photoshop lasso pixel method had no statistical significance. The post-processing of the single-camera photogrammetry consumed more time than that of other methods. When the long-distance group (10-40 cm) was measured, the results obtained by the ruler method were shorter than the standard value. The RMSE value results were structured-light scanning < single-camera photogrammetry < ruler method. The ICC value intragroup and intergroup were greater than 0.99. Conclusion Both structured-light scanning and single-camera photogrammetry can be applied in recording and measuring forensic body surface damage. The former has better performance in measurement accuracy and stability, while the latter has better color performance but longer post-processing time.
Cicatrix
;
Humans
;
Imaging, Three-Dimensional
;
Photogrammetry
;
Reproducibility of Results
;
Software
10.Analysis of Influencing Factors of Single Camera Photogrammetry in Forensic Three-Dimensional Reconstruction.
Dong Hua ZOU ; Jin Ming WANG ; Yi Jiu CHEN ; Zheng Dong LI ; Jia Wen WANG ; Zhi Qiang QIN ; Jiang HUANG
Journal of Forensic Medicine 2020;36(5):666-671
Objective To evaluate the influence of factors such as the selection of equipment, focal length and the selection of reconstruction quality in the reconstruction software on the reconstruction results of single camera photogrammetry and provide reference for the forensic application of single camera photogrammetry. Methods The 19 skulls were measured by traditional measurement method and single camera photogrammetry. The differences between the two measurement methods and within the group with same equipment but different focal length were analyzed. One skull and one corpse were selected as the research objects. According to the reconstruction quality selection conditions in the photogrammetric software, the experimental group was divided into five grades. The model reconstructed by optical scanner was defined as reference model, while the model reconstructed by single camera photogrammetry was defined as test model. The test model was aligned with the reference model, 3D deviation analysis was carried out and the mean error and root mean square (RMS) values were calculated. Results The differences between EOS 7D zoom group and traditional measurement, and within the group with same equipment had statistical significance (P<0.05). The mean error value and minimum RMS value of the skull reconstructed by single camera photogrammetry and the three-dimensional model of the corpse existed in the medium quality group, and the trend was basically the same. Conclusion The equipment and focal length has no obvious influence on the results of single camera photogrammetry. Lower reconstruction quality can easily cause distortion, while higher reconstruction quality can easily generate noise, so medium quality is preferred.
Forensic Medicine
;
Imaging, Three-Dimensional
;
Photogrammetry
;
Skull/diagnostic imaging*
;
Software

Result Analysis
Print
Save
E-mail