1.Renal sympathetic nerve ablation treatment for hypertension and its research progress
Chinese Journal of cardiovascular Rehabilitation Medicine 2014;23(2):218-220
Excessive activation of renal sympathetic nerves may be a key factor for occurrence and maintenance of hypertension.Renal sympathetic nerve ablation is a selective sympathetic denervation therapy,Which provides neW route for antihypertensive treatment.This article made an overvieW on further expansion of safety,effectiveness and indications of renal sympathetic nerve ablation treatment for hypertension.
2.Risk Factors and Hygiene Hypothesis of Inflammatory Bowel Disease
Chinese Journal of Gastroenterology 2014;(8):496-499
Till now,the etiology of inflammatory bowel disease( IBD)is still not very clear. Some genetic risk loci have been identified that predispose people to IBD,however,they increase the risk of IBD by only a small magnitude. Therefore,environmental risk factors have been the focus of recent researches. This article reviewed the association of environmental factors( hygiene and dietary factors etc. ),especially childhood hygiene with IBD,and concluded that rural environment,higher number of siblings and having pets decreased the risk of IBD,while urban environment and small household size/sibship were risk factors for IBD. Currently,population-based study focusing on hygiene and IBD is deficient domestically,further epidemiological surveys are warranted to confirm their associations.
3.Stability of femoral prosthesis after total hip replacement
Chinese Journal of Tissue Engineering Research 2015;(39):6281-6285
BACKGROUND:There are many experimental studies about compression mechanics of femur after hip replacement at home and aboard. Therefore, it is very important to study the torque, torsion angle, load-displacement relationship of femur after hip replacement. Comparing and analyzing the properties of compression and torsional mechanics of traditional-type prosthesis and anatomical-type prosthesis is of important significance for studying hip replacement and the stability of artificial prosthesis.
OBJECTIVE:To compare and analyze the stability of traditional-type prosthesis and anatomical-type prosthesis by stimulating femoral axial compression and torsion tests after hip replacement, so as to provide biomechanical parameters for clinic practice.
METHODS: Twelve specimens of left- and/or right-side femur were selected. The femoral necks of 6 left-side femur specimens were retained as the anatomical-type titanium artificial joint prosthesis group, and the femoral necks of the 6 right-side femur specimens were removed as the traditional-type cobalt-chromium-molybdenum artificial joint prosthesis group. The femur specimens in these two groups were respectively placed onto the electronic universal testing machine workbench and were imposed compression stress at the experimental velocity of 5 mm/min. The corresponding displacement values were read under the force of 20, 40, 60, 80 and 100 N. And then, both ends of the femur specimens from these two groups were placed within the chuck of torsion testing machine, and were imposed torque at the experimental velocity of 1(°)/s. The corresponding torsion angle values were read under the torque force of 5, 10, 15 and 20 N?m.
RESULTS AND CONCLUSION: Under the external force of 100 N, the displacement was (2.03±0.06) mm in the traditional-type prosthesis group, and (1.83±0.05) mm in the anatomical-type prosthesis group. Under the torque force of 20 N?m, the torsion angle values of traditional-type prosthesis was (21.7±0.7)°, and that of anatomical-type prosthesis was (13.2±0.4)°. The displacement under the external force of 100 N and the torsion angle values under the torque force of 20 N?m in the anatomical-type prosthesis group were al significantly less than those in the traditional-type prosthesis group (P < 0.05). These results suggest that traditional-type and anatomical-type prostheses have different compression and torsion mechanical properties. The anatomical-type femur prosthesis has a better stability than traditional-type femur prosthesis.
4.Evaluation of Tubal Patency with Transvaginal Three-dimensional Hysterosalpingo-contrast Sonography.
Qi CHENG ; Sha-sha WANG ; Xian-sheng ZHU ; Fan LI
Chinese Medical Sciences Journal 2015;30(2):70-75
OBJECTIVETo investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy) in assessing tubal patency with chromolaporoscopy.
METHODSA total of 157 infertile women underwent 3D-HyCoSy to evaluate tubal patency. Among these patients, 39 patients were also examined by chromolaporoscopy. The concordance of the two clinical assessment methods was analyzed by the Kappa coefficient test.
RESULTSAmong the 306 oviducts examined by 3D-HyCoSy, 99 (32.4%) were patent, 126 (41.2%) partially obstructed, and 81 (26.5%) completely obstructed. Diagnostic results with 3D-HyCoSy were not statistically different from those obtained in the 39 women (78 oviducts) who also underwent chromolaporoscopy, and the two methods showed a high concordance (k=0.747, P=0.000). The 3D-HyCoSy procedure had a sensitivity of 84.8% (28/33), a specificity of 96.2% (25/26), and positive and negative predictive values of 93.3% (28/30) and 86.2% (25/29) respectively.
CONCLUSIONTransvaginal 3D-HyCoSy can accurately reveal the spatial path and morphology of the oviduct and is a safe and effective method to evaluate tubal patency.
Contrast Media ; Fallopian Tube Patency Tests ; methods ; Fallopian Tubes ; diagnostic imaging ; Female ; Humans ; Hysterosalpingography ; Imaging, Three-Dimensional ; Infertility, Female ; diagnostic imaging ; Laparoscopy ; Ultrasonography
6.Clinical Observation of Tegafur Gimeracil Oteracil Potassium Combined with 3D-CRT and Microwave Hy-perthermia in the Treatment of Elderly Patients with Local Advance Esophageal Cancer
Sha SHA ; Mingchang HUO ; Maoyu WANG ; Maojiang LI
China Pharmacy 2016;27(26):3702-3704
OBJECTIVE:To observe clinical efficacy and safety of tegafur gimeracil oteracil potassium combined with 3D-CRT and microwave hyperthermia in the treatment of elderly patients with local advance esophageal cancer. METHODS:48 cases of local advance esophageal cancer were divided into group A,B and C according to random number table method,with 16 cases in each group according to random number table method. Group A was given 3D-CRT with total dose of 60-66 Gy totnlly for 6-7 weeks;group B was additionally given tegafur gimeracil oteracil potassium 60 mg/(m2·d),bid,on the basis of group A 3 weeks for a course of treatment,until the end of radvotherapy;group C was additionally given thermotherapy on the basis of group B 3 weeks for a course of treatment,until the end of radvotherapy. Clinical efficacy,1-year survival rate,dysphagia,weight and KPS score were compared among 3 groups,and the occurrence of toxic reactions(radioactive esophagitis,radioactive pneumonia, bone marrow suppression and gastrointestinal reaction) were observed in 3 groups. RESULTS:Total effective rate,1-year survival rate and the remission rate of dysphagia of group C were 93.75%,87.50% and 93.75%,which were significantly higher than those of group A(50.00%,50.00% and 56.25%)and B(68.75%,68.75% and 68.75%),with statistical significance(P<0.05). There was no statistical significance in the rate of weight gain and KPS score gain among 3 groups(P>0.05). The incidence of radioactive esophagitis and radioactive pneumonia in group C were significantly lower than in group A and B,with statistical significance(P<0.05);there was no statistical significance in the incidence of gastrointestinal reaction and bone marrow suppression among 3 groups (P>0.05). CONCLUSIONS:Tegafur gimeracil oteracil potassium combined with 3D-CRT and microwave hyperthermia in the treat-ment of elderly patients with local advance esophageal cancer further improves clinical efficacy and survival rate,but shows low inci-dence of toxic reaction.
7.The effects of graphene quantum dots on hematopoietic system in rats.
Chinese Journal of Applied Physiology 2016;32(1):60-64
OBJECTIVETo study the effects of graphene quantum dots (GQDs) on hematopoietic system in rats.
METHODSThirty male SD rats were randomly divided into three groups (n = 10): control group, high dose group (10 mg/kg · d), low dose group (5 mg/kg · d), The rats in experimental group were intravenous injected with GQDs for 28 days and those in control group were injected with normal saline at the same volume. Routine blood and the function of liver and kidney were detected by instrument analysis. The cycle and apoptosis of bone marrow mononuclear cells (BMCs) were detected by FCM. The other three only healthy male SD rat bone marrow mononuclear cells (BMCs) were cultured by joining GQDs for 24 h, 48 h,72 h in vitro, the proliferation was assayed by CCK-8, the content of granulocyte macrophage colony stimulating factor (GM-CSF) from cultural supernatants were detected by ELISA.
RESULTSThe amount of red blood cell and concentration of hemoglobin from experimental group were increased significantly compared with those of control groups (P < 0.05), the concentration of triglyceride and high density lipoprotein were decreased. DNA synthesis period was prolonged (P < 0.01), there was no significant difference in apoptosis. BMCs were promoted proliferation clearly after using GQDs for 72 h (P < 0.05). The content of GM-CSF was increased (P < 0.01) .
CONCLUSIONGQDs may promote hematopoietic function in rats.
Animals ; Apoptosis ; Bone Marrow Cells ; drug effects ; Granulocyte-Macrophage Colony-Stimulating Factor ; metabolism ; Graphite ; pharmacology ; Hematopoiesis ; drug effects ; Male ; Quantum Dots ; chemistry ; Rats ; Rats, Sprague-Dawley
8.Isolation and purification of human cytotrophoblasts and placental mesenchymal stem cells
Wenqiong SHA ; Zineng WANG ; Dongju WANG
Chinese Journal of Tissue Engineering Research 2010;14(10):1833-1837
BACKGROUND:Cytotrophoblasts in placental cell components plays an important role in fetal immunological tolerance.Placental mesenchymal stem cells(pMSCs)have potential of multiple differentiation and inhibition of lymphocyte proliferation.However,conventional methods cannot acquire a large amount of purified human cytotrophoblasts or pMSCs.OBJECTIVE:To establish a method to obtain large placenta tissue,and harvest plenty of cytotrophoblasts and pMSCs with high purity and activity.METHODS:Human placenta tissues were dissected,minced,and dissociated in trypsin and DNAse I.The dissociation was performed in three stages of incubation at 180 r/min for 20 minutes at 37 ℃ The digesting suspension was filtered using a 200 mesh strainer before separated by Percoll gradients.The cytotrophoblast cells and pMSCs fractions were collected respectively.Fibroblasts of cytotrophoblast cells fraction were removed by differential adhesion.The pMSCs were seeds on 75-cm2 flask directly for culture.The dissociation of placenta tissue was observed.The number of harvesting cytotrophoblasts was quantified and Cytokeratin 7 expression was tested.The pMSCs primary culture time,cell passage,induced osteoblast differentiation were observed.The cell surface makers were also detected.RESULTS AND CONCLUSION:After digesting in trypsin and DNAse I,there was only little residue left.(5.48±1,98)×10~8 cytotrophoblasts were obtained after differential adhesion.(90±4.36)% of these cells were positive for Cytokeratin 7.At 19-21 days after pMSCs reached approximately 90% confluency,the cell number was(1.96±0.24)×10~6.The subcultre cells could be passaged again in 4 or 5 days.Flow cytometric analysis of pMSCs showed that the cells expressed CD29,CD44 and HLA-ABC intensively and were negative for CD34,CD45,CD14 and HLA-DR.pMSCs differentiated into osteoblast-like cells after induction,which stained bright salmon pink by Alizarin Red.Dissociating the placenta tissue in trypsin and DNAse I in combination with discontinuous Percoll gradient separation obtained a large number of cytotrophoblasts and pMSCs recovered from placenta tissue,with high purity and activity.
9.Acoustic radiation force impulse imaging in differential diagnosis of small solid thyroid nodules coexisting with Hashimoto's thyroiditis
Yumeng SHA ; Xintian WANG ; Rong WANG
Chinese Journal of Interventional Imaging and Therapy 2017;14(8):504-508
Objective To investigate the application value of acoustic radiation force impulse imaging (ARFI) in differential diagnosis of small solid thyroid nodules coexisting with Hashimoto's thyroiditis (HT).Methods A total of 136 patients with 155 small solid nodules (≤1 cm in diameter) confirmed by pathology were included.The small solid nodules were divided into HT group and normal group.All patients underwent virtual tissue imaging (VTI) and virtual touch tissue quantification (VTQ).The stiffness of small solid thyroid nodules in two groups was respectively scored based on VTI images,and the area ratios of nodules in VTI images to gray scale images were calculated.Taking pathological diagnosis as the gold standard,the ROC curve were performed to explore the optimal points and efficacy of area ratio and shear wave velocity (SWV) in the diagnosis of malignant nodules in two groups respectively.Results Regarding VTI score≥4 as the diagnostic standard of malignant nodules,the sensitivity of HT group and normal group in diagnosis of malignant nodules had significant difference (64.29%[27/42] vs 81.69%[58/71],P<0.05).In two groups,the area ratio and SWV of malignant nodules were significantly higher than those of benign nodules (all P<0.05).The area ratio and SWV of thyroid benign nodules and malignant nodules had no significantly difference between two groups (all P>0.05).Taking 1.41 as the cutoff point of area ratio,the sensitivity and specificity in diagnosis of malignant nodules in HT group were 85.7% and 88.9%.Taking 2.87 m/s as the cutoff point of SWV,sensitivity and specificity in diagnosis of malignant nodules in HT group were 85.7% and 94.4%.Taking 1.40 as the cutoff point of area ratio,the sensitivity and specificity in diagnosis of malignant nodules in normal group were 91.5% and 95.8%.Taking 2.67 m/s as the cutoff point of SWV,the sensitivity and specificity in diagnosis of malignant nodules in normal group were 88.7% and 95.8%.Conclusion ARFI technology can evalu-ate the hardness of the small solid thyroid nodules through the intuitive VTI images and objective SWV values in HT,which is helpful in diagnosis of malignant nodules in HT backgroud.
10.On the Status of the Domestic Mobile Medical Software Supervision.
Shuai WANG ; Chunmiao DU ; Xianzheng SHA
Chinese Journal of Medical Instrumentation 2015;39(5):353-355
With the widespread use of smart phones, mobile medical class of applications use more widely. The regulation for medical applications is in the offing in domestic. How to effectively regulate such software to control its risks for patients is needed to solve. In this paper, the status of such simple software monitoring in domestic and abroad is analyzed, some problems of domestic mobile medical applications are summarized and some recommendations are proposed for the relevant departments.
Mobile Applications
;
Smartphone