1.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
3.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
4.Development and application of a rapid scheme for detection of respiratory virus nucleic acid.
Yuanyuan HUANG ; Yu WANG ; Chengxing ZHOU ; Zhichao ZHOU ; Bingliang ZHOU ; Wenkuan LIU ; Rong ZHOU ; Hong CAO
Chinese Journal of Biotechnology 2023;39(9):3838-3848
This study aimed to develop a portable, accurate and easy-to-operate scheme for rapid detection of respiratory virus nucleic acid. Quantitative real-time polymerase chain reaction (qRT-PCR) was used to verify the effect of extraction-free respiratory virus treatment reagent (RTU) on viral nucleic acid treatment and the effect of ultra-fast fluorescence quantitative PCR instrument (FQ-8A) on nucleic acid amplification, respectively. RTU and FQ-8A were combined to develop a rapid detection scheme for respiratory virus nucleic acid, and the positive detection rate was judged by Ct value using a fluorescence quantitative PCR instrument, and the accuracy of the scheme in clinical samples detection was investigated. The results showed that RTU had comparable sensitivity to the automatic nucleic acid extraction instrument, its extraction efficiency was comparable to the other 3 extraction methods when extracting samples of different virus types, but the extraction time of RTU was less than 5 min. FQ-8A had good consistency in detection respiratory syncytial virus (RSV) and adenovirus (ADV) compared with the control instrument ABI-7500, with kappa coefficients of 0.938 (P < 0.001) and 0.887 (P < 0.001), respectively, but the amplification time was only about 0.5 h. The RTU and FQ-8A combined rapid detection scheme had a highly consistent detection rate with the conventional detection scheme, with a sensitivity of 91.70% and specificity of 100%, and a kappa coefficient was 0.944 (P < 0.001). In conclusion, by combining RTU with FQ-8A, a rapid respiratory virus nucleic acid detection scheme was developed, the whole process could be completed in 35 min. The scheme is accurate and easy-to-operate, and can provide important support for the rapid diagnosis and treatment of respiratory virus.
Humans
;
Respiratory Syncytial Virus Infections/diagnosis*
;
Respiratory Syncytial Virus, Human/genetics*
;
Nucleic Acid Amplification Techniques
;
Real-Time Polymerase Chain Reaction
;
Adenoviridae
;
Sensitivity and Specificity
5.Comparison on Performance of Quantitative Ultrasound and Dual-Energy X-ray Absorptiometry in Evaluating Bone Health of Adults Aged 18-40 Years.
Yu-Xian KUANG ; Hong CHENG ; Yi-Ying ZHENG ; Wei-Ye CHEN ; Zhen-Xin MA ; Gao-Yong ZOU ; Ding ZENG ; Jie MI ; Li LIU
Acta Academiae Medicinae Sinicae 2023;45(5):737-742
Objective To compare the consistency of quantitative ultrasound(QUS)and dual-energy X-ray absorptiometry(DXA)in measuring bone mineral density(BMD)of adults aged 18-40 years in Guangzhou and evaluate the diagnostic value of QUS for identifying low bone mass.Methods DXA was employed to measure the BMD and QUS to measure the speed of sound(SOS)in 731 participants.The Bland-Altman analysis was performed to evaluate the consistency of Z scores between SOS and BMD.With the BMD Z ≤-2.00 as the diagnostic criterion for low bone mass,the receiver operating characteristics curve of QUS was established,and the area under the curve(AUC)and the sensitivity,specificity,and correct diagnostic index for the optimal cut-off of SOS Z score were calculated.Results The results of Bland-Altman analysis showed that the mean differences in the Z scores of SOS and BMD in males and females were 1.27(-0.94 to 3.47)and 0.93(-1.33 to 3.18),respectively.The AUC of SOS Z score in the diagnosis of low bone mass in males and females was 0.734(95%CI=0.380-0.788)and 0.679(95%CI=0.625-0.732),respectively.In males,the optimal cut-off of SOS Z score for low bone mass was -0.35,with the sensitivity,specificity,and correct diagnostic index of 64.1%,68.6%,and 0.327,respectively.In females,the optimal cut-off value of SOS Z scores for low bone mass was -1.14,with the sensitivity,specificity,and correct index of 73.9%,54.8%,and 0.285,respectively.Conclusion QUS and DXA show poor consistency in the diagnosis of BMD in the adults aged 18-40 years in Guangzhou,while QUS demonstrates an acceptable value in identifying low bone mass.
Male
;
Female
;
Adult
;
Humans
;
Absorptiometry, Photon/methods*
;
Bone Density
;
Ultrasonography
;
Bone and Bones
;
ROC Curve
;
Sensitivity and Specificity
6.A study on the application of cross-frequency coupling characteristics of neural oscillation in the diagnosis of mild cognitive impairment.
Xin LI ; Kai WANG ; Jun JING ; Liyong YIN ; Ying ZHANG ; Ping XIE
Journal of Biomedical Engineering 2023;40(5):843-851
In order to fully explore the neural oscillatory coupling characteristics of patients with mild cognitive impairment (MCI), this paper analyzed and compared the strength of the coupling characteristics for 28 MCI patients and 21 normal subjects under six different-frequency combinations. The results showed that the difference in the global phase synchronization index of cross-frequency coupling under δ-θ rhythm combination was statistically significant in the MCI group compared with the normal control group ( P = 0.025, d = 0.398). To further validate this coupling feature, this paper proposed an optimized convolutional neural network model that incorporated a time-frequency data enhancement module and batch normalization layers to prevent overfitting while enhancing the robustness of the model. Based on this optimized model, with the phase locking value matrix of δ-θ rhythm combination as the single input feature, the diagnostic accuracy of MCI patients was (95.49 ± 4.15)%, sensitivity and specificity were (93.71 ± 7.21)% and (97.50 ± 5.34)%, respectively. The results showed that the characteristics of the phase locking value matrix under the combination of δ-θ rhythms can adequately reflect the cognitive status of MCI patients, which is helpful to assist the diagnosis of MCI.
Humans
;
Electroencephalography/methods*
;
Cognitive Dysfunction/diagnosis*
;
Neural Networks, Computer
;
Sensitivity and Specificity
7.Value of contrast-enhanced percutaneous ultrasound in the diagnosis of rotator cuff tear subtype.
Bi-Li LIU ; Yue SHAN ; Qi ZHONG ; Dan GE ; Yan-Ping LI ; Juan LYU ; Shu-Zhi GAN
China Journal of Orthopaedics and Traumatology 2023;36(10):974-981
OBJECTIVE:
To explore characteristics of contrast-enhanced ultrasound (CEUS) images features and diagnostic value of rotator cuff tear subtypes.
METHODS:
From January 2019 to March 2022, percutaneous ultrasound-guided subacromial bursography (PUSB) with persutaneous ultrasound-guide tendon lesionography (PUTL) was performed on 114 patients with suspected rotator cuff injury were evaluated, including 54 males and 60 females ranged in age from 35 to 75 years old with an average of (58.8±8.7 ) years old;76 patients on the right side and 38 patients on the left side;the course of disease ranged from 0.13 to 111 months with an average of (10.2±9.8) months. GE LOGIQ E9 color doppler ultrasound diagnostic high frequency(6 to 12 MHz) was used to CEUS Using arthroscopy as gold standard, receiver operating characteristic (ROC) curve was used to evaluate diagnostic efficacy of US, MRI and CEUS for rotator cuff injury, also sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.
RESULTS:
The sensitivity of US in diagnosing full-thickness tears was 72.1%, specificity was 93.0%, and accuracy was 85.1%. The sensitivity, specificity and accuracy of MRI diagnosis of full-thickness tear were 90.9%, 92.6% and 92.1% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of full-thickness tear were 100%. The sensitivity, specificity and accuracy of US in the diagnosis of partial tear were 85.7%, 77.2% and 79.8% respectively. The sensitivity, specificity and accuracy of MRI diagnosis of partial tear were 83.7%, 81.7% and 82.5% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of partial tear were 95.7%, 92.6% and 93.9% respectively. There were significant differences in diagnosis results of US, MRI and CEUS for rotator cuff bursa tear (P<0.001). Kapp test showed good consistency between CEUS and arthroscopy in diagnosing rotator cuff tear subtypes (full-thickness and partial tears).
CONCLUSION
Using PUSB/PUTL to observe distribution of contrast media in bursa, tendon and joint cavity to evaluate the type of rotator cuff tear, its diagnostic performance is significantly better than US and MRI. Therefore, percutaneous contrast-enhanced ultrasound can be a reliable method for diagnosing subtypes of rotator cuff tears.
Male
;
Female
;
Humans
;
Infant, Newborn
;
Infant
;
Child, Preschool
;
Child
;
Rotator Cuff Injuries/diagnostic imaging*
;
Rotator Cuff/diagnostic imaging*
;
Sensitivity and Specificity
;
Ultrasonography
;
Magnetic Resonance Imaging/methods*
;
Rupture
;
Arthroscopy
8.Application of metagenomic next-generation sequencing of bronchoalveolar lavage fluid in the diagnosis and treatment of refractory pneumonia in children.
Rong-Guang FENG ; Li-Yan ZHOU ; Rui DOU ; Xue-Yuan ZHOU ; Li-Rong WANG ; Li-Hong HAN ; Yu-Min WANG
Chinese Journal of Contemporary Pediatrics 2023;25(12):1253-1258
OBJECTIVES:
To investigate the clinical application of metagenomic next-generation sequencing (mNGS) of bronchoalveolar lavage fluid (BALF) in the etiological diagnosis and treatment of refractory pneumonia (RTP) in children.
METHODS:
A retrospective analysis was performed on 160 children with RTP who were admitted to the Department of Pediatric Internal Medicine, Maternal and Child Health Hospital of Inner Mongolia Autonomous Region, from January 2020 to March 2023. According to whether mNGS was performed, they were divided into two groups: mNGS (n=80) and traditional testing (n=80). All children received the tests of inflammatory markers and pathogen tests after admission. Traditional pathogenicity tests included microbial culture (sputum specimen collected by suction tube), nucleic acid detection of respiratory pathogens, and serological test (mycoplasma, tuberculosis, and fungi). For the mNGS group, BALF specimens were collected after bronchoscopy and were sent to the laboratory for mNGS and microbial culture. The two groups were analyzed and compared in terms of the detection of pathogens and treatment.
RESULTS:
Compared with the traditional testing group, the mNGS group had a significantly higher detection rate of pathogens (92% vs 58%, P<0.05), with more types of pathogens and a higher diagnostic rate of mixed infections. Compared with the traditional testing group, the mNGS group had a significantly higher treatment response rate and a significantly lower incidence rate of complications during hospitalization (P<0.05). Treatment was adjusted for 68 children in the mNGS group according to the results of mNGS, with a treatment response rate of 96% (65/68) after adjustment.
CONCLUSIONS
Compared with traditional pathogen tests, BALF mNGS can significantly improve the detection rate of pathogens and find some rare pathogens. In clinical practice, when encountering bottlenecks during the diagnosis and treatment of children with RTP, it is advisable to promptly perform the mNGS to identify the pathogens.
Humans
;
Child
;
Bronchoalveolar Lavage Fluid
;
Retrospective Studies
;
Pneumonia/therapy*
;
High-Throughput Nucleotide Sequencing
;
Bronchoscopy
;
Sensitivity and Specificity
9.The performance of digital chest radiographs in the detection and diagnosis of pulmonary nodules and the consistency among readers.
Min LIANG ; Shi Jun ZHAO ; Li Na ZHOU ; Xiao Juan XU ; Ya Wen WANG ; Lin NIU ; Hui Hui WANG ; Wei TANG ; Ning WU
Chinese Journal of Oncology 2023;45(3):265-272
Objective: To investigate the detection and diagnostic efficacy of chest radiographs for ≤30 mm pulmonary nodules and the factors affecting them, and to compare the level of consistency among readers. Methods: A total of 43 patients with asymptomatic pulmonary nodules who consulted in Cancer Hospital, Chinese Academy of Medical Sciences from 2012 to 2014 and had chest CT and X-ray chest radiographs during the same period were retrospectively selected, and one nodule ≤30 mm was visible on chest CT images in the whole group (total 43 nodules in the whole group). One senior radiologist with more than 20 years of experience in imaging diagnosis reviewed CT images and recording the size, morphology, location, and density of nodules was selected retrospectively. Six radiologists with different levels of experience (2 residents, 2 attending physicians and 2 associate chief physicians independently reviewed the chest images and recorded the time of review, nodule detection, and diagnostic opinion. The CT imaging characteristics of detected and undetected nodules on X images were compared, and the factors affecting the detection of nodules on X-ray images were analyzed. Detection sensitivity and diagnosis accuracy rate of 6 radiologists were calculated, and the level of consistency among them was compared to analyze the influence of radiologists' seniority and reading time on the diagnosis results. Results: The number of nodules detected by all 6 radiologists was 17, with a sensitivity of detection of 39.5%(17/43). The number of nodules detected by ≥5, ≥4, ≥3, ≥2, and ≥1 physicians was 20, 21, 23, 25, and 28 nodules, respectively, with detection sensitivities of 46.5%, 48.8%, 53.5%, 58.1%, and 65.1%, respectively. Reasons for false-negative result of detection on X-ray images included the size, location, density, and morphology of the nodule. The sensitivity of detecting ≤30 mm, ≤20 mm, ≤15 mm, and ≤10 mm nodules was 46.5%-58.1%, 45.9%-54.1%, 36.0%-44.0%, and 36.4% for the 6 radiologists, respectively; the diagnosis accuracy rate was 19.0%-85.0%, 16.7%-6.5%, 18.2%-80.0%, and 0%-75.0%, respectively. The consistency of nodule detection among 6 doctors was good (Kappa value: 0.629-0.907) and the consistency of diagnostic results among them was moderate or poor (Kappa value: 0.350-0.653). The higher the radiologist's seniority, the shorter the time required to read the images. The reading time and the seniority of the radiologists had no significant influence on the detection and diagnosis results (P>0.05). Conclusions: The ability of radiographs to detect lung nodules ≤30 mm is limited, and the ability to determine the nature of the nodules is not sufficient, and the increase in reading time and seniority of the radiologists will not improve the diagnostic accuracy. X-ray film exam alone is not suitable for lung cancer diagnosis.
Humans
;
Retrospective Studies
;
Solitary Pulmonary Nodule/diagnostic imaging*
;
Radiography
;
Multiple Pulmonary Nodules/diagnostic imaging*
;
Tomography, X-Ray Computed/methods*
;
Lung Neoplasms/diagnostic imaging*
;
Sensitivity and Specificity
;
Radiographic Image Interpretation, Computer-Assisted/methods*
10.Implementation and quality control of human immunodeficiency virus laboratory diagnosis strategy.
Yuan Fang WANG ; Dong Dong LI ; Yi XIE
Chinese Journal of Preventive Medicine 2023;57(1):1-7
The laboratory diagnostic strategy for human immunodeficiency virus (HIV) is a process to accurately detect HIV patients through a combination of available HIV tests. Laboratory tests for HIV infection are mainly serological antibody and antigen testing and HIV RNA testing. With the update of testing reagents, the sensitivity and specificity have improved substantially and the window period of detection has shortened, but there is a risk of false positives. Various guidelines have recommended different diagnostic strategies for different target populations and different prevalence regions to guide patients to confirm the diagnosis and receive standardized antiretroviral therapy as early as possible. How to refer to the diagnostic strategies, reduce false positives and shorten the window period while increasing the detection rate is an urgent issue for laboratories to address. This article describes the characteristics and advantages and disadvantages of testing methods related to HIV infection from the perspective of laboratory diagnostic strategies, as well as the impact of the development of treatments on diagnostic strategies, in order to provide theoretical support for the practical application of HIV diagnostic strategies.
Humans
;
HIV
;
HIV Infections/diagnosis*
;
Sensitivity and Specificity
;
Clinical Laboratory Techniques/methods*
;
Quality Control


Result Analysis
Print
Save
E-mail