1.Alternative self-retaining retractors for head and neck surgery
Samantha S. Castaneda ; Roselle C. Bargo
Philippine Journal of Otolaryngology Head and Neck Surgery 2009;24(2):36-37
Objective:To design affordable, easy-to-use self-retaining retractors that can provide adequate exposure of the operative area in head and neck surgery Methods: Design: Surgical Instrumentation Setting: Tertiary government hospital Subjects: One Results: Self-retaining retractors were designed and fabricated from stainless steel with tissue prongs on one end and a loop for rubber-band attachment to surgical drapes via a towel clip on the other end. Varying prong lengths were devised for different depths of required retraction. Traction tension could be adjusted by varying rubber-band attachment distance. The retractors were tested on a patient undergoing open reduction and internal fixation for a mandibular fractureand evaluated according to ease of application, adequacy of exposure and tissue trauma. Conclusion: The self-retaining retractors may be affordable alternatives to commercially-available self-retaining retractors. They are easily applied with adjustable tension and depth of retraction that can provide adequate exposure with minimal tissue trauma.
INSTRUMENTATION
2.Development of slit-lamp microscope and its applications in optics.
Chinese Journal of Medical Instrumentation 2013;37(6):437-440
This paper mainly introduces the origin and development of the slit-lamp microscope, the basic structure, working principle and test methods, focuses on diffuse illumination, direct focal illumination, indirect illumination, retro illumination, zone of specular reflection and slit-lamp filter used in the optical inspection, to provide the reference for clinical general optometry practitioners and using slit-lamp microscope widely and standardized.
Lighting
;
instrumentation
;
Ophthalmology
;
instrumentation
3.Development of an embedded mobile terminal for real-time remote monitoring of out-of-hospital cardiac patients.
Zhi-min XU ; Zu-Xiang FANG ; Da-Kun LAI ; Hai-Lang SONG
Chinese Journal of Medical Instrumentation 2007;31(3):182-191
A kind of real-time remote monitoring embedded terminal which is combined with mobile communication technology and GPS localization technology, has been developed. The results of preliminary experiments show that the terminal can transmit ECG signals and localization information in real time and continuously, supply a real-time monitoring of out-of-hospital cardiac patients and trace the patients.
Electrocardiography, Ambulatory
;
instrumentation
;
Telemedicine
;
instrumentation
;
Telemetry
;
instrumentation
4.Reliability of OneCeph Cephalometric Analysis Application on the Devices with Different Screen Size
Archives of Orofacial Sciences 2022;17(1):137-150
ABSTRACT
This study aimed to assess the reliability of the OneCeph application according to personal
computer (PC), tablet and smartphone screen size in comparison with Dolphin software on
PC as a gold standard. Cephalometric landmarks were identified on 100 digital radiographs.
Twenty-four cephalometric measurements were made with Dolphin software as a gold standard
comparing with OneCeph application on smartphone (OS), OneCeph on PC (OP) and
OneCeph on tablet (OT). All measurements were repeated after four weeks for intra-examiner
reliability with intraclass correlation coefficients (ICC). One-way ANOVA and Kruskal Wallis
test were done for measurement comparison between methods (Dolphin, OS, OP and OT).
Results for OneCeph on smartphone and tablet, 21 measurements were comparable with
Dolphin while other three (NLA, H-angle and UL to S-plane) were not. In OneCeph on PC,
20 measurements were comparable with Dolphin while other four (NLA, H-angle, U1 to A-point
and UL to S-plane) were not. All different measurements were clinically insignificant except H-angle.
Intra-examiner reliability represented ICC above 0.9. In conclusion, OneCeph application on three
different screen size is reliable to use for cephalometric measurement. Most of the measurements are
comparable with gold standard and adequate to be utilised in clinical routine. OneCeph on smartphone
and tablet are advantageous from the portable feature over PC.
Cephalometry--instrumentation
5.Advances of cryotherapy technology.
Qing-hao KONG ; Zhong-min ZHANG
Chinese Journal of Medical Instrumentation 2007;31(1):44-47
This article introduces cryosurgery devices, cryopreservation devices, some cryogenic freezing methods in medicine and the recent progress about cryotherapy technology.
Cryopreservation
;
instrumentation
;
Cryotherapy
;
instrumentation
;
methods
6.Study and compare of the bidirectional filtering technique for anti-baseline drift.
Lingfeng KONG ; Daxue WEI ; Yunpeng LIAO
Chinese Journal of Medical Instrumentation 2010;34(4):263-265
Several digital filtering techniques for correcting baseline drift from ECG signals are presented. A bidirectional filter is introduced, which can cantain baseline drift their filtering performance and realization methods are compared.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
;
instrumentation
;
Signal Processing, Computer-Assisted
;
instrumentation
7.The development and applications of electrosurgical equipment.
Chinese Journal of Medical Instrumentation 2002;26(6):437-465
We here in the paper, not only introduce the development of electricsurgical operation equipment in our country and foreign countries but also represent the characters, principles and usages of several kinds electrosurgical equipment in foreign countries.
Argon
;
Catheter Ablation
;
instrumentation
;
Electrocoagulation
;
instrumentation
;
Electrosurgery
;
instrumentation
;
Humans
;
Ions
8.A comparative study on dual-magnetic circuit beads and scattering nephelometry coagulometers in coagulational evaluation of blood-contact medical devices.
Tun YUAN ; Jie LIANG ; Jing SAN ; Li-Ping ZHENG ; Wei-Jing ZHU
Chinese Journal of Medical Instrumentation 2008;32(1):54-57
Dual-magnetic circuit beads and scattering nephelometry dual channel semiautomatic coagulometers are used for the coagulational evaluation of the 5 blood contact medical devices which consist of metals and polymers. The partial thromboplastin time(PTT) and prothrombin time(PT) tests are made based on the GB/T 16886.4-2003 standard. The results indicate that the coefficient of variation in the two groups is in the identical order of magnitude. In the PTT tests, they give the similar evaluational results. With the smaller numerical values of the PT tests, the different coagulometers give the high consilience results. So, both of dual-magnetic circuit beads and scattering nephelometry coagulometers are acceptable in the medical devices' coagulational evaluations. But the interpretation and analysis of the results of the small numerical value tests, PT tests for example, should be noticed.
Blood Coagulation Tests
;
instrumentation
;
methods
;
Magnetics
;
instrumentation
;
Nephelometry and Turbidimetry
;
instrumentation
9.Normalize product registration standard of digital mammography system.
Yujing ZHANG ; Zhicheng LIU ; Zhiyong SUN
Chinese Journal of Medical Instrumentation 2012;36(2):125-148
This paper aims to discuss the issues needed to be considered during the process of defining the registered product standards and industry standards of digital mammographic X-ray camera system. Meanwhile, for the future reference of establishment of standards, it adds the additional technical requirements not only from the features of device's structure, but also from the risk of clinical use.
Mammography
;
instrumentation
;
standards
;
Radiographic Image Enhancement
;
instrumentation
10.Developing a high quality video transmission system based on mobile network.
Chinese Journal of Medical Instrumentation 2014;38(1):30-32
To meet the demands of high definition of video and transmission at real-time during the surgery of endoscope, this paper designs an HD mobile video transmission system. This system uses H.264/AVC to encode the original video data and transports it in the network by RTP/RTCP protocol. Meanwhile, the system implements a stable video transmission in portable terminals (such as tablet PCs, mobile phones) under the 3G mobile network. The test result verifies the strong repair ability and stability under the conditions of low bandwidth, high packet loss rate, and high delay and shows a high practical value.
Equipment Design
;
Telemedicine
;
instrumentation
;
Video Recording
;
instrumentation