1.Distribution of HPV infection in laryngopharyngeal squamous cell carcinoma and laryngeal papilloma
ying Hui HU ; kun Zhen YU ; ba Shuang HE ; xiang Qing ZHANG ; chun Shan GONG ; dong Hai ZHANG
Journal of Medical Postgraduates 2017;30(12):1264-1267
Objective Human papillomavirus (HPV) is presumed to be the cause of the development of head and neck squamous cell carcinoma.However,the current research results are not very sure.The article was designed to study the distribution of HPV infection in the tissues of laryngopharyngeal squamous cell carcinoma and laryngeal papilloma and its significance.Methods We collected samples of tissues from 67 patients who were treated in our hospital,including 41 cases of laryngeal papilloma,26 cases with laryngeal carcinoma,hypopharyngeal carcinoma,and oropharyngeal carcinoma.In the same period,20 cases of benign vocal cord polyps were treated as control group.PCR was applied in HPV typing test of fresh tumor tissues from operations,followed by the analysis on HPV infection type and distribution.Results In research group,44/67 cases was HPV-positive (65.7%),among which the HPV types of the laryngeal papilloma were HPVll (36/41) and HPV6 (4/41),and HPVI6 (6/26) in laryngeal carcinoma,hypopharyngeal carcinoma,and oropharyngeal carcinoma.While in control group,vocal cord polyps were HPV-negative without any multitype infection.Conclusion HPV16 may be a risk factor for the occurrence of laryngeal cancer and oropharyngeal cancer (non-alcoholic-induced or non-tobacco-induced cancer).HPV has high prevalence in Chinese laryngeal papilloma people,but HPV has low prevalence in Chinese laryngeal or hypopharyngeal carcinoma people.HPV testing of head and neck cancer is worth promoting.
3.Clinical analysis of arytenoid cartilage reposition with snake mouth forceps for the arytenoid cartilage dislocation.
Qing Xiang ZHANG ; Shuang Ba HE ; Zi Gang CHE ; Hui Ying HU ; Ya Qun LIU ; Yuan Yuan LU ; Zhen Kun YU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2018;32(6):404-407
OBJECTIVES:
To investigate the clinical effect of the arytenoid cartilage reposition using snake mouth reduction forceps under general anesthesia.
METHODS:
Data of twenty-six cases accepted arytenoid cartilage reposition under intravenous general anesthesia were analyzed, nineteen cases accepted laryngeal CT scan and cricoarytenoid joint reconstruction, all patients underwent endolaryngeal muscle electromyography examination. According to the position of cartilage dislocation prompted by laryngoscope and CT, the arytenoid cartilage was repositoned under the visual laryngoscope using special snake mouth reduction forceps. If bilateral arytenoid cartilage were still asymmetrically at the end of the surgery, patients needed repeated reposition 1 to 2 times 1 week after operation. The efficacy was evaluated 4 weeks later.
RESULTS:
All patients had a hoarse and breathing voice preoperative. Under laryngoscope, there were different degrees of vocal cord movement disorders accompanied by incomplete glottis closure, 22 cases happened in left side and 4 in right side. The arytenoid cartilage was dislocated anteromedially in 25 cases and posterolaterally in 1 case. CT showed that 15 cases of arytenoid cartilage were tilted anteromedially; the interval of the cricoarytenoid joint was widened. In axial CT images, there were no direct signs of the arytenoid cartilage dislocation in the 4 cases, but the abnormal position was seen in the reconstruction images. The laryngeal electromyography indicated that 7 cases were abnormal, duration of motor unit potential were visible and the raising potential were mixed. There were 4 patients with normal voice in the first day after surgery, and 19 cases underwent twice and 3 cases underwent three times surgery. Vioce became normal in 4 weeks. Swallowing pain and bucking were all disappeared. Vocal cords movement were recovered to normal level in 25 cases. In 1 case with neck strangulation, the vocal cord movement was slightly worse than health side, but significantly better than that before operation.
CONCLUSIONS
The arytenoid cartilage reposition using snake mouth reduction forceps under general anesthesia was an effective method for the treatment of the cricoary-tenoid joint dislocation.
Anesthesia, General
;
instrumentation
;
Arytenoid Cartilage
;
injuries
;
Hoarseness
;
Humans
;
Laryngoscopes
;
Mouth
;
Surgical Instruments
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve