1.On the significance of endoscopic ultrasonography before laparoscopic cholecystectomy
Erjiao XU ; Xiaoyan XIE ; Zuofeng XU
Chinese Journal of Minimally Invasive Surgery 2005;0(07):-
1.0 cm in diameter.
2.Combined detection of CA15-3,TSGF,OPN and CA125 in the diagnosis and treatment of breast cancer
Fengliang XU ; Peng WU ; Gangping WANG ; Zuofeng ZHANG ; Zhaohong SHEN
Cancer Research and Clinic 2010;22(9):615-618
Objective To explore the clinical value of combined detection of CA15-3, TSGF, OPN and CA125 in the diagnosis and treatment of breast cancer. Methods The serum specimens from 187 patients with breast cancer (cancer group) were collected, tumor markers CA15-3 and CA125 were detected with electrochemiluminescence method, TSGF was detected with chemocolorimetry, and OPN was detected with enzyme-linked immunosorbent assay. Compared with 50 cases of patients with benign breast disease (control group), The relationship between these marker and clinical stage, recurrence and metastasis of breast cancer were analyzed. Results The serum levels of CA15-3, CA125, TSGF and OPN in cancer group were significantly higher than those in control group (P <0.05). Four markers in high clinical stage(Ⅲ and Ⅳ stage)[(83.21±28.67), (89.13±32.34), (278.66±137.23) U/ml and (97.4±11.7) ng/ml, respectively] were higher than those in low stage( Ⅰ and Ⅱ stage) [(60.03±19.35), (58.21±17.56), (155.79±113.11) U/ml and (77.5±10.81) ng/ml,respectively] (P <0.05), and those in lymphnode metastasis patients and in recurrence patients were significantly higher than those in corresponding groups (P <0.05). The sensitivity and specificity of the combined detection of four tumor markers were 96.3 % (180/187) and 80.0 % (40/50), respectively. The average time of combined detection of serum tumor markers was 2 months ahead of the mammographic features in the recurrence patients with breast cancer. Conclusion The dynamic combined detection of CA15-3, TSGF, OPN and CA125 are better markers for monitoring recurrence and metastasis of breast cancer,which are benefit to early diagnosis and interference.
3.Contrast enhanced ultrasound of solid focal lesions of pancreas:comparison with contrast enhanced computed tomography
Erjiao XU ; Xiaoyan XIE ; Huixiong XU ; Ming KUANG ; Zuofeng XU ; Keguo ZHENG ; Guangjian LIU ; Mingde Lü
Chinese Journal of Ultrasonography 2008;17(9):768-772
Objective To assess the characterization and usefulness of contrast enhanced ultrasound (CEUS)to diagnose solid focal lesions of pancreas(s-FLPs)in comparison to contrast enhanced computed tomography(CECT).Methods Forty-nine s-FLPs with final diagnosis were studied with low mechanical index CEUS and CECT.The enhanced patterns and diagnostic capability of CEUS were analyzed,and these results were compared with those from CECT.Results ①In CEUS,the perfusion of capillary could be detected in vascular phase.②The concordance of dual-phases enhanced patterns between CEUS and CECT was 73.5%(36/49).The concordance of enhanced level between early parenchymatous perfusion phase in CEUS and pancreatic phase in CECT could achieve 87.8%(43/49).Hypo/hypo enhancement was the most common enhanced pattern of pancreatic carcinoma in CEUS and CECT.③There was no statistical significance between CEUS and CECT in the differential diagnostic.Conclusions The concordance of enhanted patterns between CEUS and CECT is satisfactory.CEUS is similar to CECT in the differential diagnosis of s-FLPs.CEUS would become an important non-invasive diagnostic method for s-FLPs.
4.Contrast enhanced ultrasound features of hepatic angiomyolipoma
Zhu WANG ; Huixiong XU ; Xiaoyan XIE ; Mingde Lü ; Zuofeng XU ; Guangjian LIU
Chinese Journal of Ultrasonography 2009;18(6):499-502
Objective To investigate the features of hepatic angiomyolipoma(AML) on contrast enhanced ultrasound (CEUS). Methods Ten pathologically proved AML lesions in 9 patients were evaluated by using baseline ultrasound and CEUS. CEUS was performed with contrast pulse sequencing technique and the contrast agent of SonoVue. Results On baseline ultrasound, 7 lesions exhibited mixed echoic,which was obvious hyperechoic combined with partly of hypoechoie; 3 lesions exhitited obvious hypereehoic. On color Doppler flow imaging artery signals were detected in all lesions. And the lesions had plenty or slightly plenty of artery supply,with resistive index about 0.53 4±0.10 (0.48~0.62). On CEUS, in the arterial phase, 9 lesions exhibited hyper-enhanced. In the portal phase, 5 lesions exhibited iso-enhancement,1 lesion was slightly hyper-enhancement and 3 lesions was hypo-enhancement. In the late phase 6 lesions were iso-enhancement and 3 lesions were hypo-enhancement. One lesion was all hypo-enhancement in all three phases. Conclusions There are some characteristic manifestations of hepatic AML in CEUS, which are helpful for the diagnosis of hepatic AML in a way,but we still need more experiences.
5.The value of ultrasonic cholangiography with contrast agent SonoVue:primary experience ZHOU Lu-yao,
Luyao ZHOU ; Xiaoyan XIE ; Huixiong XU ; Ming KUANG ; Zuofeng XU ; Xiaoyu YIN ; guangjian LIU ; Mingde Lü
Chinese Journal of Ultrasonography 2008;17(9):763-767
Objective To evaluate the feasilibility of ultrasonic cholangiography(USC)with contrast agent SonoVue in evaluating the obstructive bile duct diseases.Methods Twenty patients with obstructive jaundice(choledocholithiasis in 4,post-operative biliary strictures in 2 and malignant tumors in 14)underwent uhrasound-guided percutaneous transhepatic cholangiodrainge drainage(PTCD).Afterward,USC with contrast agent SonoVue administrated from the PTCD tube and percutaneous transhepatic cholangiography(PTC)were carried out in each patient.By using the surgical or PTC findings as reference standard,accuracy of USC in determining the obstructive level and cause of bstructive was evaluated.Results ①The visualization of contrast agent SonoVue was successfully obtained in all 20 patients,three order of bile duct was visualized in 19 patients.The visualization of the ultrasound contrast agent persisted more than 6 min.There was no side effect occurred during the procedure and no uncomfortable complaint after the procedure.②USC determined correctly in 18 cases.Compared with surgical or PTC findings,the accuracy of USC in determining obstructive levels was 90.0%(18/20),and the accuracy in determining the obstructive cause was 85.0%(17/20).Conclusions As a new and safe technique for cholangiography,USC is comparable to PTC in displaying the intrahepatic bite duct and determining the obstructive levels in patients with obstructive jaundice.
6.Characterization of renal cellular carcinoma with contrast-enhanced ultrasound
Zuofeng XU ; Guangsheng WAN ; Xiaoyan XIE ; Mingde Lü ; Huiziong XU ; Guangjian LIU ; Bei HUANG
Chinese Journal of Ultrasonography 2008;17(8):694-696
Objective To conclude the characterization of renal cellular carcinoma(RCC)with contrast enhanced ultrasound.Methods Seventy patients(seventy-two nodules)with RCC,which were confirmed by operation and biopsy underwent conventional ultrasound and contrast-enhanced ultrasound(CEUS).Microbubble agents SonoVue and contrast pulse sequence(CPS)were used.The conventional uItrasonographic characterization and the enhancement patterns of lesions were analyzed.Results On baseline sonography,the numbers of lesions that showed hypoechogenicity,isoechogenicity,and hyperechogenicity were 44.4%(32/72),25.0%(18/72)and 30.6%(22/72),respectively.Only 28 lesions(38.9%)showed flow signals on color Doppler sonography,the mean maximum velocity of which WSS(43.7±16.8)cm/s(range,24.8-95 cm/s),and the mean resistance index was 0.635±0.11(range.0.52-0.83).Sixty-three(87.5%)lesions were hyper-vascular in cortical phase.Among them forty-eight(76.2%)lesions were hypo-enhanced,and fifteen(23.8%)lesions were still hyper-vascular in late phase.The remaining nine hypervascular nodules in cortical phase were still hyper-enhancing in late phase.Fifty-four(75.0%)lesions were inhomogeneous enhancement.and pseudocapsule was observed in sixty-three(87.5%)RCC lesions.Conclusions The enhancement patterns of RCC are characteristic,and CEUS may be helpful in differential diagnosis of focal renal lesions.
7.Enhancement pattern of hilar cholangiocarcinoma: comparison between contrast-enhanced sonography and contrast-enhanced computed tomography
Lida CHEN ; Huixiong XU ; Xiaoyan XIE ; Zuofeng XU ; Guangjian LIU ; Mingde Lü
Chinese Journal of Ultrasonography 2008;17(7):590-593
Objective To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced sonography(CEUS) and contrast-enhanced computed tomography(CECT). Methods Thirty-two hilar cholangiocarcinoma lesions in 32 patients were evaluated by CEUS and CECT. CEUS was performed with contrast agent of SonoVue and low mechanical index contrast specific mode. CECT was performed with contrast media of Ultravist and a standard biphasic helical CT scanning protocol. Results In arterial phase of CEUS and CECT,the numbers of the lesions showing hyper-enhancement were 14 (43.8 % ) and 12 (37.5 % ), iso-enhancement were 14 (43.8%) and 9(28. 1%),hypo-enhancement were 4(12.5%) and 11(34.4%),respectively (P = 0. 162).Three lesions (9.4%) showed periphery rim-like hyper-enhancement and 29 (90.6%) showed diffuse homogeneous or heterogeneous enhanced of the whole tumor on CEUS, whereas for CECT the number were 2 (6. 3%) and 30 (93. 8%) respectively ( P = 1. 000). In portal phase, the numbers of the lesions showing hypo-enhancement on CEUS and CECT were 30 (93.8 % ) and 23 ( 71.90% ), iso-enhancement were 1 ( 3.1 % ) and 8 ( 25.0 % ), hyper-enhancement were 1(3. 1%) and 1 (3. 1%), respectively ( P = 0. 046). The portal vein invasion was correctly detected in 16 ( 84. 2 % ), 17 (89. 5 % ), 15 (78.9 % ) lesions with baseline ultrasound, CEUS and CECT, respectively. CEUS and CECT correctly diagnosed 30(93.8% ) and 25 (78. 1% ) lesions prior to operation (P = 0. 125). Conclusions The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma was prone to show hypo-enhancement on CEUS. CEUS and CECT has similar diagnostie efficacy prior to operation.
8.Classifying of hilar cholangiocarcinoma: a comparison study between percutaneous ultrasonic cholangiography and percutaneous transhepatic cholangiography
Luyao ZHOU ; Xiaoyan XIE ; Huixiong XU ; Zuofeng XU ; Keguo ZHENG ; Ming KUANG ; Peifen CHEN ; Mingde Lü
Chinese Journal of Ultrasonography 2010;19(12):1047-1050
Objective To evaluate the accuracy and utility of percutaneous ultrasonic cholangiography in Bismuth staging of hilar cholangiocarcinoma. Methods Thirty patients who underwent surgery and obtained pathologic diagnosis of hilar cholangiocarcincoma were perspectively ruled in this study. All patients with hilar obstruction underwent baseline ultrasound (BUS), percutaneous ultrasonic cholangiography (PUSC) and percutaneous transhepatic cholangiography(PTC) respectively. Taking operative findings as reference standard,the accuracy of the three imaging modalities in staging of hilar cholangiocarcinoma was compared. Results Among 30 patients, the accuracy of classification among BUS, PUSC and PTC was 23.3 % (7/30), 73.3 % ( 22/30 ), 73.3 % (22/30), respectively. There was statistically significant difference between BUS and PUSC, but the difference between PUSC and PTC was not statistically significant.Conclusions As a new technique for cholangiography, PUSC expands the application of ultrasound in evaluating hilar cholangiocarcinoma and is comparable to PTC in classifying hilar cholangiocarcinoma by Bismuth classification.
9.The preparation of targeted microbubble with low immunogenicity
Guangliang HUANG ; Wei WANG ; Xiaoyan XIE ; Huixiong XU ; Zuofeng XU ; Guanjian LIU ; Mingde Lü
Chinese Journal of Ultrasonography 2010;19(12):1079-1081
Objective To prepare targeted micorbubble with low immunogenicity. Methods The microbubbles were produced with different phospholipids and identified by the fluorescent method. Detect the level of C3a after reaction with human serum in vitro with enzyme-linked immunosorboent assay (ELISA) method and the number of microbubble binding with the streptavidin packed on the dish by using the parallel plate flow chamber. Results The level of C3a was (1.037±0.047)ng/ml in MBb group,(1. 326 ± 0. 042)ng/ml in MBe group and ( 1.004 ± 0.031 ) ng/ml in MBc group. The level of C3a in MBb group was significantly lower than that in MBe group( P <0.05),and there was no significantly difference between MBb group and MBc group ( P > 0. 05). The parallel plate flow experiments showed that the number of MBb(15.2 ± 11.3) in each field of view binding with the streptavidin packed on the dish was significantly fewer than that of MBe ( 103.2 ± 28.3) ( P<0.05 ), and there was no significantly difference between MBb and MBc(17.8 ± 11.9) ( P >0.05). Conclusions The targeted microbubble with low immunogenicity has been prepared successfully,which can be used for further experiment in vivo.
10.Comparison study of contrast-enhanced ultrasound and contrast CT on diagnosis of renal cell carcinoma
Zuofeng XU ; Xiaoyan XIE ; Huixiong XU ; Junxing CHEN ; Guangjian LIU ; Mingde Lü
Chinese Journal of Urology 2010;31(7):452-455
Objective To compare contrast-enhanced ultrasound(CEUS)and contrast-enhaneed computed tomography(CECT)on the diagnosis of renal cell carcinoma(RCC). Methods CEUS and CECT were performed on 117 patients(87 men and 30 women)with 124 renal lesions(single nodule in 110 and two nodules in 7)from 2004 to 2008.Among them,there were 63 patients with 65 lesions diagnosed as RCC confirmed by pathology.The tumor enhancement pattern,extent,and dynamic change of CEUS and CECT were compared.The diagnostic efficacy of CEUS and the agreement of CECT and CEUS in diagnosing RCC were analyzed. Results The rate of displaying hypervascular performance on cortical phase,and pseudocapsule enhancement of the RCC lesions by CEUS and CECT were 87.7%(57/65)and 63.1%(41/65),89.2%(58/65)and 69.2%(45/65)(P<0.05).The rate of displaying heterogeneous enhancement were 72.3%(47/65)and 56.9%(37/65)(P>0.05)Using the diagnosis of CECT as reference diagnostic criteria,the sensitivity,specificity,positive predietive value,negative predictive value,and accuracy of CEUS in diagnosing RCC were 89.1%(57/64),91.7%(55/60),91.9%(57/62),88.7%(55/62)and 90.3%(112/124).The agreement of CECT and CEUS in diagnosing RCC was high(κ=0.806). Conclusions CEUS and CECT have the coordinate efficacy in diagnosing RCC.