1.Penehyclidine hydrochloride mediated as antagonist of muscle relaxant in aged with myocardial ischemia
Jian CUI ; Guocai TAO ; Anzhi DENG ; Ziyang ZENG
Journal of Third Military Medical University 2003;0(16):-
Objective To investigate the advantage and safety of penehyclidine hydrochloride as the antagonist of muscle relaxant in aged patients with myocardial ischemia. Methods Sixty cases over 60 years old with myocardial ischemia in ECG were randomized to receive 15 ?g/kg atropine+40 ?g/kg neostigmine (group A),sole 20 ?g/kg penehyclidine hydrochloride (group B),20 ?g/kg penehyclidine hydrochloride +40 ?g/kg neostigmine (group C). Vital signs of antagonism were observed before and after the changes of antagonism. Results All cases had an uneventful anesthesia and operation. After antagonists were administered,heart rate and heart rate variation index increased,respiration became shallow and faster in group A. The heart rate in group B only increased mildly and the muscle tone returned very slowly as the increasing of BIS. The signs were the most desirable such as mildly lower heart rate,the minimal heart rate variation index,faster recover of muscle tone without re-relaxation,slow and deep respiration,and slowly recovered BIS. Conclusion Penehyclidine hydrochloride combined with neostigmine is suitable to reverse the muscle relaxant in aged with myocardial ischemia.
2.Analysis of ultrasonic diagnostic features of juxtapapillary capillary hemangioma
Yifeng LI ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Rui CUI ; Lin SHEN ; Qian LIU ; Wenbin WEI ; Junfang XIAN
Chinese Journal of Ultrasonography 2021;30(2):161-166
Objective:To discuss the characteristics of ultrasound diagnosis of optic disc capillary hemangioma.Methods:The study analyzed retrospectively 7 cases of optic disc capillary hemangioma diagnosed in the Beijing Tongren Hospital from 2015 to 2018. The size, morphology, internal echo, and secondary changes of the lesion were analyzed during ultrasound examination.Color Doppler flow imaging was used to check the blood flow in the lesion.Results:Pre-optic disc occupying lesions could be detected in the ultrasound images of the 7 cases. Lesion size: average base diameters (5.39±1.90)mm×(4.79±1.28)mm, average height (3.61±1.37)mm. Lesion morphology: 5 cases were round, and 2 cases were irregular. Echo within the lesion: 3 cases had medium echo inside the lesion, and 4 cases had high echo inside the lesion. Internal echo characteristics: 5 cases had uniform echo, and 2 cases had uneven echo. Secondary changes: 6 cases had secondary retinal detachment and vitreous opacity, and 1 cases was accompanied by retinal hemangioma in other parts. In all cases, blood flow signals could be detected inside the space-occupying lesions, which were in the form of branches, stripes or spots, and the blood flow spectrum showed a parallel spectrum of arteries and veins.Conclusions:Ultrasound examination of optic disc capillary hemangioma has certain characteristics, which can provide a valuable follow-up basis for clinical diagnosis.
3.The current state and prospect of open elbow arthrolysis for post-traumatic elbow stiffness
Ziyang SUN ; Feiyan WANG ; Haomin CUI ; Shiyang YU ; Shuai CHEN ; Hao XIONG ; Wei WANG ; Cunyi FAN
Chinese Journal of Orthopaedic Trauma 2019;21(8):727-732
The elbow is more susceptible to motion loss than other joints after trauma,and elbow stiffness leads to functional impairment in the upper limb and interferes with daily activities.Open arthrolysis is the most common and classical treatment for post-traumatic elbow stiffness.In this paper,we review the treatment protocols like preoperative clinical evaluation,arthrolysis strategies and postoperative rehabilitation program for post-traumatic elbow stiffness,discuss relevant issues and assess their prospects.
4.Association of the APP usage frequency and the effect in smoking cessation clinic intervention Association of the APP usage frequency with the effect in smoking cessation clinic intervention
Xiaowen WEI ; Rui QIN ; Anqi CHENG ; Xinmei ZHOU ; Zheng SU ; Ziyang CUI ; Jinxuan LI ; Dan XIAO ; Chen WANG
Chinese Journal of Health Management 2023;17(9):661-667
Objective:To explore the association between the frequency of using smoking cessation application (APP) and the effect of smoking cessation in smoking cessation clinic.Methods:A clinical trial with a non-randomized controlled design was conducted in the smoking cessation clinic of China-Japan Friendship Hospital from July 2019 to June 2021. Participants were given a comprehensive smoking cessation intervention of mobile APP combined with bupropion. The primary outcome measures were carbon monoxide validated sustained abstinence at 9-12 weeks.Results:A total of 187 participants were included in the final analysis. After 12-week intervention, the sustained abstinence at 9-12 weeks was 42.2%. For the frequency of APP use, 20.9% (39/187) of the participants used it≥6 days per week, 62.0% (116/187) used it 2-5 days per week, and 17.1% (32/187) used it≤1 day per week. Multivariate analysis showed that smoking cessation rate was associated with smoking duration, cigarettes smoked per day and frequency of APP use. Participants with higher frequency of APP use had a higher likelihood of quitting smoking ( OR=4.95, 95% CI: 1.32-18.63). Conclusion:The increased frequency of mobile smoking cessation APP use is associated with higher probability of quitting smoking in smoking cessation clinic.
5.Comparative study on specific chromatograms and main active components of wild and cultivated rhizomes of Paris polyphylla var. yunnanensis.
Ke ZAN ; Yu-Ming GAO ; Gan CUI ; Jie LIU ; Li-Nong GUO ; Jian ZHENG ; Shuang-Cheng MA
China Journal of Chinese Materia Medica 2017;42(15):3011-3016
The present study is to compare specific chromatograms and main acitive components between wild and cultivated rhizomes of Paris polyphylla var. yunnanensis by HPLC. HPLC analysis was performed on a Waters XSelect HSS T3 C₁₈ clumn (4.6 mm×250 mm, 5 μm), with a mobile phase consisting of acetonitrile (A)-water (B) at a flow rate of 1 mL•min⁻¹ (0-50 min,30%-50%A;50-80 min,50% A,80-85 min,50%-30%A;85-100 min,30% A). The detection wavelength was 203 nm and the column temperature was controlled at 30 ℃, and the injection volume was 10 μL. HPLC specific chromatograms of wild and cultivated rhizomes of P. polyphylla var. yunnanensis were established and nine steroidal saponins were simultaneously determined by the above method. The mean contents of paris saponin Ⅶ, paris saponin H and total average contents of four pennogenyl saponins in Rhizomes of wild samples were significantly higher than those of cultivated ones. However, this result is opposite from the average content of paris saponin Ⅰ and total average contents of five dioscins in the wild and cultivated samples. Because the significant differences occurred for the specific chromatograms and main active components between the wild and cultivated P. polyphylla var. yunnanensis, much more pharmacological and clinical researches are therefore necessary.
6.Relationship between HLA⁃A rs3132682 and susceptibility to hepatocellular carcinoma in Yanbian area
Xia Liu ; Hesong Cui ; Xue Bai ; Ying Cui ; Ziyang Sun ; Guang Jin
Acta Universitatis Medicinalis Anhui 2023;58(1):156-161
Objective:
To study the relationship between the single nucleotide polymorphism of HLA⁃A rs3132682 and the risk of liver cancer.
Methods:
The author selected 291 cases of liver cancer patients in Yanbian area as the experimental group and 272 healthy people as the control group. The genotypes and allele frequencies of the two loci were detected by MassARRAY SNPS mass spectrometry. Odds ratio (OR) and 95% confidence interval (CI) were calculated by unconditional logistic regression to evaluate the risk of liver cancer in patients with different genotypes.
Results:
There were G and C alleles in HLA⁃A rs3132682 locus , GG , GC and CC genotype. After adjusting for confounding factors in HLA⁃A rs3132682 locus , there was correlation between CC genotype and the risk of liver cancer compared with GG genotype (P < 0. 05) . Stratification analysis showed that compared with the population with CG + GG genotype , the Korean population with CC genotype increased the risk of liver cancer by 3. 331 times.
Conclusion
The single nucleotide polymorphism of HLA⁃A rs3132682 is correlated with the risk of liver cancer in Yanbian area.
7.Agreement of biometry parameters measured by IOLMaster 700 and Pentacam AXL in cataract eyes
Dongjun LI ; Wenli YANG ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Junfang XIAN
Chinese Journal of Experimental Ophthalmology 2020;38(11):962-966
Objective:To compare the agreement of biometric parameters measured by a new swept-source optical coherence tomography IOLMaster 700 and a new Scheimpflug imaging combined with partial coherence interferometry biometer Pentacam AXL in cataractous eyes.Methods:A cross-sectional study was performed.A total of 146 eyes from 76 cataract patients were enrolled in Beijing Tongren Eye Center from 2 to 11 in January 2018, including 69 eyes in 36 males and 77 eyes in 40 females, the age ranged from 35 to 88 years, the mean age was (64.52±11.36) years.Axial length (AL), mean keratometry (Km), anterior chamber depth (ACD), central corneal thickness (CCT) and white-to-white (WTW) were measured with IOLMaster 700 and Pentacam AXL, respectively.The differences and correlations of the biometry parameters between the two devices were assessed.Bland-Altman method was used to evaluate the agreement of these parameters between the two devices and the 95% limits of agreement was calculated.This study adhered to the tenets of the Declaration of Helsinki and was approved by an Ethics Committee of Beijing Tongren Hospital (TRECKY2018-049).Results:The mean values of the AL measured by IOLMaster 700 and Pentacam AXL were (24.03±1.72)mm and (23.98±1.73)mm, Km were (44.04±1.71)D and (43.88±1.72)D, ACD were (3.24±0.47)mm and (3.28±0.47)mm, WTW were (11.82±0.51)mm and (11.49±0.49)mm, respectively.Compared with the values in Pentacam AXL, the AL, Km and WTW were larger while ACD was smaller in IOLMaster 700 with significant differences ( t=18.06, 8.94, 23.83, -15.36, all at P<0.01). The mean CCT values from the IOLMaster 700 and Pentacam AXL were (534.18±30.12)μm and (533.42±28.71)μm, respectively, with no significant difference ( t=1.04, P=0.30). The AL, Km, ACD, CCT and WTW from IOLMaster 700 were highly correlated with those from Pentacam AXL ( r=0.999, 0.992, 0.998, 0.956, 0.942; all at P<0.01). The Bland Altman analysis showed that the 95% limits of agreement of AL, Km, ACD, CCT and WTW were-0.02-0.11 mm, -0.27-0.59 D, -0.10-0.02 mm, -16.5-18.1 μm and 0.00-0.67 mm. Conclusions:IOLMaster 700 and Pentacam AXL have good agreements and narrow 95% limits of agreement in the measurements of AL, ACD, CCT, which can be clinically interchangeable.The 95% limits of agreement of WTW and Km are out of the clinically acceptable range, so the WTW and Km measured by the two devices are not interchangeable.
8.Agreement of biometry parameters measured by IOLMaster 700 with IOLMaster 500 in cataract eyes with high myopia
Lin SHEN ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Wenli YANG
Chinese Journal of Experimental Ophthalmology 2019;37(4):292-296
Objective To compare the agreement of axial length (AL),anterior chamber depth (ACD) and keratometry measured by IOLMaster 500 with IOLMaster 700 in cataract eyes with high myopia.Methods A cross-sectional study was performed.One hundred and fifty-two eyes of 87 cataract patients with high myopia were included from September to October 2017 in Beijing Tongren Hospital.The best corrected visual acuity (BCVA) was 0.05-1.0,and the refraction power was-6.25--21.00 D,with an average power of (-13.625 ± 7.375) D.A L,ACD and keratometry (Kf,Ks) were measured by IOLMaster 700 and IOLMaster 500 respectively for all the eyes.The eyes were assigned to AL>26-≤28 mm group,AL>28-<30 mm group and AL≥30 mm according to the results of IOLMaster 500.The measured differences between two devices were assessed using paired samples t-test,and the measured consistency of the two devices was evaluated using Bland-Altman agreement analysis.This study protocol was approved by Ethics Committee of Beijing Tongren Hospital and complied with Declaration of Helsinki.Results There were no significant differences in the AL and Kf measured by the two devices in all the three groups (all at P>0.05).Both ACD and Ks values measured by IOLMaster 700 were lower than those by IOLMaster 500 (both at P<0.05),which were clinically acceptable.The percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,2.17% and 3.03% for AL differences and 4.10%,4.34% 和 3.03% for Kf difference in the three groups.Significant differences were found in ACD and Ks between IOLMaster 700 and IOLMaster 500 at a clinically acceptable level (both at P<0.05),and Bland-Altamn agreement analysis showed that the percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,4.34% and 3.03% for both ACD and Ks differences in the three groups.Conclusions There is a good agreement in AL,ACD,Kf and Ks measured by IOLMaster 700 with IOLMaster 500 and is clinically interchangeable in cataract eyes with high myopia.However,IOLMaster 700 is better because it can provide the OCT image of macula.
9.Value of color Doppler ultrasonography in the evaluation of retinoblastoma
Rui CUI ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Lin SHEN ; Wenli YANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2017;14(10):725-729
Objective To evaluate the value of color Doppler ultrasonography in the diagnosis of retinoblastoma (RB). Methods One hundred and eighty-two patients (199 eyes) with RB confirmed by pathology from June 2012 to June 2016 in Beijing Tongren Hospital were included in this study. The two-dimensional gray-scale image and color Doppler imaging ultrasound features were observed. The variance analysis was used to compare the width and height of different morphologies. Comparison the detection rate of the two methods by χ2test.Results The ultrasonography of RB was characterized by substantial masses of the eyeball, which could be hemispherical, spherical, irregular, filled with vitreous cavity, or diffuse along the retina. The results of variance analysis showed statistical difference in three shapes (F= 29.134, 24.474, P<0.001),LSD-t test showed difference between hemisphere and spherical,spherical and irregular shape, hemispherical and irregular shape. The t values of basal width were 2.457,-2.333 and-6.205, respectively and all P < 0.05 respectively. The t value of height were 3.917,-6.711 and-7.244, respectively and all P < 0.05.All lesions were uneven echo. Calcification and localized low echo area within the mass was observed in 93.47% (186/199) and 52.76% (105/199) eyes respectively. 46.73% (93/199) retinal detachment and 31.16% (62/199) vitreous opacity is present. Colorful blood flow signals extended from the central retinal vessels could be seen inside the masses of 98.49% (196/199) eyes. Two-dimensional image and color Doppler imaging ultrasound were consistent with the pathological diagnosis in 96.5% (192/199) and 99.5% (198/199) RB cases, respectively.The difference was statistically significant (χ2=4.167, P=0.031). Conclusions Retinoblastoma has characteristic ultrasound manifestations. Color Doppler ultrasonography is a valuable clinical tool in the diagnosis of RB.
10.Diagnostic value of conventional ultrasound, color Doppler ultrasonography and contrast-enhanced ultrasound in sub-retinal hemorrhage
Lin SHEN ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI
Chinese Journal of Medical Ultrasound (Electronic Edition) 2017;14(10):730-733
Objective To explore the value of conventional ultrasound, color Doppler ultrasound and contrast-enhanced ultrasound (CEUS) in the diagnosis of sub-retinal hemorrhage. Methods A total of 26 patients with sub-retinal hemorrhage were examined by conventional ultrasound, color Doppler ultrasound and CEUS. The results of medical history, ultrasound, color Doppler ultrasound and CEUS were recorded and analyzed.And the difference of the detection rate between the three methods was analyzed by χ2test. Results The mean fundus diameter of the sub-retinal hemorrhage was (5.31±2.21) mm, and the mean height was (1.97±0.98) mm. In twenty-two eyes (84.6%) the lesions were located in the posterior pole of the ocular wall, while in two eyes (7.7%) the lesions were located in the equator and peripheral of the ocular wall. Seven eyes (26.9%) had dome-shaped mass, ten eyes (38.5%) had flat-shaped mass, and nine eyes (34.9%) had irregular-shaped mass. The echogenecity of the lesions was homogeneous in twelve eyes (46.2%), and heterogeneous in fourteen eyes (53.8%). The lesions showed clear margin in seventeen eyes (65.4%). Blood flow signals can be detected in twenty-three eyes (88.5%). The surface of the lesions was filled by contrast-medium in all cases. The detection rate of sub-retinal hemorrhage with color Doppler and contrast-enhanced ultrasound was higher than that of conventional ultrasound, and the difference was statistically significant. Conclusion Color Doppler ultrasonography and CEUS can provide a powerful basis for the clinical diagnosis of sub-retinal hemorrhage, while CEUS has higher application value.