3.Study on the Fermentation Condition of Steroid 15?-Hydroxylation by Penicillium raistrickii
Jun LI ; Xu GENG ; Liang WENG ; Zi-Rong WU ;
Microbiology 1992;0(05):-
The fermentation conditions which affect C-15? hydroxylation o f 18-methyl-estr- 4-ene-3,17-dione were investigated. As the key step in the Hydroxylation, the dissolution of substrate was focused on. Tween80, MeOH, DMSO,?-CD and 2-HP?CD were studied to improve the dissolvability of 18-met hyl-estr-4-ene-3,17-dione.The other factors such as pH, substrate concent ration and aeration strategies which affected conversion rate were also resea rched. As a result, the conversion rate can be up to 60% in shake flask and ach i(eve 50% in fermentor,which would overcome the disadvantage of 15?-hydroxyl -18-methyl-estr-4-ene-3,17-dione chemosynthesis and provide a good techn ics to industry.
4.Cerebral oxygen metabolism during liver transplantation in patients with liver cirrhoses
Zi-Qing HEI ; Shang-Rong LI ; Gang-Jian LUO ;
Chinese Journal of Anesthesiology 1994;0(06):-
Objective To investigate the changes in cerebral oxygen metabolism during liver transplantation in patients with liver cirrhoses.Methods Sixteen ASAⅢorⅣpatients with liver cirrhoses(14 male,2 female)aged 25-67 yrs,weighing 45-80 kg undergoing liver transplantation were studied.Radial artery was cannulated for direct BP monitoring and blood sampling.Swan-Ganz catheter was placed in pulmonary artery (PA)via right internal jugular vein(IJV)for cardiac output(CO)monitoring and sampling mixed venous blood. Left IJV was cannulated and the catheter was advanced cephalad until jugular bulb for blood sampling.Anesthesia was induced with midazolam,fentanyl,propefol and vecuronium and maintained with isoflurane inhalation and intermittentⅣboluses of fentanyl and vecuronium.The patients were mechanically ventilated after tracheal intubation.PaCO_2 was maintained between 30-45 mm Hg.Blood samples were taken from radial artery,pulmonary artery and jugular bulb simultaneously for blood gas analysis before operation(T_0,baseline),10 min before anhepatic phase(T_1)20 min after onset of anhepatic phase(T_2),30 min after graft reperfusion(T_3)and at the end of operation(T_4).Oxygen delivery(DO_2),oxygen consumption(VO_2),oxygen content of jugular bulb blood (CjvO_2),cerebral arterial-venous oxygen content differences(Ca-jvO_2)cerebral oxygen extraction ratio(CERO_2) and CBF/CMRO_2 were calculated.Results The mean duration of operation was(364?51)min and the mean intraoperative blood loss was(1340?430)ml.CO was significantly increased before anhepatic phase(T_1), during neohepatic phase(T_3)and at the end of operation(T_4)but decreased during anhepatc phase(T_2)as compared with the baseline value at T_0.Hb,CaO_2,Ca-jvO_2 and CERO_2 were all decreased while SjvO_2 and CBF/ CMRO_2 were increased during operation;DO_2,VO_2 and CjvO_2 were decreased during anhepatic phase;DO_2 was increased during other phases;VO_2 was increased at the end of operation as compared with the baseline(T_0)(P<0.05 or 0.01).Conclusion There is no cerebral oxygen deficiency during liver transplantation in patients with liver cirrhoses.
5.Study and evaluation of preparation of silybin PLGA microspheres by stainless steel membrane emulsification technique.
Kun RONG ; Bin-Li LIU ; Mu-Zi LI ; Liang-Liang XU ; Xin YI ; Cheng-Ke CAI
China Journal of Chinese Materia Medica 2014;39(7):1229-1233
OBJECTIVEThe aim of the present study was to prepare uniform-sized silybin loaded poly (lactic-co-glycolic acid) (PLGA) microspheres in study of silybin with stainless steel membrane.
METHODSilybin PLGA microspheres were prepared by stainless steel membrane emulsification. The preparation conditions were optimized by single-factor test and orthogonal experiment, and evaluating the mean diameters, the particle size distribution, drug loading, entrapment efficiency and morphology of microsphere.
RESULTPrepared microspheres were round and surface was smooth. The mean diameter was (4.961 +/- 0.56) microm. The span was (1.75 +/- 0.18). The entrapment efficiency was (54.997 +/- 4.05)% and the average drug loading was (23.6 +/- 1.70)%.
CONCLUSIONThe stainless steel membrane emulsification can be used to prepare the silybin PLGA microspheres. The mean diameters of the silybin PLGA microspheres can be controlled in certain level. Stainless steel membrane emulsification has great potentiality exploitation and utilization.
Drug Compounding ; methods ; Emulsions ; chemistry ; Lactic Acid ; chemistry ; Microspheres ; Particle Size ; Polyglycolic Acid ; chemistry ; Silymarin ; chemistry ; Stainless Steel ; chemistry
6.Negative Inotropic Effects of ?_3-Adrenoceptor Autoantibodies from Children with Heart Failure on Isolated Cardiomyocytes of Adult Rats
li, YAN ; jin, WANG ; wen-xiao, LI ; zi, YAN ; xiao-ping, LV ; hui-rong, LIU
Journal of Applied Clinical Pediatrics 1986;0(01):-
Objective To explore the effects of the autoantibody against the second extracellular loop of ?3-adrenoceptor(?3AR)from children with heart failure on isolated cardiomyocytes of adult rats.Methods The synthetic peptide corresponding to the sequence of the se-cond extracellular loop(176-202 amino acid residues)of the human ?3AR was used as the antigen to screen the anti-?3AR autoantibodies from the sera of the 50 children with heart failure and 50 healthy children by enzyme linked immunosorbent assay(ELISA);IgG in the children with heart failure of positive autoantibodies sera was purified.The effects of purified IgG per each group on contractile response of isolated cardiomyocytes of adult rats were observed using motion-edge detection system and double-provocation fluorescence photomultiplier system.Results Among the 50 children with heart failure,the anti-?3AR autoantibodies positive rate was 30%(15/50 cases),and ob-viously higher than that of healthy children[12%(6/50)cases,P
7.Restoration of femoral offset in total hip arthroplasty.
Chinese Journal of Surgery 2004;42(16):997-1000
OBJECTIVETo explore the factors effecting restoring femoral offset and the relation between femoral offset and hip abductor strength during total hip arthroplasty (THA).
METHODSNinety-nine THA for 81 patients were performed from March 1998 to January 2002. And follow-up was finished. There were 53 women and 28 men and the average age was 57 years (29 to 80). The right hip had been replaced in 28 cases, the left in 35 cases and the bilateral in 18 cases. The mean duration of clinical and roentgenographic follow-up was 36.8 months (range, 19 approximately 66 months). A posterolateral approach was used in all THA. The femoral offset and the abductor lever arm were measured from each radiograph. The measurement of the hip abduction strength was made for some THA by the Cybex machine. Statistical data analysis was performed by SPSS10.0 software.
RESULTSFemoral offset correlated positively with the length of the abductor lever arm (r = 0.613; P < 0.001). Simple regression analysis showed that femoral offset was significantly and positively related to the length of femoral neck and neck-shaft angle (r = 0.451, P = 0.001; r = 0.567, P < 0.001). There was a highly significant and positive correlation between femoral offset (and consequently abductor lever arm) and hip abductor strength (r = 0.500, P = 0.009; r = 0.477, P = 0.014).
CONCLUSIONSIt is very important to template both sides of hip preoperatively for restoring femoral offset in THA. Femoral component with more anatomical neck-shaft angle will be used with the increase in the femoral neck length.
Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; methods ; Female ; Femur ; physiology ; Follow-Up Studies ; Hip Joint ; physiology ; Hip Prosthesis ; Humans ; Male ; Middle Aged ; Range of Motion, Articular ; Treatment Outcome
9.The study of anterior sclera thickness and associated ocular parameters
Mei, LI ; Yu, CAI ; Ying-zi, PAN ; Rong-hua, QIAO ; Yuan, FANG ; Jie, WANG
Chinese Journal of Experimental Ophthalmology 2013;(1):81-85
Background The condition of the sclera is associated with many ocular diseases.The measurement of human scleral thickness in vivo is helpful for us to understand the features of the sclera and related diseases.Objective The present study was to measure the anterior sclera thickness(AST) in patients with senile cataract and to analyze the relationship among AST and other associated ocular parameters.Methods This study was approved by the Ethic Commission of First Hospital of Peking University.Written informed consent was obtained from each individual prior to examination.One hundred and five senile cataract patients were recruited in this study.Central corneal thickness (CCT),corneal curvature (CCV) and axial length were measured using ultrasonic pachymeter,keratometer,and A-scan unit,respectively.The AST was measured at 2 mm posterior to the scleral spur in the temporal meridian using ultrasound biomicroscope (UBM).The differences of CCT,CCV,ocular axial length and AST between bilateral eyes and the different sexes were compared by the Paired test and independent sample t test.The correlations among various parameters were assessed by the Pearson linear correlation analysis.The differences of CCT and AST among different axial length groups were evaluated by one-way ANOVA.Results No significant differences were found in the CCT,CCV,axial length and AST between bilateral eyes (t =0.584,P =0.561 ; t =1.161,P =0.248 ; t =0.140,P =0.889 ; t =0.342,P =0.773).Temporal AST at 2 mm posterior to the sclera spur was (0.589 ±0.051)mm in the right eyes.An insignificant decline in CCT was found in the male group compared with the female group (right eyes:t =0.469,P =0.641 ; left eyes:t =0.465,P =0.643).However,compared with the female group,the increase of axial length,reduction of the mean CCV value and enhancement of the mean AST were observed(right eyes:all P<0.01 ;left eyes:all P<0.01).CCV showed a negative correlation with ocular axial length (r =-0.50,P<0.01),but no significant correlation was found among age,CCT,ocular axial length and AST(P>0.05).No remarkable differences were found in CCT and AST among the various axial length groups (CCT:F =0.998,P=0.372;AST:F=1.919,P=0.383).Conclusions In senile cataract patients,correlation is not found between AST and CCT;the increase of axial length is not associated with the thinning of the eyeball wall to a certain extent.Differences exist in some ocular parameters between different sexes.
10.Measurement of anterior scleral thickness and its correlation with central corneal thickness and axial length in different types of glaucoma patients
Mei, LI ; Rong-hua, QIAO ; Ying-zi, PAN ; Yu, CAI ; Yuan, FANG ; Jie, WANG
Chinese Journal of Experimental Ophthalmology 2013;(3):249-253
Background A close relation between sclera thickness and glaucoma has been determined.Clinical features vary in different types of glaucoma patients,which hints that the scleral thickness might be distinct among these patients.Objective The aim of this study was to investigate the differences of central corneal thickness(CCT),anterior scleral thickness(AST) and axial length in glaucomatous patients.Methods This study was approved by the Ethic Commission of First Hospital of Peking University.Written informed consent was obtained from each individual prior to the examination.A retrospective descriptive study was designed.One hundred and sixty consecutive patients were recruited from March,2009 to November,2010 in First Hospital of Peking University,including 35 eyes with primary angle closure glaucoma(PACG) (35 cases),34 eyes with primary open-angle glaucoma POAG) (34 cases),37 eyes with normal tension glaucoma(NTG) (37 cases)and 17 eyes of ocular hypertension OHT) (17 cases).Thirty-seven eyes of 37 subjects with incipient cataract served as the control group.CCT and ocular axial length were measured with ultrasonic pachymeter and A-scan unit,respectively,and AST at the temporal quadrant 2 mm posterior to the scleral spur was measured by ultrasonic biomicroscopy (UBM).The measuring parameters among different groups were compared by analysis of covariance,and the correlations of AST,CCT with ocular axial length were analyzed using Pearson linear correlation and linear regression.The differences and correlation of CCT,AST and AL among five groups were analyzed.Results The CCT values in PACG group,POAG group,NTG group,OHT group and control group were (535.54 ± 5.20),(550.47 ± 5.28),(521.61 ± 5.07),(575.75 ± 7.76) and (535.06± 5.06) μm,respectively,showing a significant difference among them (F =9.560,P =0.000),and the CCT value of OHT group was increased in comparison with POAG group,PACG group,NTG group and control group(all P =0.000).The CCT of the POAG group was thicker than that in the PACG group,NTG group and control group(P=0.046,0.000,0.040).No significant difference was found in CCT among NTG group,PACG group and control group(P=0.950,0.060).The AST values of PACG group,POAG group,NTG group,OHT group and control group were(0.593±0.050),(0.600±0.050),(0.592-±0.060),(0.610-±0.060) and(0.604±0.060) mm,respectively,showing a insignificant difference among them (F =0.700,P =0.590).The axial length in the patients with PACG was shorter than that of the POAG group,NTG group,OHT group and control group (all P =0.000).The Pearson correlation analysis showed significantly positive correlation between CCT and AST in POAG group and NTG group(r=0.445,P=0.008;r=0.400,P=0.014).Conclusions This study confirms that there is dissimilarity in CCT but not in AST among different types of glaucomatous patients.The changes of CCT and AST are consistent in POAG and NTG patients.