1.Dosimetric comparison of jaw tracking technique with static jaw technique in intensity-modulated radiotherapy for preoperative radiotherapy of rectal cancer
Zhongsu FENG ; Hao WU ; Fan JIANG ; Zhuolun LIU ; Jinsheng CHENG ; Xu SU
Chinese Journal of Radiological Medicine and Protection 2014;34(12):938-941
Objective To compare the dosimetric difference between jaw tracking technique (JTT) and static jaw technique (SJT) in dynamic intensity-modulated radiotherapy (IMRT) for preoperative radiotherapy of rectal cancer patients.Methods Jaw tracking and static jaw were used to develope the intensity-modulated plans for 10 patients respectively.For all the patients,the dose to surrounding tissues was minimized as low as possible,the 95% volume of the planning target volume (PTV) and planning gross target volume (PGTV) satisfy the prescribed dose.The doses of the planning target volumes,organs at risk and normal tissue were detected by dose-volume histogram.Two groups of treatment plan dose were verified by ionization chamber array 2D-Array 729 and OCTAVIUS (PTW) phantom.Results The treatment plans of two groups could satisfy the clinical requirements.There was no significant difference between the maximum and the mean dose of target.The volumes of jaw tracking dynamic intensity-modulated radiotherapy were lower,including the V5,V10,V20,V30,V40 (volumes receiving 5,10,20,30 and 40 Gy,respectively),mean dose(D) for body and V10,V20,V30,D for bilateral femoral head,bladder,and small intestine.There was significant difference for the results (t =-2.32-12.24,P <0.05).The verification results showed that the treatment plans were all passed the dosimetric verification.Conclusions Jaw tracking intensity-modulated radiotherapy and jaw fixed IMRT plan could achieve equal dose coverage in patients with rectal cancer,while jaw tracking techniques could reduce normal tissue dose and organs at risk dose.
2.The performance of plastic scintillator detector in photon and electron beam
Meijiao WANG ; Kaining YAO ; Sha LI ; Haizhen YUE ; Zhuolun LIU ; Fan JIANG ; Hao WU ; Ruoxi WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(3):205-211
Objective:To investigate the performance of W2 plastic scintillator in megavolt photon and electron beams.Methods:The photon and electron beam energy provided by linear accelerator was used to collect data of the W2 scintillator. The parameters include the electrometer reading stability, W2 dose and dose rate linearity, and angular response. And the dose uncertainty of the W2 correction factors was also investigated.Results:The standard deviation of the electrometer reading stability was between 0.03 and 0.47. The linear regression factors of W2 dose were all 1.0; the maximum deviation of the dose rates was 0.61%. The Cerenkov light radiation correction factor(CLR) for 6 and 10 MV were 0.741 and 0.746, respectively, and the CLR for 6, 9, 12 and 15 MeV were 0.750, 0.753, 0.757 and 0.757, respectively. The maximum deviation of dose uncertainty for 15 MeV was 3.15%.Conclusions:The signal obtained by the blue and green channel was no angular dependence, the same as the high-energy electron beam, which verified that the Cerenkov radiation correction factor has good linearity. W2 plastic scintillator can be applied to non-coplanar radiotherapy dosimetry.
3.Performance comparison of four common LINAC daily QA instruments
Qiaoqiao HU ; Yibao ZHANG ; Zhuolun LIU ; Jian ZHANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2015;35(7):532-535
Objective To compare the performances of four commercially available LINAC daily QA instruments.Methods The dosimetric stability of a LINAC including central axis output,flatness and symmetry were verified and fine-tuned using a 3-dimensional water phantom,dosimeters and ionization chambers.The baseline of the four instruments including LINA-C,QUICK-C,BEAM-C and QA3 were set thereafter.Daily measurements of LINAC were conducted with these instruments respectively and the results were compared.Arbitrary errors (CAX and SYM) beyond TG-142 tolerances were introduced to the LINAC to test the sensibilities of each instrument in detecting these changes.Results Relative to the baseline that were measured by the 3-dimensional water phantom and dosimeters,the results monitored by the four instruments were comparable.The maximum disparities of the CAX,FLAT,and SYM were 0.5% (LINA-C),-0.45% (QUICK-C),and 0.5% (BEAM-C),respectively.All checkers detected the known errors successfully.Conclusions The stabilities of all the four evaluated instruments met the requirements of daily QA for LINAC.LINA-C verifies CAX only.QUICKE-C,BEAM-C and QA3 can be used to perform all the daily QA protocols as suggested by AAPM TG 142 report.They also provide unique additional functions.The setup of baseline determines if the morning checkers could measure the LINAC dosimetric parameters correctly.When an error is alarmed by the morning checker,it is recommended to verify the performance of the instrument first rather than recalibrating the LINAC immediately.
4.Absolute dose calibration and output factor simulation for flattened and flattening filter-free Monte Carlo model of 6 MV photon beams
Haizhen YUE ; Yibao ZHANG ; Qiaoqiao HU ; Zhuolun LIU ; Fan JIANG ; Jian GONG ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2017;37(1):29-34
Objective To explore the Monte Carlo calculation methods for the absolute dose calibration and output factor of 6 MV flattening-filter ( FF) and flattening-filter free ( FFF) photon beams based on TrueBeam accelerator .Methods The BEAMnrc code was used to model the LINAC head of FF and FFF modes.The BEAM_up covers the components from the target to the monitor chamber , and BEAM_down includes the structures beneath the chamber , the dose deposit to the monitor chamber contributed by the incidence electrons and scattered particles from the secondary collimators were calculated respectively .The incidence electron-induced dose at certain depths on the central axis were simulated by means of the DOSXYZnrc code .By means of dose calibration equation , the calibration factor for the standard field (10 cm ×10 cm) and the output factors for various fields (1 cm ×1 cm-40 cm ×40 cm) were computed respectively .Results For the 6 MV FF and FFF beams under the standard 10 cm ×10 cm field, 1 MU equals to 7.747 ×1013 ±3.099 ×1011 and 3.248 ×1013 ±1.624 ×1011 electrons to the target , respectively , which deposited 21.53 and 35.01 cGy to the monitor chamber of the virtual accelerator respectively .The difference between the simulated and calculated output factors were 0.72%±1.4%and 0.56%±0.78%for FF and FFF , respectively .Conclusions The model generated and measured output factors agree well , indicating the good accuracy of the dose calculation by the model , which would provides basis for further clinical dosimetric studies .
5.Application of fluorescent targeted retroperitoneal lymph node dissection in the treatment of lymph node recurrence after radical prostatectomy
Yu WANG ; Weicong LIANG ; Zhuolun SUN ; Jinming DI ; Xiaopeng LIU ; Tengcheng LI ; Ke LI ; Xingqiao WEN ; Xin GAO
Chinese Journal of Urology 2021;42(9):666-669
Objective:To explore the efficacy of fluorescent retroperitoneal lymph node dissection in the comprehensive treatment of lymph node recurrence after radical prostatectomy (RP).Methods:From January 2017 to December 2020, 25 patients with lymph node recurrence diagnosed by 68Ga-PSMA PET/CT after RP in our hospital were enrolled in this study. The patients were 67 (59-77) years old. The median PSA was 7.7 (0.5-12.6) ng/ml at lymph node recurrence, and was treated with androgen deprivation therapy (ADT), suggesting hormone-sensitive prostate cancer. Before recurrence, 4 cases were in T 2 stage, 17 cases in T 3, 4 cases in T 4, 10 cases in N 0, and 15 cases in N 1stage, 25 cases in M 0stage. 2 cases diagnosed as ISUP grade group <3, 9 cases in group 4, and 14 cases in group 5. The median time from radical resection to recurrence was 43 (27-56) months. All 25 cases were diagnosed as lymph node recurrence by 68Ga-PSMA PET/CT examination. Fluorescence retroperitoneal lymph node dissection was performed. Pelvic lymph nodes were detected in the dark field under the fluorescence mode, and positive lymph nodes were found. The white light mode was switched, and the lymph nodes were cleaned, and recorded. For metastatic lymph nodes indicated by preoperative PSMA PET/CT, routine dissection was performed regardless of whether the lymph nodes were fluorescently positive or not. The only routine examination was performed if there were no lymph nodes with fluorescently positive staining in other sites. Perioperative data, biochemical recurrence (BCR) rate, radiological recurrence (RAR) rate, and follow-up data were collected and analyzed. Results:25 patients were pathologically diagnosed with lymph node metastasis. The median lymph node dissection time was 21(15-28) min, estimated blood loss was 30(20-50) ml, hospital days was 4(3-5)d without any severe complications (
6.State of the art of gel dosimeters for three-dimensional radiotherapy dose verification
Yi DU ; Ruoxi WANG ; Haizhen YUE ; Zhuolun LIU ; Jian ZHANG ; Qiaoqiao HU ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2019;39(7):544-548
Dose verification, as part of the radiotherapy QA chain, is a significant method to ensure the patients' safety and efficacy of treatment. The increasing application of precision radiotherapy techniques in clinic has advanced the need of three-dimensional ( 3D) dose verification. Gel dosimeters, prevailing for its intrinsic 3D high-resolution measurement and good tissue equivalence, can serve as effective supplement to the clinical radiotherapy dosimetric system. This paper reviews the method ology, dose response mechanism, characterizations of the state-of-the-art gel dosimeters. Gel dosimeters, outstanding for 3D dose measurement, have a great potential to explore both for clinical application and academic research.
7.Impact of immobilization base plates composed of various materials on the imaging quality of MR simulation during radiotherapy
Qiaoqiao HU ; Zhuolun LIU ; Jian ZHANG ; Sha LI ; Haizhen YUE ; Meijiao WANG ; Tian LI ; Sunjun JIN ; Yibao ZHANG
Chinese Journal of Radiation Oncology 2018;27(4):410-415
Objective To compare the impact of immobilization base plates composed of 7 types of materials on the MR-simulation imaging quality used for radiotherapy,aiming to provide reference data for clinical applications.Methods Using identical T1 and T2 sequences of Siemens MR-simulator,the MR images of ACR Large Phantom were acquired on the Orfit carbon fiber laminate,polycarbonate (PC),high precision base plate (HP),Jinan Huayuxin BR,WR,KP and SP materials,respectively.The imaging quality without any plate was used as the baseline data.The following metrics were compared:1.High-contrast spatial resolution:the sharpness of 3 pairs of hole arrays was observed,which represented resolutions of 1.1 mm,1.0 mm and 0.9 mm on the LR and AP directions;2.Image intensity uniformity in terms of percent integral uniformity (PIU):PIU =100× [1-((high-low)/(high +low)];3.Low-contrast resolution:distinguishable spokes representing resolutions of 5.1%,3.6%,2.5% and 1.4% were recorded.According to ACR recommendations,high-contrast resolution of 1.0 mm,PIU of T1WI and T2>82%and low-contrast spoke difference<3 were considered as clinically acceptable.Results High-contrast T1WI and T2WI resolutions of no plate,PC plate,HP plate and KP material were all 0.9 mm,and those of the remaining materials were =worse than 0.9 mm.The T1WI and T2WI PIU of no plate was>87%,and the PIU of carbon fiber plate was reduced by> 25%.The PIU decrease of remaining materials was within ±4%.Except the carbon fiber plate,the low-contrast spokes of the remaining materials were within ±3 compared with the reference.Conclusions In clinical settings,carbon fiber plate exerts the most significant effect upon the MR-simulation imaging quality,which is unsuitable for MR simulation.Imaging quality of PC and HP plates are consistent with that of no plate.BR and KP materials exert slight effect upon MR signal.The remaining materials are of potential values for the manufacture of immobilization devices and accessories.
8.Study on the Protective Effects of Schisandrin A on Hepatic Fibrosis Induced by Carbon Tetrachloride in Mice and Its Mechanism
Xiaohui WANG ; Lin ZHOU ; Qiuzheng DU ; Yingying SHI ; Ziwei JING ; Liwei LIU ; Jun ZHANG ; Zhuolun LI ; Xuedong JIA ; Yaojuan CHU ; Zhi SUN ; Lihua ZUO ; Jian KANG ; Xiaojian ZHANG
China Pharmacy 2020;31(22):2725-2730
OBJECTIVE:To study the pr otective effect of schisandrin A (SA)on CCl 4-induced liver fibrosis model mice and its mechanism. METHODS :Mice were randomly divided into blank control group ,model group ,silymarin group (positive control,100 mg/kg),SA low-dose and high-dose groups (20,40 mg/kg),with 10 mice in each group. Except for blank control group,other groups were given CCl 4 subcutaneously to induce liver fibrosis model. After successful modeling ,administration groups were given relevant medicine intragastrically ,once a day ,for consecutive 6 weeks;blank control group and model group were given constant volume of 0.5%sodium carboxymethyl cellulose solution intragastrically by the same way. HE staining was used to observe the pathological changes of liver tissue in mice. UV spectrophotometry and ELISA assay were adopted to detect the serum levels of liver injury indexes (ALT and AST )and the contents of inflammatory factors (TNF-α,IL-1β,IL-6). Western blotting assay was used to detect the expression of NOD like receptor protein 3(NLRP3)/NF-κB and TGF-β/Smad signaling pathway protein. RESULTS :Compared with blank control group ,obvious pathological changes of liver fibrosis were observed in model group. The serum levels of liver injury indexes and contents of inflammatory factors were significantly increased (P<0.01). The expression of NLRP 3,apoptosis associated spot-like protein ,Caspase-1 and IL- 1β,TGF-β1 and ratios ofp-NF-κB p65/NF-κB p65,p-IκBα/IκBα,p-Samd3/Smad3 were increased significantly (P<0.01). Compared with model group ,SA could significantly relieve hepatic fibrosis in mice ,reduce serum levels of liver injury indexes and contents of inflammatory factors ,as well as the expression of NLRP 3/NF-κB and TGF-β/Smad signaling pathway protein and phosphorylation level(P<0.01). CONCLUSIONS : SA can effectively relieve liver injury and inflammation of CCl 4-induced hepatic fibrosis model mice ,which may be through the regulation of NLRP 3/NF-κB and TGF-β/Smad3 signaling pathways ,thus inhibiting the process of liver fibrosis.